You're using an outdated browser. This website will not display correctly and some features will not work.
Learn more about the browsers we support for a faster and safer online experience.

O. Reg. 762/20: BUILDING CODE

filed December 16, 2020 under Building Code Act, 1992, S.O. 1992, c. 23

Skip to content

 

ontario regulation 762/20

made under the

Building Code Act, 1992

Made: December 16, 2020
Filed: December 16, 2020
Published on e-Laws: December 17, 2020
Printed in The Ontario Gazette: January 2, 2021

Amending O. Reg. 332/12

(BUILDING CODE)

1. Clause 1.4.1.3.(1)(a) of Division A of Ontario Regulation 332/12 is amended by adding the following Subclause:

(0.0.i) section 3 of the Building Transit Faster Act, 2020 with respect to the issuance of a permit under that section,

2. Item 106 of Table 1.3.1.2. of Division B of the Regulation is revoked.

3. Table 1.3.2.1. of Division B of the Regulation is amended by adding the following Items:

4.1

ASCE

American Society of Civil Engineers

. . . . .

22.1

GRHC

Green Roofs for Healthy Cities

.  . . . .

23.1

HPVA

Hardware Plywood & Veneer Association

. . . . .

35.1

SEI

Structural Engineering Institute

.  . . . .

36.1

SPRI

Single Ply Roofing Industry

4. Sentences 3.1.9.3.(6) and (7) of Division B of the Regulation are revoked.

5. Table 4.1.6.10. of Division B of the Regulation is amended by striking out:

Item

Column 1

Load Case

Column 2

Range of application

Column 3

Arch Roofs, Curved Roofs and Domes

Cw

Column 4

Arch Roofs, Curved Roofs and Domes

Ca - Upwind Side

Column 5

Arch and Curved Roofs

Ca - Downwind Side

Column 6

Domes

Ca - Downwind Side

and substituting:

Item

Column 1

Load Case

Column 2

Range of application

Column 3

Factors - Arch Roofs, Curved Roofs and Domes

Cw

Column 4

Factors - Arch and Curved Roofs

Ca - Upwind Side

Column 5

Factors - Arch and Curved Roofs

Ca - Downwind Side

Column 6

Factors - Domes

Ca - Downwind Side

6. Sentence 4.1.7.4.(2) of Division B of the Regulation is amended by striking out “” and substituting “”.

7. Sentence 4.1.7.8.(4) of Division B of the Regulation is amended by,

(a) striking out “x0 = (1 222 fn/VH)” and substituting “x0 = (1 220 fn/VH)”; and

(b) striking out “” and substituting “”.

8. Sentence 4.1.8.2.(1) of Division B of the Regulation is amended by adding the following:

Ts = fundamental lateral period of vibration of the building or structure in seconds in the direction under consideration, as described in Sentence 4.1.8.1.(7),

9. Item 5 of Table 4.1.8.4.H. of Division B of the Regulation is amended by striking out “0.87” in Column 4 and substituting “0.98”.

10. Clause 4.1.8.10.(2)(a) of Division B of the Regulation is amended by striking out “Types 1, 3, 4, 5 and 7” and substituting “Types 1, 3, 4, 5, 7 and 9”.

11. (1) Tables 4.1.8.11.A., 4.1.8.11.B., 4.1.8.11.C., 4.1.8.11.D. and 4.1.8.11.E. of Division B of the Regulation are amended by,

(a) striking out “Sa(0.2)/Sa(5.0)” in the heading to Column 1 of each Table and substituting in each case “S(0.2)/S(5.0)”; and

(b) striking out “S(0.2)/S(0.5)” in Note 1 to each Table and substituting in each case “S(0.2)/S(5.0)”.

(2) Item 1 of Table 4.1.8.11.B. of Division B of the Regulation is amended by striking out “1” in Column 5 and substituting “1(6)”.

12. Clause 9.33.1.2.(2)(b) of Division B of the Regulation is amended by striking out “November 1, 2013” at the end and substituting “March 16, 2015”.

13. (1) Sentence 1.3.1.5.(1) of Division C of the Regulation is amended by adding the following Clause:

(0.a) section 3 of the Building Transit Faster Act, 2020 with respect to the issuance of a permit under that section,

(2) Sentences 1.3.1.5.(3.1) and (3.2) of Division C of the Regulation are revoked.

Commencement

14. This Regulation comes into force on the day it is filed.

Made by:

Steve Clark

Minister of Municipal Affairs and Housing

Date made: December 16, 2020