House syllabus
The Building Code
The exam covers the following sections of the Building Code.
Division A – Compliance, Objectives and Functional Statements, as follows:
- Part 1 – General:
- except 1.3.3.1A. Application of Part 2
- except 1.3.3.5.(1)(b), (c), (d), (e), (i), (j) & (k) Designated Structures
- Part 2 – Objectives
- Part 3 – Functional Statements
Division B – Acceptable Solutions, as follows:
- Part 1 – General
- Part 3 – Fire Protection, Occupant Safety and Accessibility, only:
- 3.1. General, only:
- 3.1.4.7. Heavy Timber Construction
- 3.1.5.1. Noncombustible Materials
- 3.1.5.6. Combustible Components for Exterior Walls
- 3.1.5.15.(2)(e) Foamed Plastic Insulation
- 3.1.8.4. Determination of Ratings and Classifications
- 3.1.8.10. Installation of Fire Dampers
- 3.1.9.4.(4) Combustible Piping Penetrations
- 3.1.10. Firewalls
- 3.1.12.1. Determination of Ratings
- 3.1.13.4. Light Diffusers and Lenses
- 3.1.20.1. Clearance to Buildings
- 3.2. Building Fire Safety, only:
- 3.2.1.1.(1) Exceptions in Determining Building Height
- 3.2.1.1.(3) Exceptions in Determining Building Height
- 3.2.1.1.(4) Exceptions in Determining Building Height
- 3.2.1.1.(5) Exceptions in Determining Building Height
- 3.2.1.1.(7) Exceptions in Determining Building Height
- 3.2.1.2. Storage Garage Considered as a Separate Building
- 3.2.1.3. Roof Considered as a Wall
- 3.2.1.4. Floor Assembly over Basement
- 3.2.2.1. Application
- 3.2.2.3. Exceptions to Structural Fire Protection
- 3.2.2.5. Applicable Building Height and Area
- 3.2.2.9. Crawl Spaces
- 3.2.2.10. Streets
- 3.2.2.11. Exterior Balconies
- 3.2.2.12. Exterior Passageways
- 3.2.2.13. Occupancy on Roof
- 3.2.2.14. Rooftop Enclosure
- 3.2.2.18. Automatic Sprinkler System Required
- 3.2.2.54. Group C, up to 3 Storeys
- 3.2.3.1. Limiting Distance and Area of Unprotected Openings
- 3.2.3.2.(1) Area of Exposing Building Face
- 3.2.3.2.(2) Area of Exposing Building Face
- 3.2.3.3. Wall Enclosing Attic or Roof space
- 3.2.3.5. Wall with Limiting Distance Less Than 1.2m
- 3.2.3.6. Combustible Projections
- 3.2.3.7. Construction of Exposing Building Face
- 3.2.3.8. Protection of Exterior Building Face
- 3.2.3.9. Protection of Structural Members
- 3.2.3.10.(2) Unlimited Unprotected Openings
- 3.2.3.12. Area Increase for Unprotected Openings
- 3.2.3.19.(1) Walkway between Buildings
- 3.2.3.19.(5) Walkway between Buildings
- 3.2.3.20. Underground Walkway
- 3.2.4. Fire Alarm and Detection Systems:
- except 3.2.4.1. Determination of Requirement for a Fire Alarm System
- except 3.2.4.2.(2) Continuity of Fire Alarm System
- except 3.2.4.2.(6) Continuity of Fire Alarm System
- except 3.2.4.4.(2) Description of Fire Alarm Systems
- except 3.2.4.4.(3) Description of Fire Alarm Systems
- except 3.2.4.4.(4) Description of Fire Alarm Systems
- except 3.2.4.6.(3) Silencing of Alarm Signals
- except 3.2.4.7.(1) Signals to Fire Department
- except 3.2.4.7.(2) Signals to Fire Department
- except 3.2.4.7.(3) Signals to Fire Department
- except 3.2.4.7.(4) Signals to Fire Department
- except 3.2.4.8.(6) Annunciator and Zone Indication
- except 3.2.4.8.(8) Annunciator and Zone Indication
- except 3.2.4.8.(9) Annunciator and Zone Indication
- except 3.2.4.9.(2) Electrical Supervision
- except 3.2.4.9.(6) Electrical Supervision
- except 3.2.4.10. Fire Detectors
- except 3.2.4.11. Smoke and Heat Detectors
- except 3.2.4.12. Prevention of Smoke Circulation
- except 3.2.4.13. Vacuum Cleaning System Shutdown
- except 3.2.4.16.(6) Manual Stations
- except 3.2.4.16.(7) Manual Stations
- except 3.2.4.16.(9) Manual Stations
- except 3.2.4.17.(1) Alert and Alarm Signals
- except 3.2.4.18.(3) Audibility of Alarm Systems
- except 3.2.4.18.(11) Audibility of Alarm Systems
- except 3.2.4.18.(13) Audibility of Alarm Systems
- except 3.2.4.19. Visible Signals
- except 3.2.4.20. Smoke Alarms
- except 3.2.4.22. Two-Way Voice Communication Systems
- 3.2.5.8.(1) Standpipe Systems
- 3.2.5.9. Standpipe System Design
- 3.2.5.10.(1) Hose Connections
- 3.2.5.11. Hose Stations
- 3.2.5.12. Automatic Sprinkler Systems
- 3.2.5.13. Combustible Sprinkler Piping
- 3.2.7.8. Emergency Power for Fire Alarm Systems
- 3.2.7.10. Protection of Electrical Conductors
- 3.2.8.1.(1) Application
- 3.2.8.1.(2) Application
- 3.3. Safety Within Floor Areas, only:
- 3.3.1.21. Exhaust Ventilation and Explosion Venting
- 3.3.1.26. Welding and Cutting
- 3.4. Exits, only:
- 3.4.1.6.(1) Restricted Use of Horizontal Exits
- 3.4.2.5. Location of Exits
- 3.4.6.10. Horizontal Exits
- 3.4.7. Fire Escapes
- 3.5. Vertical Transportation, only:
- 3.5.3. Fire Separations:
- except 3.5.3.1.(2) Fire Separations for Elevator Hoistways
- except 3.5.4.1. Elevator Car Dimensions
- 3.5.3. Fire Separations:
- 3.6. Service Facilities, only:
- 3.6.3. Vertical Service Spaces and Service Facilities:
- except 3.6.3.4. Exhaust Duct Negative Pressure
- 3.6.3. Vertical Service Spaces and Service Facilities:
- 3.7. Health Requirements, only:
- 3.7.2.1.(1) Window Areas
- 3.7.4.1. Plumbing and Drainage Systems
- 3.7.4.2. Plumbing Fixtures, General
- 3.7.4.5. Plumbing Facilities for Dwelling Units
- 3.7.4.10. Glazing
- 3.7.4.11. Surface Protection
- 3.7.4.12. Floor Drains
- 3.7.4.13. Grab Bar Installation
- 3.7.4.16. Water Temperature Control
- 3.7.4.19. Plumbing Fixtures for Mobile Home Facilities
- 3.8. Barrier-Free Design, only:
- 3.8.3.8.(1)(d) Water Closet Stalls and Enclosures
- 3.8.3.13.(2)(g) Showers and Bathtubs
- 3.1. General, only:
- Part 4 – Structural Design, only:
- 4.1. Structural Loads and Procedures, only:
- 4.1.2.1. Loads and Effects
- 4.1.5.3. Full and Partial Loading
- 4.1.5.14. Loads on Guards and Handrails
- 4.1.5.17. Firewalls
- 4.2. Foundations:
- except 4.2.3.8. Steel Piles
- except 4.2.3.9. High Strength Steel Tendons
- except 4.2.4.2. Subsurface Investigation
- except 4.2.4.4. Depth of Foundations
- except 4.2.4.7. Dynamic Loading
- except 4.2.4.9. Groundwater Level Change
- except 4.2.5.1. Design of Excavations
- except 4.2.5.2. Excavation Construction
- except 4.2.5.3. Supported Excavations
- except 4.2.5.4. Unsupported Excavations
- except 4.2.5.5. Control of Water Around Excavations
- except 4.2.5.6. Loss of Ground
- except 4.2.7. Deep Foundations
- except 4.2.8. Special Foundations
- 4.3. Design Requirements for Structural Materials
- 4.1. Structural Loads and Procedures, only:
- Part 5 – Environmental Separation:
- except 5.4. Air Leakage
- except 5.7. Surface and Ground Water
- except 5.8. Sound Transmission
- Part 6 – Heating, Ventilating and Air- Conditioning, only:
- 6.2. Design and Installation, only:
- 6.2.1.5.(1) Installation Standards
- 6.3. Ventilation Systems, only
- 6.3.2.9. Supply, Return, Intake and Exhaust Air Openings
- 6.3.2.10.(7) Exhaust Ducts and Outlets
- 6.2. Design and Installation, only:
- Part 7 – Plumbing, only:
- 7.1. General, only:
- 7.1.2.1. Sanitary Drainage Systems
- 7.1.2.2. Storm Drainage Systems
- 7.2. Materials and Equipment, only:
- 7.2.10.7B. Showers
- 7.4. Drainage Systems, only:
- 7.4.10.4. Hydraulic Loads from Roofs or Paved Surfaces
- 7.6. Potable Water Systems, only:
- 7.6.1.7. Relief Valves
- 7.6.4. Water Efficiency
- 7.1. General, only:
- Part 9 – Housing and Small Buildings, only:
- 9.1. General, only:
- 9.1.1.1. Application
- 9.1.1.5. Proximity to Existing Above Ground Electrical Conductors
- 9.1.1.7. Radon
- 9.1.1.8. Building in Flood Plains
- 9.1.1.9. Site Assembled and Factory-Built Buildings
- 9.3. Materials, Systems and Equipment
- 9.4. Structural Requirements
- 9.5. Design of Areas, and Spaces and Doorways:
- except 9.5.2.2. Protection on Floor Areas with a Barrier- Free Path of Travel
- except 9.5.3D.5. Recreational Camps
- except 9.5.3D.6. Camps for Housing Workers
- except 9.5.5.2. Doors to Public Water Closet Rooms
- 9.6. Glass:
- except 9.6.1.4.(4) Types of Glass and Protection of Glass
- except 9.6.1.4.(5) Types of Glass and Protection of Glass
- 9.7. Windows, Doors and Skylights
- 9.8. Stairs, Ramps, Handrails and Guards:
- except 9.8.1.4. Escalators and Moving Walks
- except 9.8.5.1.(2) Application
- except 9.8.6.1.(2) Application
- except 9.8.8.1.(8) Required Guards
- except 9.8.8.4. Guards for Floors and Ramps in Garages
- 9.9. Means of Egress:
- except 9.9.2.6. Exterior Exit Stairs that Serve a Hotel
- except 9.9.4.7. Stairways in Group D or E Buildings
- except 9.9.5.2. Occupancies in Corridors
- except 9.9.6.4.(2) Door Action
- except 9.9.6.4.(3) Door Action
- except 9.9.6.4.(4) Door Action
- except 9.9.6.5.(1.1) Direction of Door Swing
- except 9.9.6.5.(2) Direction of Door Swing
- except 9.9.6.5.(3) Direction of Door Swing
- except 9.9.6.5.(4) Direction of Door Swing
- except 9.9.8.2.(3) Number of Required Exits
- except 9.9.8.5. Exiting through a Lobby
- except 9.9.8.6. Mezzanine Means of Egress
- except 9.9.11.3. Exit Signs
- 9.10 Fire Protection:
- except 9.10.1.3.(2) Items Under Part 3 Jurisdiction
- except 9.10.2.3. Major Occupancies above Other Major Occupancies
- except 9.10.2.4. Buildings Containing More Than One Major Occupancy
- except 9.10.8.8.(2) Floors of Exterior Passageways
- except 9.10.9.5. Interconnected Floor Spaces
- except 9.10.9.15. Separation of Suites
- except 9.10.9.17.(2) Separation of Public Corridors
- except 9.10.9.17.(3) Separation of Public Corridors
- except 9.10.9.19.(2) Separation of Repair Garages
- except 9.10.9.19.(4) Separation of Repair Garages
- except 9.10.10.5. Incinerators
- except 9.10.13.10.(2) Self- Closing Device
- except 9.10.17.7. Corridors Containing an Occupancy
- except 9.10.17.8. Light Diffusers and Lenses
- except 9.10.18.4.(4) Rooms and Spaces Requiring Heat Detectors or Smoke Detectors
- except 9.10.18.6. Portions of Buildings Considered as Separate Buildings
- except 9.10.18.8. Open-Air Storage Garages
- except 9.10.18.9. Fire Alarm System in a Hotel
- except 9.10.20.4. Portable Extinguishers
- except 9.10.20.5. Freeze Protection for Fire Protection Systems
- except 9.10.21. Fire Protection for Construction Camps
- 9.11. Sound Transmission
- 9.12. Excavation
- 9.13. Dampproofing, Waterproofing and Soil Gas Control
- 9.14. Drainage
- 9.15. Footings and Foundations
- 9.16. Floors-On-Ground
- 9.17. Columns
- 9.18. Crawl Spaces
- 9.19. Roof Spaces
- 9.20. Masonry and Insulating Concrete Form Walls Not in Contact with the Ground
- 9.21. Masonry and Concrete Chimneys and Flues
- 9.22. Fireplaces
- 9.23. Wood- Frame Construction
- 9.24. Sheet Steel Stud Wall Framing
- 9.25. Heat transfer, Air Leakage and Condensation Control
- 9.26. Roofing
- 9.27. Cladding
- 9.28. Stucco
- 9.29. Interior Wall and Ceiling Finishes
- 9.30. Flooring
- 9.31. Plumbing Facilities:
- except 9.31.1.1.(2) Application
- except 9.31.1.1.(3) Application
- 9.33. Heating and Air-Conditioning, only:
- 9.33.6.14A.(3) Exhaust Ducts and Outlets
- 9.34. Electrical Facilities:
- except 9.34.1.5. Wiring and Cables
- 9.35. Garages and Carports
- 9.37. Cottages
- 9.38. Log Construction
- 9.39. Park Model Trailers
- 9.40. Reinforced Concrete Slabs
- 9.41. Additional requirements for Change of Use
- 9.1. General, only:
- Part 11 – Renovation, only:
- 11.5. Compliance Alternatives, including Compliance Alternatives listed in Tables
- Tables 11.5.1.1.C which cross-reference requirements in the remainder of the “House” syllabus
- Part 12 – Resource Conservation and Environmental Integrity, only:
- 12.1. General
- 12.2. Energy Efficiency, Carbon Dioxide Equivalents and Peak Electric Demand:
- except 12.2.1.2.(2) Energy Efficiency Design
- except 12.2.1.2.(4) Energy Efficiency Design
- except 12.2.2.1.(1) Carbon Dioxide Equivalents
- except 12.2.3.1.(1) Peak Electric Demand
- 12.3. Energy Efficiency for Buildings of Residential Occupancy Within the Scope of Part 9
- 12.4. Water Efficiency
Division C – Administrative Provisions, only:
- Part 1 – General, only:
- 1.1.1.2. Conformance with Administrative Requirements
- 1.2.1.1.(1) Application
- 1.3. Permits and Inspections, only:
- 1.3.1.5. Conditional Permits
- 1.3.2.1. Permit Posting
- 1.3.2.2. Documentation on Site
- 1.3.3.2. Conditions for Residential Occupancy
- 1.3.3.3. Notification
- 1.3.3.4. Occupancy Permit – Certain Buildings of Residential Occupancy
- 1.3.5.1.(1) Prescribed Notices
- 1.3.5.1.(2)(a) to (i), (o) and (p) Prescribed Notices
- 1.3.5.2. Additional Notices
- 1.3.6.1. Application
- Part 2 – Alternative Solutions, Disputes, Rulings and Interpretations, only:
- 2.1. Alternative Solutions
- 2.4. Rulings and Interpretations
Supplementary Standards
The following Supplementary Standards may be covered in the exam:
- Supplementary Standard SA-1 – Objectives and Functional Statements Attributed to the Acceptable Solutions
- Supplementary Standard SB-1 – Climatic and Seismic Data
- Supplementary Standard SB-2 – Fire Performance Ratings
- Supplementary Standard SB-3 – Fire and Sound Resistance Tables
- Supplementary Standard SB-7 – Guards for Housing and Small Buildings
- Supplementary Standard SB-9 – Requirements for Soil Gas Control
- Supplementary Standard SB-12 – Energy Efficiency for Housing