Plumbing - All buildings syllabus
The Building Code
The exam covers the following sections of the Building Code.
Division A – Compliance, Objectives and Functional Statements, as follows:
- Part 1 – Compliance:
- except 1.3.3.1A. Application of Part 2
- except 1.3.3.2. Application of Parts 3, 4, 5 and 6
- except 1.3.3.2A. Application of Part 8
- except 1.3.3.3. Application of Part 9
- except 1.3.3.3A. Application of Part 10
- Part 2 – Objectives
- Part 3 – Functional Statements
Division B – Acceptable Solutions, as follows:
- Part 1 – General:
- except 1.1.3.2. Depth of Frost Penetration
- Part 3 – Fire Protection, Occupant Safety and Accessibility, only:
- 3.1. General, only:
- 3.1.5.19.(1) Combustible Piping Materials
- 3.1.5.19.(3) Combustible Piping Materials
- 3.1.5.20. Combustible Plumbing Fixtures
- 3.1.5.26. Combustible Components in Public Pools and Public Spas
- 3.1.9.1.(1) Firestops
- 3.1.9.1.(2) Firestops
- 3.1.9.1.(3) Firestops
- 3.1.9.2. Service Equipment Penetrations
- 3.1.9.4. Combustible Piping Penetrations
- 3.1.9.6. Plenums
- 3.1.10.1.(4) Prevention of Firewall Collapse
- 3.1.11.2.(2) Fire Blocks in Wall Assemblies
- 3.1.11.7.(7) Fire Block Materials
- 3.1.12.1. Determination of Ratings
- 3.1.13.3.(2) Bathrooms in Residential Suites
- 3.1.13.7.(5) High Buildings
- 3.1.13.7.(6) High Buildings
- 3.1.13.7.(7) High Buildings
- 3.1.13.7.(8) High Buildings
- 3.4. Exits, only:
- 3.4.4.4.(1) Integrity of Exits
- 3.4.4.4.(8) Integrity of Exits
- 3.6. Service Facilities, only:
- 3.6.2.7.(15) Electrical Equipment Vaults
- 3.6.3.1.(5) Fire Separations for Vertical Service Spaces
- 3.6.3.3.(1) Linen and Refuse Chutes
- 3.6.3.3.(8) Linen and Refuse Chutes
- 3.6.3.3.(10) Linen and Refuse Chutes
- 3.6.4.3. Plenum Requirements
- 3.7. Health Requirements, only:
- 3.7.4. Plumbing Facilities
- 3.7.6.1. Application
- 3.7.6.3. Location of Plumbing Fixtures
- 3.7.6.4. Lavatories, Appliances and Sinks
- 3.7.6.5. Hot and Cold Water Supply
- 3.7.6.6.(2) Employee Facilities
- 3.8. Barrier-Free Design, only:
- 3.8.2.3. Washrooms Required to be Barrier-Free
- 3.8.3.8. Water Closet Stalls and Enclosures
- 3.8.3.9. Water Closets
- 3.8.3.11. Lavatories, Mirrors and Washroom Accessories
- 3.8.3.12. Universal Washrooms
- 3.8.3.13. Showers and Bathtubs
- 3.8.3.16. Drinking Fountains
- 3.9. Portable Classrooms, only:
- 3.9.3.8. Washroom Facilities
- 3.10. Self-Service Storage Buildings, only:
- 3.10.2.7. Sanitary Facilities
- 3.11. Public Pools, only:
- 3.11.3.1.(16) Construction Requirements
- 3.11.3.1.(17) Construction Requirements
- 3.11.3.1.(18) Construction Requirements
- 3.11.5.1.(3) Ramps into Public Pools
- 3.11.6.1.(7) Construction Requirements
- 3.11.8.1.(2) Recirculation Systems
- 3.11.8.1.(3) Recirculation Systems
- 3.11.8.1.(6) Recirculation Systems
- 3.11.8.1.(7) Recirculation Systems
- 3.11.8.1.(9) Recirculation Systems
- 3.11.8.1.(10) Recirculation Systems
- 3.11.8.1.(11) Recirculation Systems
- 3.11.8.1.(13) Recirculation Systems
- 3.11.8.1.(16) Recirculation Systems
- 3.11.8.1.(20) Recirculation Systems
- 3.11.9.1.(1) Dressing Rooms and Sanitary Facilities
- 3.11.9.1.(2) Dressing Rooms and Sanitary Facilities
- 3.11.9.1.(3) Dressing Rooms and Sanitary Facilities
- 3.11.9.1.(4) Dressing Rooms and Sanitary Facilities
- 3.11.9.1.(5) Dressing Rooms and Sanitary Facilities
- 3.11.9.1.(6) Dressing Rooms and Sanitary Facilities
- 3.11.9.1.(7) Dressing Rooms and Sanitary Facilities
- 3.11.9.1.(8) Dressing Rooms and Sanitary Facilities
- 3.11.9.1.(9) Dressing Rooms and Sanitary Facilities
- 3.11.9.1.(11) Dressing Rooms and Sanitary Facilities
- 3.11.11.1.(4) Service Rooms and Storage Facilities
- 3.12. Public Spas, only:
- 3.12.4.1.(18) Water Circulation Systems
- 3.12.6. Service Rooms and Storage for All Public Spas
- 3.13. Rapid Transit Stations, only:
- 3.13.5.11.(7) Standpipe and Hose Systems
- 3.13.6. Required Sanitary Facilities
- 3.13.8.5. Washrooms Required to be Barrier-Free
- 3.14. Tents and Air-Supported Structures, only:
- 3.14.1.8. Sanitary Facilities
- 3.18. Additional Requirements for Existing Buildings, only:
- 3.18.1.1.(1) Application
- 3.18.1.1.(3) Application
- 3.18.2.1.(1) Change of Use and Compensating Construction
- 3.18.2.2.(1) Performance Level and Compensating Construction
- 3.1. General, only:
- Part 7 – Plumbing
- Part 9 – Housing and Small Buildings, only:
- 9.1. General, only:
- 9.1.1.9. Site Assembled and Factory-Built Buildings
- 9.1.1.10. Public Pools and Public Spas
- 9.6. Glass, only:
- 9.6.1.1. Application
- 9.6.1.2.(1) Material Standards for Glass
- 9.6.1.4.(6) Types of Glass and Protection of Glass
- 9.9. Means of Egress, only:
- 9.9.4.2.(3) Fire Separation for Exits
- 9.9.4.2.(4) Fire Separation for Exits
- 9.9.5.7. Fuel- Fired Appliances
- 9.9.5.8. Service Rooms
- 9.9.5.9. Ancillary Rooms
- 9.10. Fire Protection, only:
- 9.10.1.3.(7) Items Under Part 3 Jurisdiction
- 9.10.5.1.(1) Permitted Openings in Wall and Ceiling Membranes
- 9.10.9.6. General Requirements for Penetrations of Fire Separations
- 9.10.9.7. Piping Penetrations
- 9.10.9.8. Penetrations by Outlet Boxes or Service Equipment in Concealed Spaces
- 9.10.9.9. Penetrations by Raceways, Sprinklers and Fire Dampers
- 9.10.16.4. Penetration of Fire Blocks
- 9.14. Drainage, only:
- 9.14.1. Scope
- 9.14.3. Drainage Tile and Pipe
- 9.14.4.3. Grading
- 9.14.4.4. Wet Site Conditions
- 9.14.5. Drainage Disposal
- 9.14.6.2. Drainage away from Wells or Septic Disposal Beds
- 9.14.6.4. Catch Basin
- 9.23. Wood Frame Construction, only:
- 9.23.5. Notching and Drilling
- 9.26. Roofing, only:
- 9.26.18.1. Roof Drains
- 9.27. Cladding, only:
- 9.27.4.1.(1) Required Sealants
- 9.27.4.2. Materials
- 9.31. Plumbing Facilities
- 9.36.1.1. Application
- 9.37. Cottages, only:
- 9.37.1.1. Application
- 9.37.2.1.(3) Exclusions
- 9.39. Park Model Trailers, only:
- 9.39.1.1. Application
- 9.39.2.1. General
- 9.39.3.1. Other Building Components
- 9.41. Additional Requirements for Change of Use
- 9.1. General, only:
- Part 11 – Renovation, only:
- 11.5. Compliance Alternatives, including Compliance Alternatives listed in Tables
- Tables 11.5.1.1.-A, 11.5.1.1.-B, 11.5.1.1.-C, 11.5.1.1.-D/E, and 11.5.1.1.-F. which cross-reference requirements in the remainder of the “Plumbing – All Building” syllabus.
- Part 12 – Resource Conservation and Environmental Integrity, only:
- 12.1. General
- 12.3. Energy Efficiency for Buildings of Residential Occupancy Within the Scope of Part 9, only:
- 12.3.1.1. Application
- 12.3.1.4. Hot Water Piping Insulation
- 12.4. Water Efficiency
Division C – Administrative Provisions, as follows:
- Part 1 – Administrative Provisions, only:
- 1.1. Application, only:
- 1.1.1.2. Conformance with Administrative Requirements
- 1.3. Permits and Inspections, only:
- 1.3.1.1.(1) Requirement for Permits
- 1.3.1.4.(1) Permits Under Section 10 of the Act
- 1.3.1.5.(1) Conditional Permits
- 1.3.2.1. Permit Posting
- 1.3.2.2. Documentation of Site
- 1.3.3.2. Conditions for Residential Occupancy
- 1.3.3.3. Notification
- 1.3.3.4. Occupancy Permit – Certain Buildings of Residential Occupancy
- 1.3.5.1.(2)(i), (k) & (n) Prescribed Notices
- 1.3.6. As Constructed Plans
- 1.1. Application, only:
- Part 2 Alternative Solutions, Disputes, Rulings and Interpretations, only:
- 2.1. Alternative Solutions
- 2.4. Rulings and Interpretations
Supplementary Standards
The following Supplementary Standards may be covered in the exam:
- Supplementary Standard SA-1 – Objectives and Functional Statements Attributed to the Acceptable Solutions
- Supplementary Standard SB-1 – Climatic and Seismic Data
Updated: January 21, 2026
Published: January 12, 2026