Volume 1 — Index
Index (1)
Items contained in the Index are referenced to the numbering system used in this Code instead of to page numbers. References occur in Division B unless noted as follows:
- [A] - references occur in Division A
- [C] - references occur in Division C
A
Abbreviations
Access
- attic or roof space, 3.6.4.4. , 9.19.2.1.
- crawl spaces, 3.6.4.6. , 9.18.2.1. , 9.18.4.1.
- chimneys, 6.3.3.4.
- fire dampers, 3.1.8.7.
- hatchways to roof, 9.19.2.1.
- heating, ventilating and air-conditioning equipment, 6.2.1.6. , 9.18.4.1. , 9.32.3.2. , 9.33.4.4.
- horizontal service spaces, 3.6.4.5. , 9.18.2.1. , 9.18.4.1.
Access for firefighting, 3.2.2.10. , 3.2.2.15. , 3.2.5.1. , 3.2.5.2. , 3.2.5.4. – 3.2.5.6. , 9.10.20.1. – 9.10.20.3.
- basements, 3.2.5.2. , 9.10.20.2.
- roof area, 3.2.5.3.
Access openings,
- Access panels, 3.2.5.1. , 9.10.20.1.
- Access route, 3.2.2.10. , 3.2.5.4. – 3.2.5.6. , 9.10.20.3.
Access to exit, 1.4.1.2. [A], 3.3.1.2. , 3.3.1.11. , 3.3.1.13. , 3.3.1.17. , 3.3.1.20. , 3.3.2.6. , 3.3.2.7. , 3.3.4.4. , 3.4.1.3. , 3.4.6.16. , 9.9.7.
- capacity, 3.3.1.17. , 9.9.3.
- corridor width, 3.3.1.9. , 9.9.3.3.
- doors in, 3.3.1.11. – 3.3.1.13. , 3.3.2.6. , 3.3.4.5. , 9.9.6.
- doors, sliding, 3.3.1.12.
- doors, transparent, 3.3.1.20.
- dwelling units, 9.9.9.
- emergency lighting in, 3.2.7.3. , 9.9.12.3.
- flame-spread rating, 3.1.13. , 9.10.21.6.
- floor areas (within), 3.3.1.3.
- headroom clearance, 3.3.1.8. , 9.9.3.4.
- illumination, 3.2.7.1. , 9.9.12.2.
- independent access to, 9.9.7.5.
- lighting, 9.9.12.2.
- podiums, terraces, platforms and contained open spaces, 9.9.7.1.
- residential occupancy, 3.3.4.4. , 9.9.9.
- roofs (from), 3.3.1.3. , 3.4.2.1.
- service rooms, 9.9.7.5.
- suites, 9.9.7.2.
- shelf and rack storage system in, 3.16.1.7.
- stairs, 3.4.6.8.
- transparent panels, 3.3.1.20.
- travel distance, 9.9.7.6.
- when exits are means of egress, 9.9.7.
- width, 9.9.3.
Access for firefighting
- Accessibility (see Barrier-free)
- Accessible change space, 3.8.3.12.
- Accessibility of fixtures and equipment, 7.1.3.2.
- Acrylonitrile-butadiene-styrene (ABS) pipe and pipe fittings, 7.2.5.9. - 7.2.5.11. , 7.2.10.1. , 7.3.4.5. , 7.4.6.4.
- Adaptable seats, 3.8.2.1.
- Adaptive Technology (see Assistive listening systems)
Additional circuit vents
- Additional upgrading, Table 11.4.3.3 ., Table 11.4.3.4.-A . and Table 11.4.3.4.-B .
- Adfreezing, 1.4.1.2. [A], 4.2.4.4.
Adhesive
- ceramic wall tiles, 9.29.10.1. , 9.29.10.3.
- ducts, 3.6.5.4.
Admixtures
Aggregate
- built-up-roofing, 9.26.11.1. , 9.26.11.4.
- concrete, 9.3.1.4. , 9.3.1.7.
- mortar, 9.20.3.1. , 9.20.3.2. , 9.29.10.2.
- stucco, 9.28.2.2. , 9.28.5.1
Air
- circulation, 6.3.2.7. , 9.33.6.12. , 9.33.6.13.
- contaminants, 3.7.6.2. , 3.2.3.13. , 6.3.1.5. ,
- combustion, 6.3.2.11. , 9.33.5.3.
- distribution, 9.32.3.6. , 9.32.3.5. , 9.33.6.1
- duct systems, 6.3.2.
- flow through and around insulation, 5.3.1.3. , 9.19.1.3. , 9.25.2.3. , 9.25.2.4.
- intakes, 6.3.2.9. , 6.3.2.15.
- leakage, 5.4. ,
- leakage resistance, 5.4.1.1. , 9.13.4.2. , 9.18.6.2. , 9.25.3.1.
- make-up, 6.3.2.8. , 9.32.3.8.
- outdoor, 9.32.3.5. , 9.32.3.12.
- permeance, 5.3.1.3. , 5.5.1.2.
- recirculation, 6.3.2.10. , 9.33.6.12. , 9.33.6.13.
- return ducts, 6.3.2.11.
- supply, 9.32.3.6. , 9.32.3.5.
- tempering, 6.3.2.8. , 9.32.3.4. , 9.32.3.5. , 9.32.3.8. , 9.32.3.11.
- transfer, 5.2.1.3. , 5.4.1.1.
- Air admittance valves, 1.4.1.2. [A], 7.2.10.16. , 7.5.9.
- Air barrier assemblies, 5.4.1.1. , 5.4.1.2.
Air barrier systems, 9.25.1.1.
- airtightness, 5.4.1.1.
- assemblies in contact with the ground, 9.13.4.
- continuity, 5.4.1.2. , 9.25.3.3.
- crawl space floors, 9.18.6.2.
- definition, 1.4.1.2. [A]
- deflections, 5.2.2.1.
- environmental loads, 5.1.4.1.
- environmental separation, 5.1.1.1.
- floors-on-ground, 9.13.4. , 9.18.6.2.
- housing and small buildings, 9.25.3.
- installation, 9.25.3.3.
- material standards, 5.9.1.1. , 9.13.4.2. , 9.18.6.2. , 9.25.3.2.
- properties, 9.25.3.1. , 9.25.5.1.
- properties of, 5.4.1.1. , 9.25.3.2.
- repair garages, 9.10.9.19.
- requirement for, 5.4.1.1. , 9.25.3.1.
- storage garages, 9.10.9.18.
- walls in contact with the ground, 9.13.4.2.
- Air break, 1.4.1.2. [A], 7.3.3.11. , 7.4.2.1. , 7.4.2.3.
- Airborne sound rating, 3.3.4.6. , 5.8.1.2. , 9.11.
- Air cleaning devices, 6.3.2.14.
Air-conditioning systems and equipment, 6.1.1.2. ,
- access, 6.2.1.6.
- accommodation of structural movement, 6.2.1.4.
- cleaning, 6.2.1.6.
- cooling units, 6.6.1.1.
- design, 6.2.1. , 9.33.1.1.
- fire safety characteristics, 6.9.1.1. , 6.2.4.10.
- installation, 6.2.1. , 6.6.1.1. , 9.33.1.1. , 9.33.4. , 9.33.5.2. , 9.33.9.1
- installation standards, 6.2.1.5. , 9.33.5.2. , 9.33.6.7.
- protection from freezing, 6.2.1.6. , 9.33.4.5.
- structural movements, 6.2.1.4.
- system pressure, 6.2.1.3.
- Air contaminants, 6.3.1.5. , 6.3.2.3. , 6.3.2.9. , 6.3.2.14.
Air duct systems
- application of Code, 6.3.2.1.
- clearance of ducts and plenums, 6.3.2.6.
- connections, 6.3.2.4.
- drain pans, 6.3.2.2.
- duct coverings and linings, 6.3.2.5.
- filters, 6.3.2.13.
- interconnection, 6.3.2.7.
- makeup air, 6.3.2.8.
- materials, 6.3.2.3.
- openings, 6.8.1.2.
- supply, return, intake and exhaust air openings, 6.3.2.9.
- tape, 6.3.2.19.
- vibration isolation connectors, 6.3.2.18.
- Air filters, 6.3.2.13. , 6.8.1.3. , 9.33.6.14.
- Air gap, 1.4.1.2. [A], 7.6.2.9. , 7.7.1.1.
Air inlets (see also Air intakes)
- grilles, 6.3.2.9. , 9.33.6.10A.
- location, 6.3.2.9. , 9.33.6.10A.
Air intakes (see also Air inlets)
- area, 9.32.3.12.
- connection, 9.32.3.4. - 9.32.3.7.
- grilles, 6.3.2.9. , 9.33.6.10A.
- labeling, 9.32.3.13.
- location, 6.3.2.9. , 9.32.3.4. , 9.32.3.5. , 9.32.3.7. , 9.32.3.11. , 9.32.3.13. , 9.33.6.10A.
- protection, 9.32.3.13.
Air outlets
- area, 9.32.3.13.
- capacity, 9.33.6.11.
- design, 6.3.2.10.
- diffusers, 9.33.6.10.
- grilles, 6.3.2.9. , 9.33.6.10A. , 9.32.
- labeling, 9.32.3.13.
- location, 6.3.2.9. , 9.32.3.13. , 9.33.6.10A. , 9.33.6.11.
- warm air heating, 9.33.6.11.
- Air quality, emergency power supply, 3.2.7.9.
- Air pressure tests, 7.3.6.1. - 7.3.6.3. , 7.3.6.5. , 7.3.7.1. , 7.3.7.2.
Air-supported structures, 1.4.1.2. [A], 3.1.15.2. , 3.14.2. , 9.1.1.4. , 9.10.1.3.
- Air test, 7.3.6.1. , 7.3.6.5. , 7.3.7.1. , 7.3.7.2.
- Airborne sound rating, 3.3.4.6. , 5.9.
- Air washers, 6.3.2.16.
- Aisles, 3.3.2.5. , 3.4.2.5. , 3.4.3.2. , 3.3.2.10.
- Alarm signal, 1.4.1.2. [A], 3.2.4.4. , 3.2.4.6. , 3.2.4.15. , 3.2.4.17. , 3.2.4.18. , 3.2.4.22. , 3.2.5.14. , 3.2.6.7.
- Alert signal, 1.4.1.2. [A], 3.2.4.4. , 3.2.4.6. , 3.2.4.15. , 3.2.4.17. , 3.2.4.18. , 3.2.4.22. , 3.2.5.14. , 3.2.6.7.
Alternative solution 1.2.1.1. [A], 2.1. [C]
- definition 1.4.1.2. [A]
- Alloyed zinc, 7.2.10.14.
Aluminum
- design basis for structures, 4.3.5.1.
- flashing, 9.20.13.1. , 9.20.13.2. , 9.26.4.2. , 9.27.3.7. , 9.28.1.5.
- nails, 9.26.2.3.
- roofing, 9.26.13.1.
- siding, 9.27.11.1.
- structural design basis, 4.3.5.
- Ammonium Nitrate Storage, 3.3.6.6.
Anchorage, 4.1.3.2. , 4.1.8.2.
- anchor bolts, 9.20.11.6.
- columns, 9.23.6.2.
- concrete stairs, 9.8.10.2.
- cornices, 9.20.11.5.
- floors, 9.20.11.
- foundations (to), 9.23.6. , 9.35.4.3. , 9.39.3.3.
- framing, 9.23.6.
- horizontal force factor, 4.1.8.18.
- lateral loads, 9.23.6.1.
- masonry, 9.20.9. , 9.20.11.
- masonry walls to wood-frame construction,
- roofs, floors and intersecting walls, 9.20.11.
- sills, 9.20.11.5.
- small buildings, 9.23.6.3.
- walls, 9.20.11. , 9.23.3.4.
- Ancillary buildings, 7.1.5.4.
- Anhydrous ammonia, storage, 3.3.6.3.
- Annunciators, fire alarm, 3.2.4.8. , 3.2.4.9. , 3.2.4.15. , 3.2.5.14. , 3.2.6.7.
- Antennas and antenna-supporting structures wind loads, 4.1.7.6. , 4.1.7.11.
Apparent sound transmission class (ASTC)
- Applicable law, 1.4.1.3. [A]
Appliances (see also Heating appliances, Heating systems and equipment, Heating, ventilating and air-conditioning systems and equipment), 1.4.1.2. [A]
- access to exit (in), 3.3.1.2.
- air-conditioning, 6.2.1.
- characteristics, 1.2.2.1. [A]
- cooling, 6.2.1. , 6.6.1.1.
- exit (in), 3.4.4.4.
- exterior, 3.6.1.5.
- fuel-fired, 3.6.2.1. , 9.10.10.4.
- heating, 6.2.1.
- installation standards, 6.2.1.5.
- location, 6.4.1.1. , 9.10.10.
- means of egress (in), 3.3.1.2. , 3.6.2.2. , 9.9.5.7.
- outdoor location, 6.2.1.6. , 6.4.1.2.
- protection from freezing, 6.2.1.6.
- roof top, 3.6.2.1.
- solid-fuel burning, 3.6.2.1. , 6.9.4.2.
- ventilating, 6.2.1. , 9.32.3.1.
Application of the Building Code, 1.1.1. [A]
Arches
- Arch roofs, snow and rain load, 4.1.6.10.
- Areas of refuge, 3.3.3.6.
- Areas and spaces, 9.5.
Arena-type buildings, 3.1.2.3. , 3.2.1.1.
- seating, 3.3.2.2.
- Artesian groundwater, 1.4.1.2. [A], 4.2.5.5.
- Asbestos in air distribution systems and equipment, 6.2.1.7.
- Assembly areas, 4.1.3.6 , 4.1.5.3. , 4.1.5.5.
Assembly occupancy (Group A), 3.1.15.2. , 3.2.7.3. , 3.3.2.
- assistive listening devices, 3.8.2.9. , 3.8.3.19.
- application, 1.3.3.2. [A]
- corridors in, 3.1.13.6. , 3.3.1.9. , 3.3.2.6.
- definition, 1.4.1.2. [A]
- doors, 3.3.2.7.
- fire alarm systems, 3.2.4.1. , 3.2.4.18.
- fire protection, 3.2.2.20. - 3.2.2.35.
- fire safety within floor areas, 3.3.1. , 3.3.2.
- location of smoke/fire dampers, 3.1.8.7.
- occupant load, 3.1.17.1.
- room or space classification, 9.10.1.3.
- safety glazing, 3.3.2.17.
- signals to fire department, 3.2.4.7.
- visible alarm signals, 3.2.4.19.
- washrooms, 3.7.2.
- wheelchair spaces, 3.8.2.3.
- Assistive listening systems, 3.8.3.7.
- Attendant booths, 6.3.1.3.
Attic or roof space
- access, 3.6.4.4. , 9.19.2.
- clearances, 9.19.1.3.
- definition, 1.4.1.2. [A]
- exterior wall enclosing, 3.2.3.3.
- fire blocks, 3.1.11.1. , 3.1.11.5. , 9.10.16.1.
- fire protection, 9.10.12.4.
- foamed plastic in, 3.1.4.2. , 9.10.17.10.
- housing and small buildings, 9.19.
- insulation, 9.25.2.4.
- loads, 4.1.5.3. , 9.4.2.4.
- in noncombustible construction, 3.1.5.3.
- service spaces, 3.6.1.1.
- soffits protection, 3.2.3.16.
- venting, 5.3.1.2. , 6.3.1.2. , 9.19.1.
Attics, 3.6.1.1.
- Audible signal device, 3.2.4.17. , 3.2.4.18.
- Auditorium, 3.2.2.21. , 3.2.2.22. , 3.3.2.4.
- Automatic locking devices, 3.3.4.5.
Automatic sprinkler systems
- assembly occupancy (Group A, Division 1), 3.2.2.20.
- assembly occupancy (Group A, Division 2), 3.2.2.23. , 3.2.2.24. , 3.2.2.26. , 3.2.2.27. , 3.2.2.93.
- assembly occupancy (Group A, Division 3), 3.2.2.29. - 3.2.2.33.
- assembly occupancy (Group A, Division 4), 3.2.2.35.
- barrier-free floor areas, 3.3.1.7.
- business and personal services occupancy (Group D), 3.2.2.49. , 3.2.2.51. , 3.2.2.52. , 3.2.2.54. , 3.2.2.56. , 3.2.2.93.
- care or detention occupancy (Group B, Division 1), 3.2.2.36. , 3.2.2.37.
- care or detention occupancy (Group B, Division 2 or Division 3), 3.2.2.38. - 3.2.2.46.
- combustible insulation, 3.1.5.14.
- combustible pipes, 3.1.5.19. , 3.1.9.4. , 3.2.5.13.
- construction, 3.2.5.12.
- contained use areas, 3.3.3.7.
- containment in basements, 3.2.1.5.
- corridors, 3.1.13.6. , 3.3.2.5.
- design, 3.2.5.12.
- egress doorways, 3.3.1.5.
- electrical supervision, 3.2.4.9.
- exceptions for mezzanines, 3.2.8.2.
- exposing building face, 3.2.3.1.
- fire alarm systems, 3.2.4.7. , 3.2.4.8.
- fire department connection, 3.2.5.15.
- firefighting access, 3.2.5.1. , 3.2.5.2.
- fire separations in residential occupancy, 3.3.4.2.
- fire blocking, 3.1.11.5. , 3.1.11.6.
- flame-spread rating, 3.1.13.2.
- garages, 3.3.5.4.
- heavy timber construction, 3.2.2.16.
- high buildings, 3.1.13.7.
- high-hazard industrial occupancy (Group F, Division 1), 3.2.2.72. - 3.2.2.75.
- hold-open devices, 3.1.8.14.
- hose stations, 3.2.5.11.
- impeded egress, 3.2.2.19.
- in lieu of roof rating, 9.10.8.2.
- installation, 3.2.5.12. , 9.10.1.3.
- interconnected floor space, 3.2.8.1.
- libraries, 3.3.2.13.
- limiting distance, 3.2.3.1.
- low-hazard industrial occupancy (Group F, Division 3), 3.2.2.82. , 3.2.2.84. , 3.2.2.86. , 3.2.2.88. , 3.2.2.90. , 3.2.2.93.
- medium-hazard industrial occupancy (Group F, Division 2), 3.2.2.76. , 3.2.2.77. , 3.2.2.79. , 3.2.2.81. , 3.2.2.93.
- mercantile occupancy (Group E), 3.2.2.66. , 3.2.2.67. , 3.2.2.69. , 3.2.2.71. , 3.2.2.93.
- metal roof deck, 3.1.14.2.
- repair garages, 3.3.5.4.
- required, 3.2.2.18.
- residential occupancy (Group C), 3.2.2.47. , 3.2.2.48. , 3.2.2.49. , 3.2.2.51. , 3.2.2.52. , 3.2.2.55. , 3.2.2.93.
- residential occupancy retirement home (Group C), 3.2.2.55A. , 3.2.2.55B. , 3.2.2.55C. , 3.2.2.55D. , 3.2.2.55E.
- separation of public corridors, 3.3.1.4.
- separation of suites, 3.3.1.1. , 9.10.9.15.
- service penetrations, 3.1.9.4. , 9.9.4.2. , 9.10.9.6. , 9.10.9.7. , 9.10.9.8. , 9.10.9.9.
- service spaces, 3.2.5.14.
- shelf and rack storage, 3.16.1.6.
- soffit protection, 3.2.3.16. , 9.10.12.4.
- sprinkler protected glazed wall assembly, 3.1.8.20.
- stages, 3.3.2.14.
- standpipes, 3.2.5.8. ,
- storage garages, 3.2.1.2. , 3.3.5.4.
- storage rooms, 3.3.4.3. , 9.10.10.6.
- storeys below ground, 3.2.2.15.
- system monitoring, 3.3.1.4. , 3.2.4.15.
- testing, 3.2.5.12.
- theatres (see Automatic sprinkler systems, stages)
- travel distance, 3.4.2.4. , 3.4.2.5 , 9.9.8.1. , 9.9.8.2. , 9.9.8.6.
- underground walkways, 3.2.3.20.
- unprotected openings, 3.2.3.1. , 3.2.3.12. , 3.2.3.14. , 3.2.3.15. , 9.10.12.2.
- Awnings, 3.1.16.1.
- Auxiliary water supply, 1.4.1.2. [A]
B
- Back draft prevention, 6.3.2.10. , 6.3.2.10. , 9.32.3.8.
Backfill (see also Fill), 9.12.3.
- Backfill for pipe trench, 7.3.5.1.
Backfilling 4.2.5.8.
Backflow
- caused by back pressure, 7.6.2.3. , 7.6.2.4
- definition, 1.4.1.2. [A]
- from fire protection systems, 7.6.2.4.
- premise isolation, 7.6.2.6.
- preventers, 1.4.1.2. [A], 7.6.2.3. , 7.2.10.10.
- protection of building drains, 7.4.6.4.
- protection of drainage pans on heating/cooling units, 7.4.2.1.
- protection of drinking fountains, 7.4.2.1.
- protection of make-up water, 7.7.2.4.
- protection of potable water system, 7.6.2.6. , 7.6.2.7. , 7.7.2.4.
- protection of rainwater storage tanks, 7.7.2.4.
- solar domestic hot water, 7.6.2.5.
Backflow preventers
Back pressure
Back-siphonage
- definition, 1.4.1.2. [A]
- preventers, 1.4.1.2. [A], 7.2.10.10. , 7.6.2.2.
- prevention, 7.6.2.
Backwater valves,
- Bacteria, minimizing growth, 6.3.1.5. , 6.3.2.15. , 6.3.2.16.
- Balance stops, 9.33.6.9.
Balconies, 3.1.11.5. , 3.2.3.6. , 9.10.16.1.
- access to exit (as), 9.9.9.3.
- barrier-free, 3.8.2.4.
- combustible projections, 3.1.10.7 , 3.2.3.6. , 9.10.14.5. , 9.10.15.5.
- concealed spaces in, 3.1.11.5.
- construction of exterior, 3.2.2.11.
- doors and door hardware, 3.3.1.13.
- earthquake load and effects, 4.1.8.18.
- exception to travel limit, 9.9.9.1.
- exit, 3.3.2.11. , 3.3.4.4. , 3.4.4.1.
- guards around, 3.1.21.1. , 3.3.1.18. , 9.8.8.
- horizontal exits, 3.4.6.10.
- limiting distance, 3.2.3.6.
- loads on floor or roof, 4.1.5.3. , 4.1.5.4. , 9.4.2.1. , 9.4.2.3.
- occupant load, 3.1.17.1.
- residential, 3.3.1.7.
- snow loads, 9.4.2.3.
- sprinkler systems, 3.2.5.12.
- wind loads, 4.1.7.5. , 4.1.7.6.
- Ball tests, 7.3.6.1. , 7.3.6.2. , 7.3.6.7.
Barrier-free, 1.4.1.2. [A]
- accessible change space, 3.8.2.8. , 3.8.3.13.
- adult-size change table, 3.8.3.13.
- balconies, 3.3.1.7.
- bathtubs, 3.8.3.13.
- counters, 3.8.3.14. , 3.8.3.15.
- clear floor area/space, 3.3.3.5. , 3.4.6.10. , 3.8.3.2. , 3.8.3.6. - 3.8.3.8. , 3.8.3.10. - 3.8.3.13. , 3.8.3.16. - 3.8.3.18.
- controls, 3.8.1.5. , 3.8.3.8.
- design standards, 3.8. , 3.8.3.1. , 9.5.2.
- drinking fountains, 3.8.3.16.
- doors and doorways, 3.8.3.3.
- elevators, 3.3.1.7. , 3.5.2.2. , 3.8.1.3. , 3.8.2.1. , 3.8.3.5.
- entrances, 3.8.1.2.
- exterior walks, 3.8.3.2.
- floor areas, 3.8.2.1.
- floor surfaces, 3.8.1.3. , 3.8.3.18.
- lavatories, 3.8.3.11.
- parking areas, 3.8.2.2.
- path of travel, 3.8.1.3. , 9.5.2.2.
- platforms, 3.8.3.17.
- ramps, 3.8.3.4. , 9.8.5.1.
- rooftop amenity spaces, 3.8.2.1.
- service counters, 3.8.3.14.
- showers, 3.8.3.13.
- signs, 3.8.3.1.
- soap and towel dispensers, 3.8.3.11.
- spaces in seating areas, 3.8.2.1.
- tactile attention indicators, 3.8.3.18.
- telephone shelves, 3.8.3.15.
- universal washroom, 3.7.4.2. , 3.8.3.12.
- urinals, 3.8.3.10.
- vestibules, 3.8.3.3.
- wall reinforcement, 3.3.4.9. , 9.5.2.4.
- washrooms, 3.8.2.3. , 3.8.3.1. , 3.8.3.8. , 3.8.3.11. , 3.8.3.12.
- water bottle filling station, 3.8.3.16A.
- water closets, 3.8.3.8. , 3.8.3.9. , 3.8.3.12.
- wheelchairs, 3.8.2.1.
- Barriers, across transparent panels, 3.3.1.20.
- Preventing exit obstruction, 3.4.6.11. , 9.9.11.2.
Basements,
- access, 3.2.5.2. , 9.10.20.2.
- ceiling height, 9.5.3.1.
- crawl spaces considered as, 3.2.2.9. , 9.10.8.9.
- definition, 1.4.1.2. [A]
- exit signs, 3.4.5.3.
- fire containment, 3.2.1.5.
- fire protection, 3.2.2.15. , 9.10.1.3.
- fire-resistance of floor assemblies over, 3.2.1.4. , 9.10.9.4.
- fire separation, 9.10.9.4. , 9.10.9.16.
- heating requirements, 9.33.3.1.
- industrial occupancy (Group F), 3.3.5.3. , 3.3.6.9.
- insulation, 9.25.2.3.
- large or multi-storey, 9.10.1.3.
- lighting, 9.34.2.3. , 9.34.2.4.
- process plants, 3.3.6.9.
- residential occupancy (Group C), 3.2.2.47. - 3.2.2.55. , 3.2.2.93.
- storage garages, 3.1.10.3. , 3.2.1.2. , 9.10.4.3.
- supply outlets, 9.33.6.11.
- Bathroom accessories, 3.8.3.8. - 3.8.3.12.
Bathrooms
- Bathtubs, 3.8.3.13. , 7.2.2. , 7.2.10.7. , 7.4.9.3. , 7.6.3.2. , 9.6.1.4.
- bearing, 9.23.8.1.
- built-up, 9.23.4.2. , 9.23.8.3.
- dimensions, 9.23.4.1.
- glued-laminated, 9.23.4.2.
- lumber grade, 9.3.2.1.
- preservative treatment, 9.23.2.2. , 9.23.2.3.
- ridge, 9.23.14.8.
- size, 9.23.4.1.
- spans, 9.23.4.2.
- spans, maximum, 9.23.4.
- steel, 9.23.4.3. , 9.23.8.2.
- supported on masonry or concrete, 9.10.9.11. , 9.15.5. , 9.20.8.3. , 9.20.8.4. , 9.21.5.3. , 9.23.2.2.
- to support floors, 9.23.8.
- wood, 9.23.4.1. , 9.23.4.4.
- Bearing surface, 1.4.1.2. [A]
- Bedpan washers, 7.6.3.2.
Bedrooms
- Beer cabinets, 7.4.9.3.
- Bell and spigot pipe, 7.3.2.7.
- Bell traps, 7.2.3.1.
- Bidets, 7.4.9.3. , 7.6.3.2.
Bins,
- Bio-contaminants, minimizing growth of, 6.3.1.5. , 6.3.2.15.
Bleachers,
Blocking
- cladding, 9.27.5.2.
- cladding and interior finishing materials, 9.23.10.5.
- doors, 9.7.5.2.
- with handrails, 9.8.7.7.
- joists, 9.23.9.3. , 9.23.9.4. , 9.23.14.9.
- nailing, 9.23.3.4.
- in noncombustible construction, 3.1.5.2.
- rafters and joists, 9.23.14.7.
- roof edges, 9.23.16.6. , 9.23.16.7.
- subflooring, 9.23.15.3.
- walls, 9.23.9.8. , 9.23.10.2
- Boarding, lodging or rooming houses, 1.4.1.2. [A], 9.9.8.2. , 9.10.9.16.
- Boiler rooms, 3.6.2.1. , 9.10.10.
- Boilers definition, 1.4.1.2. [A]
- Bolts, 7.2.10.2. , 7.2.10.3.
Bonding
- intersecting masonry walls, 9.20.11.2.
- masonry, 9.20.9.
- Book shelves, 3.3.2.13.
- Braced wall bands, 9.23.13.4. , 9.23.13.5.
Braced wall panels
- anchorage, 9.23.6.1. , 9.23.13.5.
- fastening, 9.23.3.4. , 9.23.3.5.
- gypsum board, 9.29.5.9.
- lateral loads, 9.23.13.5. , 9.23.13.6.
- plywood, 9.29.6.3.
- and wall supports, 9.23.9.8.
- Bracing wood frame walls, 9.23.10.2. , 9.23.13.4. , 9.23.13.5.
Branches
Branch vents
- Brass floor flanges, 7.2.10.1.
- Brass pipe, 7.2.7.1. , 7.3.4.5.
- Brass pipe flanges and fittings, 7.2.7.2. , 7.2.7.3.
- Brazing alloys, 7.2.9.2.
- Breeching, 1.4.1.2. [A]
- Bridging floor joists, 9.23.9.4.
- Bronze pipe flanges and fittings, 7.2.7.2. , 7.2.7.3.
- Bronze threaded water fitting, 7.2.7.3.
Building area, 1.4.1.2. [A]
- assembly occupancy (Group A, Division 1), 3.2.2.20. - 3.2.2.22.
- assembly occupancy (Group A, Division 2), 3.2.2.23. - 3.2.2.28. , 3.2.2.93.
- assembly occupancy (Group A, Division 3), 3.2.2.29. - 3.2.2.34.
- assembly occupancy (Group A, Division 4), 3.2.2.35.
- business and personal services occupancy (Group D), 3.2.2.56. - 3.2.2.65. , 3.2.2.93.
- care or detention occupancy (Group B, Division 1), 3.2.2.36. , 3.2.2.37.
- care or detention occupancy (Group B, Division 2 or Division 3), 3.2.2.38. - 3.2.2.46.
- determining fire safety requirements, 3.2.2.5.
- high-hazard industrial occupancy (Group F, Division 1), 3.2.2.72. - 3.2.2.75.
- low-hazard industrial occupancy (Group F, Division 3), 3.2.2.82. - 3.2.2.93.
- medium-hazard industrial occupancy (Group F, Division 2), 3.2.2.76. - 3.2.2.81. , 3.2.2.93.
- mercantile occupancy (Group E), 3.2.2.66. - 3.2.2.71. , 3.2.2.93.
- residential occupancy (Group C), 3.2.2.47. - 3.2.2.55. , 3.2.2.93.
Building assemblies
- fire-resistance rating, 3.1.7.5.
Building classification
- Building drains (see drainage systems)
Building height
- assembly occupancy (Group A, Division 1), 3.2.2.20. - 3.2.2.22.
- assembly occupancy (Group A, Division 2), 3.2.2.23. - 3.2.2.28. , 3.2.2.93.
- assembly occupancy (Group A, Division 3), 3.2.2.29. - 3.2.2.34.
- assembly occupancy (Group A, Division 4), 3.2.2.35.
- business and personal services occupancy (Group D), 3.2.2.56. - 3.2.2.65. , 3.2.2.93.
- care, treatment or detention occupancy (Group B Division 1), 3.2.2.36. , 3.2.2.37.
- care, treatment or detention occupancy (Group B Division 2), 3.2.2.38. - 3.2.2.41.
- care, treatment or detention occupancy (Group B Division 3), 3.2.2.42. - 3.2.2.46.
- definition, 1.4.1.2. [A]
- determination, 1.3.3.4. [A], 3.2.1.1. , 9.10.4.
- determination of fire safety requirements, 3.2.2.5.
- exceptions, 3.2.1.1.
- garages as separate buildings, 9.10.4.3.
- high-hazard industrial occupancy (Group F, Division 1), 3.2.2.72. to 3.2.2.75.
- low-hazard industrial occupancy (Group F, Division 3), 3.2.2.82. – 3.2.2.93.
- medium-hazard industrial occupancy (Group F, Division 2), 3.2.2.76. – 3.2.2.81. , 3.2.2.93.
- mercantile occupancy (Group E), 3.2.2.66. – 3.2.2.71. , 3.2.2.93.
- mezzanines excluded, 9.10.4.1.
- mezzanines included, 9.10.4.2.
- residential occupancy (Group C), 3.2.2.47. - 3.2.2.55. , 3.2.2.93.
- rooftop enclosures excluded, 9.10.4.4.
Building size determination
Building sewers
- cleanouts, 7.4.7.1. , 7.4.7.2.
- combined, 7.1.5.1. , 7.4.5.2.
- definition, 1.4.1.2. [A]
- drawings for plumbing permit, 7.2.2.1.
- developed length, 7.4.7.2.
- hydraulic load, 7.4.10.6. , 7.4.10.8. , 7.4.10.9.
- mobile homes, 7.4.6.5.
- sanitary, 1.4.1.2. [A], 7.4.7. , 7.4.10.8.
- sizing, 7.4.7.2. , 7.4.9.4. , 7.4.10.8. , 7.4.10.9.
- slope, 7.4.8.1. , 7.4.10.8. , 7.4.10.9. , 7.4.10.10.
- storm, 1.4.1.2. [A], 7.4.10.9.
- Building size and construction relative to occupancy, 9.10.8.
Building size determination, 1.3.3.4. [A]
Building traps, 7.4.5.
- Built-up roofing, 9.26.11.
Business and personal services occupancy (Group D)
- classification, 3.1.2.1. , 9.10.2.
- definition, 1.4.1.2. [A]
- emergency power for fire alarm systems, 3.2.7.8.
- emergency power for lighting, 3.2.7.4.
- exit stairs, 9.9.4.7.
- exposing building face, 9.10.14.5.
- fire access route design, 3.2.5.6.
- fire alarm systems, 3.2.4.1. , 9.10.18.
- fire protection, 3.2.2.56. - 3.2.2.65.
- fire-resistance rating, 9.10.8.
- fire safety within floor areas, 3.3.1.
- flame-spread rating, 9.10.17.
- occupant load, 3.1.17.1.
- sprinkler systems, 3.2.5.12.
- washrooms, 3.7.4.
- Butt fusion fittings, 7.2.5.4.
- Butt weld pipe fittings, 7.3.2.8.
C
- Cabinetry, around cooktops, 9.10.22.2. , 9.10.22.3.
- Caisson (See Pile)
Calculations and analysis
Camp for housing of workers
Canopies, 3.2.3.6.
Capacity
- Carbon dioxide equivalents, 12.2.2.
Carbon monoxide
- alarms, 9.32.3.9. , 9.32.3.9A. , 9, 32.3.9B. , 9.32.3.9C.
- concentration, 6.3.1.3.
- detectors, 6.3.1.3. , 6.9.3.1.
- garage (in), 3.3.5.4. , 6.3.1.3.
- Care occupancy, small, (as) residential occupancy, 3.1.2.5.
Care, care and treatment or detention occupancy (Group B), 3.2.2.19. , 3.2.5.12. , 3.3.3.1.
- air circulation, 6.3.2.7.
- building classification, 3.1.2.1.
- carbon monoxide alarms, 6.9.3.1.
- definition, 1.4.1.2. [A]
- door hold-open devices, 3.1.8.14.
- doorway width, 3.3.3.4.
- electromagnetic locks, 3.4.6.16.
- emergency lighting, 3.2.7.3.
- emergency power supply, 3.2.7.6.
- evaporative heat rejection systems, 6.3.2.15.
- fire alarm systems, 3.2.4.1. , 3.2.4.18.
- fire protection, 3.2.2.36. - 3.2.2.46.
- fire safety within floor areas, 3.3.1. , 3.3.3.
- occupant load, 3.1.17.1.
- ramp slope maximum, 3.4.6.7.
- as residential occupancy, 3.1.2.5.
- self-closing door hardware, 3.1.8.13.
- sleeping room exits, 3.4.1.6.
- smoke alarms, 3.2.4.20.
- smoke detectors, 3.2.4.11.
- sprinkler systems, 3.2.2.19.
- sleeping areas, 3.7.1.3.
- visual signal, 3.2.4.19.
- Carpets, 3.1.13.1.
Carports (see also Garages, open air), 9.35.
- columns, 9.35.4.2. , 9.35.4.3.
- concrete for floors, 9.3.1.6.
- for dwelling units, 9.35.
- spatial separation from other buildings, 9.10.14.1. , 9.10.14.4.
- walls, 9.35.4.1. , 9.35.4.3.
- Catch basins, 9.14.6.4.
- Cast-iron drainage and vent pipe and fittings, 7.2.6.1. , 7.2.6.3.
- Cast-iron fittings, 7.2.6.1. , 7.2.6.3. , 7.2.6.5.
- Cast-iron fixtures, 7.2.2.2.
- Cast-iron pipes, 7.3.2.1. , 7.3.3.3. , 7.3.3.8. , 7.3.4.5.
- Cast-iron traps, 7.2.3.1. , 7.3.3.8.
- Cast iron water pipe and fittings, 7.2.6.4. , 7.2.6.5. , 7.3.4.5.
Catch basins
- Caulked lead drainage joints, 7.3.2.1.
- ceramic wall tile, 9.29.10.5.
- cladding, 9.27.4. , 9.27.9.4. , 9.27.10.3.
- door frames, 9.20.13.11.
- material properties, 9.27.4.2.
- material standards, 9.27.4.2. , 9.29.10.5.
- in noncombustible construction, 3.1.5.2.
- requirements, 9.27.4. , 9.27.4.1.
- siding, 9.27.4. , 9.27.9.4. , 9.27.10.3.
- sill plates, 9.23.7.2.
- stucco, 9.28.1.5.
- window frames, 9.20.13.11.
- windows, 9.7.6.2.
- Caulking compounds, cold, 7.3.2.7.
- Caulking lead, 7.2.9.2.
Cavity walls,
- corbelling, 9.20.12.2.
- definition, 1.4.1.2. [A]
- flashing, 9.20.13.6.
- framing supported by, 9.20.8.2.
- height and thickness, 9.20.6.2.
- lateral support, 9.20.10.1.
- mortar droppings, 9.20.13.10.
- precipitation protection, 9.27.2.2.
- tying, 9.20.9.4.
Ceiling membranes
- Ceiling panels, factory-assembled, 3.1.5.
Ceilings
- assembly used as plenum, 3.6.4.3.
- in corridors, 3.1.13.6.
- fastened to floor joists, 9.23.9.4.
- finish, 9.29.
- foamed plastics in, 9.10.17.10.
- framing, 9.23.14.
- framing around openings, 9.23.14.2.
- height, 9.5.3.
- joists, 9.23.14.
- thermal insulation, 9.25.1.1
- Cellular core PVC pipe and fittings, 7.2.5.16.
- Cement jointing mortar, 7.2.9.1.
- Cement-mortar pipe lining, 7.2.6.4.
- Cement, standard for, 9.3.1.2.
- Central alarm and control facility, 3.2.4.22. , 3.2.6.4. , 3.2.6.7.
- Ceramic china fixtures, 7.2.2.2.
Ceramic tile, 9.29.10. , 9.30.6.
- as flooring, 9.30.6.
- as interior finish, 9.29.10
- installation, 9.29.10.1. - 9.29.10.5.
- subfloor, 9.23.15.5.
- underlay, 9.23.15.5. , 9.30.2.1. , 9.30.2.2.
- Change of Use, 1.3.3.3A. [A], 3.17. , 9.41. , 10.1.1. , 11.4.2.3. , 1.3.1.4. [C]
- Chases, 9.20.7.
- Check valves, 1.4.1.2. [A], 7.2.11.4. , 7.4.2.1.(1) , 7.4.6.3.(6) , 7.6.1.10. , 7.6.2.4.
- Chemical storage locations, 7.4.3.4.
- Children's custodial homes, 3.1.2.5.
Chimneys,
- access ladders, 6.3.3.4.
- bracing, 9.21.4.5.
- caps, 9.21.4.6.
- cleanouts, 9.21.4.7.
- clearances, 9.21.5. , 9.25.3.3.
- concrete, 6.3.1.2. , 9.21.4.2.
- concrete material for, 9.21.4.2.
- construction, 9.21.4.
- definition, 1.4.1.2. [A]
- design of, 6.3.3.2. , 9.21.
- earthquake loads and effects, 4.1.8.18.
- factory-built, 1.4.1.2. [A], 9.21.1.3.
- fireplace, 9.21.2.4. - 9.21.2.6.
- flashing, 9.21.4.6. , 9.21.4.10. , 9.26.4.3. , 9.26.4.5. 9.26.4.8.
- flues, 9.21.2. , 9.21.4.4. , 9.21.4.9.
- footings, 9.21.4.3.
- fuel-fired appliances, 9.32.3.8.
- incinerators, 9.10.10.5. , 9.21.2.1.
- lateral stability, 9.21.4.5.
- liners (see also Liners, chimney), 1.4.1.2. [A], 9.21.3. , 9.21.4.9.
- masonry, 6.3.3.2. , 9.21.
- metal, 6.3.1.3. , 9.21.1.2.
- penetrating fire separations, 3.1.9.1.
- saddles, 9.26.4.8.
- sealing, 9.21.5.2.
- venting equipment, 6.3.3.1.
- walls, 9.21.1.2.
- wall thickness, 9.21.4.8.
- Chlorinated poly (vinyl chloride) CPVC pipe, fittings and solvents, 7.2.5.8. , 7.2.5.9. , 7.2.5.11. , 7.3.4.5.
Chutes
Circuit vents
Cladding, 3.1.5.5. , 3.1.5.6. , 3.2.3.7. , 5.6. , 9.27.
- attachment, 9.27.5.
- for braced wall panels, 9.23.13.6.
- combustible, 3.1.5.5. , 3.1.5.6. , 9.10.14.5. , 9.10.15.5.
- in combustible construction, 3.1.4.8.
- exposing building face, 3.2.3.7.
- fastening to flat wall insulating concrete form units, 9.27.5.4.
- housing and small buildings, 9.27.
- fastening to steel studs, 9.24.1.4.
- installation, 9.23.16.3. , 9.27.5.
- interior, 3.1.13.1.
- noncombustible, 3.1.4.8. , 3.2.3.7. , 3.2.3.9.
- in noncombustible construction, 3.1.5.5. , 3.1.5.6.
- protection against precipitation, 5.6.
- requirement for, 5.6.1.1. , 9.27.2.1.
- sealed, 5.6.2.1.
- steel studs (on), 9.24.1.5.
- support, 9.20.5. , 9.23.10.5. , 9.24.3.4.
- waterproofing, 9.27.4.
- wind loads, 4.1.7.5. , 4.1.7.6. , 4.1.7.14.
- Cladding, asphalt, 9.27.1.1.
- Cladding, clay tile, 5.10.1.1.
Cladding, concrete
- Cladding, decorative, 3.1.5.24.
- Cladding, exterior insulation finish systems, 5.10.3. , 9.27.14.
- application, 9.27.1.1. , 9.27.14.1.
- material standards, 5.10.3.1. , 9.27.14.2.
- design and installation, 9.27.14.3.
- Cladding, hardboard, 9.27.9.
- Cladding, limestone, 9.20.6.6.
Cladding, insulated vinyl siding and vinyl siding
- housing and small buildings, 9.27.12.
- installation, 9.27.5. , 9.27.12.2.
- material standards, 5.9.1.1. , 9.27.12.1.
Cladding, lumber, 9.27.6.
Cladding, masonry, 9.20.
Cladding, metal, 9.27.11.
- housing and small buildings, 9.27.11.
- installation, 9.27.5.
- material standards, 5.10.1.1. , 9.27.11.1.
Cladding, OSB and waferboard, 9.27.10.
- clearances, 9.27.10.4.
- dimensions, 9.27.10.2.
- installation, 9.27.5. , 9.27.10.3.
- material standards, 5.10.1.1. , 9.27.10.1.
Cladding, plywood, 9.27.8.
Cladding, vinyl, 9.27.12.
- installation, 9.27.5. , 9.27.12.2.
- material standards, 5.10.1.1. , 9.27.12.1.
Cladding, polypropylene
- attachment, 9.27.13.2.
- material standards, 9.27.13.1.
- Cladding, stone, 9.20.6.6.
- Cladding, waferboard (see Cladding, OSB and waferboard)
Cladding, wood shingles and shakes, 9.27.7.
- Classes of fire sprinkler/standpipe systems, 1.4.1.2. [A], 7.6.2.4.
Classification of buildings/building parts
Cleaning
- Cleaning of potable water systems, 7.6.2.8.
Cleanouts, 7.4.7.
- accessibility for cleaning and maintenance, 7.1.3.2.
- definition, 1.4.1.2. [A]
- for drainage systems, 7.4.7.1.
- fittings, 7.2.10.3. , 7.4.7.1.
- for traps, 7.2.3.1.(3) , 7.4.5.2. - 7.4.5.4. , 7.4.7.1.(2) , 7.4.7.4.
- installation of, 7.4.7.
- location of, 7.1.3.2. , 7.4.7.1. , 7.4.7.4.
- manhole as, 7.4.7.1. , 7.4.7.3. , 7.5.7.6.
- rodding of, 7.4.7.2.(4) , 7.4.7.4.(1)
- size and spacing of, 7.4.7.2.
- Clear water waste, 1.4.1.2. [A], 7.4.2.1.(1) , 7.4.4.2. , 7.4.5.1.
Clearances
- above ground, 9.3.2.9. , 9.15.4.6. , 9.23.2.2. , 9.23.2.3.
- above ground electrical conductors, 3.1.19.
- attic or roof spaces, 9.19.1.3.
- chimneys, 9.21.5. , 9.25.3.3.
- cladding above ground, 9.27.2.4.
- cladding to roof, 9.27.2.4.
- combustible material, 6.7.1.2. , 9.22.9.3. , 9.22.9.4.
- crawl spaces, 9.18.4.1.
- door and window frames, 9.27.9.5.
- ducts, 6.2.4.10. , 9.22.9.4.
- electric and gas-fired ranges, 9.10.22.
- fireplaces, 9.22.10.
- furnace plenums, 6.3.2.6.
- gas vents, 9.25.3.3.
- hardboard siding, 9.27.10.5. , 9.27.11.4.
- heating and air-conditioning equipment, 6.4.1.2.
- pipes, 6.7.1.2.
- siding above ground, 9.27.2.4.
- siding to roof, 9.27.2.4.
- smoke chambers, 9.22.9.3.
- solid-fuel fired appliances, 6.2.1.5.
- stucco, 9.28.1.4.
- unit heaters, 6.4.2.1.
- Climatic data, SB-1
Closure, 1.4.1.2. [A], 3.1.8.1. , 3.1.8.12. , 3.2.3.1. , 3.2.3.13. , 9.10.9.3 , 9.10.13.1.
- chutes, 3.6.3.3.
- door latches, 3.1.8.14.
- exterior wall openings, 3.2.3.5. , 9.10.14.4. , 9.10.15.4.
- fire dampers, 3.1.8.7. , 9.10.13.13.
- fire-protection rating, 3.1.8.4. , 9.10.13.1.
- fire separations (in), 3.2.8.2. , 3.3.3.5. , 9.10.9.3. , 9.10.13. , 9.10.13.8.
- glass blocks, 3.1.8.16. , 3.2.3.5. , 9.10.13.7.
- hold-open devices, 3.1.8.14. , 9.10.13.11.
- installation, 3.1.8.5. , 9.10.13.1.
- maximum openings, 3.1.8.6.
- protection of exit facilities, 3.2.3.13.
- self-closing devices, 3.1.8.13.
- smoke dampers, 3.1.8.7. , 3.1.8.9. , 3.1.8.11.
- temperature limit, 3.1.8.17.
- twenty-minute, 3.1.8.12.
- unprotected openings, 3.2.3.1
- wired glass, 3.1.8.16. , 3.2.3.5. , 9.10.13.5.
- Clothes washers, 7.4.2.1. , 7.4.5.1. , 7.4.9.3. , 7.6.3.2. , 7.7.2.2.
- Cold caulked joints, 7.3.2.7.
Cold weather requirements concrete, 9.3.1.9.
- excavations, 9.12.1.3.
- gypsum board, 9.29.5.10.
- heating, ventilating and air-conditioning systems equipment, 6.2.1.6.
- masonry, 9.20.14.
- stucco, 9.28.6.1.
- Collar ties, 9.23.14.7.
Columns, 9.17.
- anchorage, 9.23.6.2. , 9.35.4.3.
- carports, 9.35.3.4. , 9.35.4.2.
- concrete, 9.17.6.
- fire-resistance rating, 9.10.8.3.
- garages, 9.35.4.2. , 9.35.3.4.
- heavy timber construction, 3.1.4.7.
- housing and small buildings, 9.17.
- lateral support, 9.17.2.2.
- masonry, 9.17.5.
- steel, 9.17.3.
- supported on masonry or concrete, 9.20.8.4.
- wood, 9.17.4.
- Cold-caulked joints, 7.3.2.7.
Combined building drains
- Combined sewers connections, 7.1.2.1. , 7.1.2.2. , 7.4.5.2.
- Combined temperature and pressure relief valves, 7.2.10.11. , 7.6.1.12.(4)
Combustible
- Combustible cladding, 3.1.5.5. , 3.1.5.6. , 3.2.3.7. , 9.10.14.5. , 9.10.15.5.
Combustible construction, 1.4.1.2. [A]
- fire-retardant treated wood, 3.1.4.5.
- foamed plastics, 3.1.4.2. , 9.10.17.10.
- heavy timber, 3.1.4.6.
- materials in, 3.1.4.
- projections, 9.10.12.4. , 9.10.14.5. , 9.10.15.5.
- support, 3.1.8.2. , 9.10.9.10.
- wires and cables, 3.1.4.3.
- Combustible content, 3.1.5.
- Combustible dusts and fire hose nozzles, 3.2.5.11.
- Combustible fibres, 3.1.2.6.
Combustible liquids
Combustible materials
Combustible piping
- Combustible projections, 3.1.10.7. , 3.2.3.6. , 3.2.3.16. , 9.10.12.4. , 9.10.14.5. , 9.10.15.5.
- Combustible refuse, 3.6.2.5.
- Combustion venting, 9.32.3.11.
- Commercial cooking equipment, 3.3.1.2. , 6.3.1.6. , 9.10.1.4.
- Commissioning of life safety systems, 3.2.9.1. , 9.10.18.10.
- Compatibility, 5.1.4.2. , 9.27.5.5.
- Compensating construction, 11.4.3.
Compliance
- Compliance alternatives, 1.4.1.2. [A], 11.5.1.
- Compounds, caulking and sealing, 7.2.9. , 7.3.2.7.
- Compressed gas, 3.3.6.3.
Concealed spaces, 3.1.11.1. , 3.1.11.3. - 3.1.11.5. , 3.1.11.7. , 9.10.16.2. , 9.10.17.10.
- fire separations, 3.1.8.3. , 3.6.4.2. , 9.10.9.12.
- fire blocking, 3.1.11. , 9.10.16.
- horizontal, 3.1.8.3. , 9.10.9.12.
- insulation, 3.1.11.2. , 9.10.16.3.
Concrete
- admixtures, 9.3.1.8
- aggregate, 9.3.1.4.
- cantilevered steps, 9.8.10.
- cellular, 9.20.2.4.
- cold weather requirements, 9.3.1.9.
- columns, 9.17.6.
- compressive strength, 9.3.1.6.
- dampproofing, 9.13.2.3. , 9.13.2.4. , 9.13.2.5
- design, 4.2.3.5. , 4.2.3.6. , 9.3.1. , 9.4.1.1.
- design basis, 4.3.3.1.
- flues, 9.21.
- foundations, 4.2.3.5. , 4.2.3.6. , 9.15.
- insulating forms, 9.3.1.1. , 9.13.2.3. , 9.13.3.3. , 9.15.1.1. , 9.15.3.3. , 9.15.3.5. , 9.15.4.1. - 9.15.4.5. , 9.20.1.1. , 9.20.17.
- joints, 9.15.4.9.
- mixes, 9.3.1.7.
- pipe and fittings, 7.2.5.3.
- plain, reinforced and prestressed, 4.3.3. , 9.3.1. , 9.40.
- roof tiles, 9.26.2.1. , 9.26.17.
- slabs (see also Floors-on-ground), 9.16.4.
- stairs, 9.8.9.2. , 9.8.10.
- standard for, 9.3.1.1. , 9.3.1.3.
- strength, compressive, 9.3.1.6.
- structural design basis, 4.3.3.1.
- sulphate-resistant, 9.3.1.3.
- surface finish, 9.16.4.1.
- as thermal barrier, 3.1.5.14. , 3.1.5.15
- topping, 9.16.4.2. , 9.23.4.4.
- Concrete block, 9.15.2.2. , 9.17.5.1. , 9.20.2.6.
- Concrete pipe and fittings, 7.2.5.2.
Condensation
Condensation control
- Conditioned space, 1.4.1.2. [A]
- Conflicting requirements, 1.5.1.2. [A]
- Connected buildings, 3.2.6.3.
Connections
- direct, 1.4.1.2. [A], 7.4.2.1.(1) , 7.4.2.3.
- dissimilar material, 7.3.3.6.
- drainage systems, 7.1.2.1. , 7.1.2.2. , 7.4.2. , 7.4.3.4. , 7.4.5.3.
- of drains, 7.4.2.1. , 7.4.2.3. , 7.4.3.4. , 7.4.3.6.
- fire department, 3.2.5.16.
- fixture, 7.4.2.1 - 7.4.2.3. , 7.4.3.4. , 7.4.4.4. , 7.5.4.2. , 7.5.5.5. , 7.5.6.4.
- increasers, 7.3.3.5.
- indirect, 7.4.2.1.(1) , 7.3.3.11. , 7.4.2.1. , 7.4.3.2. , 7.4.4.4. , 7.4.5.1.
- lead bend, 7.4.2.1.
- nominally horizontal offset, 7.4.2.1.
- nominally horizontal sanitary drainage pipe, 7.4.2.1.
- of outlet fixtures, 7.3.3.8.
- of overflows from rainwater tanks, 7.4.2.2. , 7.7.2.4.
- reducers, 7.3.3.5.
- of roof drains, 7.3.3.7.
- running thread and packing nut, 7.3.3.4.
- of separate services, 7.1.2.4.
- of storm drainage systems, 7.1.2.2. , 7.4.5.2.
- of subsoil drainage, 7.4.5.3.
- service, 7.1.5.
- to a vent stack, 7.5.2.1.(1)
- unions and slip joints, 7.3.3.4.
- of vent pipes and circuit venting, 7.4.2.1. , 7.5.3. , 7.5.5.5. , 7.5.6.2. , 7.5.6.4.
- of water systems, 7.1.2.3. , 7.6.2.1. , 7.6.2.3. , 7.6.2.4. , 7.7.1.1.
- trap, 7.2.3.1.(3)
- Construction camps, 9.10.21.
- Construction index, 1.4.1.2. [A], 11.2.1.1. , Table 11.2.1.1.-A .
- Construction types, 9.10.6.
- Contained use areas, 1.4.1.2. [A], 3.2.2.19. , 3.2.4.1. , 3.2.4.9. , 3.2.4.12. , 3.3.1.12. , 3.3.3.7. , 3.4.6.16.
Contaminated air
Contamination protection
- Continental seating, 3.3.2.4.
- Continuous vents, 1.4.1.2. [A], 7.5.1.1. , 7.5.2.1. , 7.5.8.3.
- Control joints, 9.15.4.9.
Controls
- Convectors, 6.2.8.
- Cooking equipment, commercial ventilation of, 6.3.1.6.
Cooktop,
- clearances, 9.10.22.1. , 9.10.22.2. , 9.10.22.3.
- definition, 1.4.1.2. [A]
- fans, 9.32.3.11.
- hoods, 9.10.22.2.
- installation, 9.33.5.3.
- protection around, 9.10.22.3.
- Coolers, walk-in, 3.1.4.2. , 3.1.5.7. , 9.10.17.10
- Cooling of Hot Water or Sewage, 7.4.4.2.
Cooling systems and equipment
- Cooling of hot liquid waste, 7.4.4.2.
- Copper joints, 7.3.3.12.
- Copper pipe, 7.2.7.1. , 7.3.4.3. , 7.3.4.5.
- Copper tube, 7.2.7.4. , 7.3.3.11. , 7.3.4.5.
- Corbelling, 9.15.4.8. , 9.20.12.
- Cornices, 3.1.11.5. , 9.10.16.1. , 9.20.11.5.
Corridors (see also Public corridors), 3.1.8.19. , 3.1.13.6.
- access to exit, 3.3.2.6. , 9.9.7. , 9.9.9.3.
- care or detention occupancy, 3.3.3.3.
- dead end, 3.3.1.9. , 3.3.3.3. , 9.9.7.3.
- dimensions, 3.3.1.9. , 9.9.3.3. , 9.9.5.2.
- doors opening onto, 3.3.1.11. , 9.9.6.2. , 9.10.13.12.
- emergency lighting, 3.2.7.3. , 9.9.12.3.
- fire separations, 9.10.9.17.
- flame-spread rating, 3.1.13.6. , 3.1.13.7. , 9.10.17.
- floor loads, 4.1.5.3. , 4.1.5.4.
- illumination, 3.2.7.1. , 3.2.7.3. , 9.9.12.2.
- obstructions, 3.3.1.9. , 9.9.5.2. , 9.9.5.3.
- occupancy, 3.3.1.9. , 9.9.5.2.
- paired doors, 3.3.1.11. , 3.3.3.3.
- transparent doors, 3.3.1.20.
- transparent panels, 3.3.1.18.
- width, 3.3.1.9. , 9.9.3. , 9.9.5.2.
- windows, 3.3.1.20.
Corrosion protection (see also Corrosion resistance)
Corrosion resistance (see also Corrosion protection)
- ducts, 6.3.2.10. , 6.3.2.3. , 6.3.2.6A. , 9.32.3.11. , 9.33.6.2.
- elements in environmental separators, 5.1.4.2.
- fasteners for cladding, 9.27.5.5.
- masonry connectors, 9.20.16.1.
- plumbing, 9.31.2.2.
- screens, grills, 6.3.2.9. , 9.32.3.13.
- service water heaters, 9.31.6.3.
- siding fasteners, 9.27.5.5.
- Corrosion-resistant materials, 7.2.2.1. , 7.2.8. , 7.2.10.2. , 7.4.7.3.
Counters
Couplings corrugated steel, 7.2.6.8.
- mechanical, 7.2.10.4.
- Corrugated steel pipe and coupling, 7.2.6.8.
- Couplings, mechanical pipe, 7.2.10.4.
Coverings
- ducts, 3.6.5.4. , 9.10.17.12. , 9.33.6.4.
- pipes, 6.5.1.1.
- roof, 3.1.15.1.
- Crack control joints, 9.15.4.9
- CPVC, (see Chlorinated poly pipe)
- Cranes, loads due to, 4.1.2.1. , 4.1.5.11.
Crawl spaces, 3.1.11.1. , 3.1.11.6. , 9.18.
- access, 3.6.4.6. , 9.18.2.1. , 9.18.4.1.
- air barrier systems, 9.18.1.3.
- clearance, 9.18.4.1.
- drainage, 9.18.5.
- fire resistance of floors over, 9.10.8.1. , 9.10.9.4.
- fire block (in), 9.10.16.1.
- flame-spread rating, 9.18.7.1.
- foamed plastics, 9.10.17.10.
- ground cover, 9.18.6.
- heated, 9.18.1.3.
- heating, 9.33.3.1.
- insulation, 9.18.1.3. , 9.25.2.3. .
- regulated as basements, 3.2.2.9. , 9.10.8.9.
- supply outlets, 9.33.6.11
- used for any occupancy, 9.10.8.9.
- vapour barrier, 9.18.1.3.
- ventilation, 6.3.1.2. , 9.18.3.
- warm air plenums (as), 9.18.7.1.
- Critical level, 1.4.1.2. [A], 7.6.2.10.
- Cross fittings, 7.2.4.1.
Crosslinked polyethylene/aluminum/crosslinked
- Crosslinked polyethylene pipe and fittings, 7.2.5.6. ,
- Curbs, repair and storage garages, 3.3.5.4. , 9.8.8.4.
- Curtain walls (see Fenestration)
- Curved roofs, snow and rain loads, 4.1.6.10.
- Cutting operations room, 3.3.1.26.
- Cuspidors, 7.4.9.3. , 7.6.3.2.
D
Dampers, (also see fire dampers), 3.1.8.7.
Dampproofing
- application standards, 5.8.2.3., 9.13.2.3.
- crawl spaces, 9.18.6.
- floors, 9.23.2.3.
- floors-on-ground, 9.13.2.7.
- foundations, 9.13.2.
- installation, 5.8.2.3., 9.13.2., 9.23.2.3.
- interior, 9.13.2.6., 9.20.13.9., 9.23.2.3.
- material standards, 5.8.2.2., 9.13.2.2.
- preparation of surface, 9.13.2.3.
- protection from groundwater, 5.7.3.4.
- protection of interior finishes, 9.13.2.5., 9.20.13.9., 9.23.2.3.
- requirement for, 5.8.2.1., 9.13.1.1.
- walls, 9.13.2.1., 9.13.2., 9.20.13.9., 9.23.2.3.
Dance halls
Dangerous goods
- Dead-end corridors, 3.1.8.17., 3.3.1.9., 3.3.3.3., 3.3.4.4., 9.9.7.3.
- Dead end corridors, 3.3.1.9., 3.3.3.3., 3.10.2.4., 9.9.7.3.
- Dead ends in piping, 7.4.6.1.
- Dead load (see also Loads, dead), 1.4.1.2. [A], 4.1.4.
- Decay, protection against (see also Deterioration), 5.1.4.2., 9.3.2.9., 9.23.2.2., 9.23.2.3.
- Decking for wood shingled roofs, 9.26.9.1.
Decks
Deep foundations,
- load testing, 4.2.7.2.
- location and alignment, 4.2.7.3. , 4.2.7.4.
- Definitions of words and phrases, 1.4.1. [A], 3.13.1.2. , 4.1.3.1. , 7.1.3. , 11.1.1.2.
Deflections
- Deformation resistance, 9.12.2.2. , 9.15.1.3.
- Demolition review, 1.2.2.3. [C]
- Dental units, 7.4.9.3. , 7.6.3.2.
Depressurization
Design
Designer
Design temperatures
- Designated structures, 1.3.3.5. [A]
Detectors
- carbon monoxide, 6.9.3.1. , 9.32.3.9. , 9.32.3.9A. , 9.32.3.9B. , 9.32.3.9C.
- fire, 3.2.4.10.
- heat, 3.2.4.11. , 9.10.18.4.
- smoke, 3.2.4.11. , 3.2.4.12. , 6.9.2.2. , 9.10.18.3. - 9.10.18.5. , 9.10.21.7.
- sprinklers installed in lieu of, 9.10.18.4.
Deterioration (see also Decay)
Developed length
- definition, 1.4.1.2. [A]
- of branch vents, 7.5.8.3.
- of building sewers, 7.4.7.2.
- of circuit vents, 7.5.8.3.
- of continuous vents, 7.5.8.3.
- of fixture outlet pipes, 7.4.8.2.
- of potable water distribution systems, 7.6.1.1.
- of stack vents, 7.5.8.4.
- of trap arm for vent pipes, 7.5.6.3.
- of vent headers, 7.5.8.3.
- Diaphragms, earthquake design, 4.1.8.1. , 4.1.8.11. , 4.1.8.15. , 4.1.8.18.
Differential movement
- Diffusers (see also Air outlets), 6.3.2.9. , 9.33.6.11.
- Dilution tanks, 7.4.4.4. , 7.5.5.3. , 7.5.7.7. , 7.5.8.5.
- Dining areas, loads, 4.1.5.6.
- Dispensing rooms, flammable and combustible liquids, 3.3.6.4
- Direct flush valves, 7.2.10.8.
Directly connected
- Dishwashers, 7.4.5.1. , 7.4.9.3. , 7.6.3.2.
- Dishwashing sinks, overflows, 7.2.2.4.
- Dissimilar materials, joints and connections for, 7.3.3.6.
- Distilled beverage alcohol, 1.4.1.2. [A], 3.3.6.4.
- Distilleries, 1.4.1.2. [A], 3.2.5.11.
- Distribution panel, emergency lighting, 3.2.7.10.
- Domes, snow and rain loads, 4.1.6.10.
Door assemblies
- Documents, referenced, 1.5. [A]
Door frames
- caulking, 9.20.13.11.
- sealant, 9.27.4.1.
- steel, 9.10.13.6.
- thermal breaks, 9.7.3.3.
- wood, 9.10.13.3.
- Door stops, 3.1.8.5. , 9.10.13.16.
Doors, (See also Closures; Doorways)
- action of, 9.9.6.4.
- barrier-free path of travel, 3.8.3.3.
- bathrooms, 3.7.4.15. , 9.5.3F.2. , 9.5.5.2. , 9.5.5.3.
- between a dwelling unit and a garage, 9.10.13.15.
- corridors (in), 3.3.1.11. , 3.3.1.13. , 3.3.3.3. , 9.9.7.3. , 9.10.13.
- dimensions, 3.3.1.13. , 3.3.3.4. , 9.9.6.
- direction of swing, 3.3.1.11. , 3.3.3.3. , 3.4.6.10. , 3.4.6.12. , 3.6.2.6. , 9.9.6.5. , 9.10.13.12.
- dwelling units, 3.1.13.2. , 9.7.2.1. , 9.5.5. , 9.9.6.5. , 9.9.6.8. , 9.9.9.
- emergency crossover access to floor areas, 3.4.6.18.
- for exits, 3.1.8.16. , 3.4.5.1. , 3.4.6.11. , 3.4.6.12. , 3.4.6.16. , 9.9.6.
- egress from suites, 9.9.6. , 9.9.7.3. , 9.9.8. , 9.9.9.
- electrical vault, 3.6.2.7.
- exits, 3.1.8.14. , 3.1.8.16. - 3.1.8.19. , 3.4.5.1. , 3.4.6.10. , 3.4.6.11. , 3.4.6.15. , 9.9.4.3. - 9.9.4.6.
- exterior, 5.3.1.2. , 9.7.3. , 9.7.4.
- fire separations, 3.1.8.12. - 3.1.8.15. , 3.1.8.17. , 3.3.3.5. , 9.10.13.
- flame-spread rating, 3.1.13.2. , 3.1.13.7. , 9.10.17.1.
- glass, 3.1.8.18. , 3.3.1.20. , 9.6.1.3. , 9.9.4.3.
- hardware, 3.1.8.13. - 3.1.8.15. , 3.3.1.20. , 3.3.3.5. , 3.4.6.16. , 3.7.5.2. , 9.9.6.7. , 9.9.6.8.
- height and width, 3.3.3.4. , 3.4.3.4. , 9.5.5. , 9.9.6.
- hold-open devices, 3.1.8.14. , 9.10.13.11.
- housing and small buildings, 9.7.
- incinerator rooms, 3.6.2.6.
- installation, 9.7.6.
- landings (at), 3.4.6.3. , 9.8.6.3.
- latches, 3.1.8.15. , 9.9.6.7.
- locking devices, 3.4.6.16. , 3.3.1.13.
- manufactured and pre-assembled, 9.7.4.
- means of egress (in), 3.3.1.13. , 3.4.6.10. - 3.4.6.16. , 9.9.6. , 9.9.7. , 9.10.13.
- in means of egress from dwelling units, 9.9.9.
- in means of egress from suites, 9.9.6. , 9.9.7.4. , 9.9.7.6. , 9.9.8.
- near steps or stairs, 3.4.6.11. , 9.8.6.2. , 9.9.6.6.
- opening onto landings, 9.8.6.3.
- performance expectations, 9.7.3.
- power operators, 3.8.3.3
- obstructions, 3.4.3.4. , 9.9.6.1. , 9.9.6.2.
- protection, 9.9.8.1.
- release hardware, 3.3.1.13. , 3.3.2.7. , 3.4.6.16.
- resistance to forced entry, 9.7.5.2.
- revolving, 3.4.6.15. , 9.9.6.4.
- self-closing devices, 3.1.8.13. , 9.10.13.10. , 9.10.13.15.
- service rooms, 3.6.2.6. , 9.10.13.12.
- signs, 3.4.5.1.
- sill height, 9.9.9.1.
- site-built, 9.7.5.
- sliding, 3.3.1.12. , 3.4.6.14. , 9.7.3.1.
- in smoke-tight barriers, 9.10.9.3.
- of solid core wood, 9.10.13.
- standards for, 5.10.1.1. , 9.6.1.4. , 9.7.4. - 9.7.6. , 9.10.13.2.
- steps or stairs (near), 3.4.6.11. , 9.9.6.6.
- storage garages, 9.9.6.7.
- storm, 9.7.3.1. , 9.7.3.3.
- swing, 3.3.1.11. , 3.4.6.10. , 3.4.6.12. , 3.6.2.6.
- temperature limit, 3.1.8.17.
- thermal breaks, 5.3.1.2. , 9.7.
- thresholds, 3.3.1.13. , 3.4.6.1. , 3.8.3.6. , 3.8.3.17.
- twenty-minute, 3.1.8.12.
- water closet rooms, 9.5.5.2. , 9.5.5.3.
- water closet stalls, 3.8.3.8.
- Door stops, 9.10.13.16.
Doorways
- access to exit, 3.3.1.17. , 9.9.6.
- barrier-free path of travel, 3.8.3.3.
- bathrooms, 9.5.3F.2. , 9.5.5.2. , 9.5.5.3.
- dimensions, 3.3.3.4. , 3.4.3.2. , 9.5.5. , 9.7.2.2. , 9.9.6.2. , 9.9.6.3.
- dwelling unit and garage (between), 9.10.13.15.
- dwelling units, 9.5.5.1.
- egress from suites, 3.3.1.3. , 3.3.1.5. , 9.9.7.2. , 9.9.7.4. , 9.9.7.5. , 9.9.8. , 9.9.9.
- headroom clearance, 3.4.3.5. , 9.9.6.2.
- landings (at), 9.8.6.2. , 9.8.6.3.
- means of egress (in), 3.3.1.5.
- means of egress from dwelling units, 9.9.9.
- means of egress from suites, 3.3.1.3. , 3.3.1.5. , 9.9.7.2. , 9.9.7.4. , 9.9.7.6. , 9.9.8.
- near stairs, 3.4.6.11. , 9.9.6.6.
- obstructions, 9.9.6.1. , 9.9.6.3.
- ramp landings (at), 9.8.6.3.
- secondary suites, 9.5.5.1.
- service rooms, 9.9.5.8.
- water-closet rooms, 9.5.3F.1. , 9.5.5.2. , 9.5.5.3.
- width, 3.3.3.4. , 3.4.3.2. , 9.5.5. , 9.9.6.3.
- Downspouts, 5.6.2.2. , 9.26.18.2.
- Draft stop, 3.16.1.6.
- Drain, waste and vent piping (see also Plumbing), 3.1.9.4. , 9.10.9.7.
- Drains, (see Building drains, Fixture drains, Roof drains)
Drainage
- above ground masonry walls, 9.20.13.10.
- building envelopes, 5.6.2.1. , 5.6.2.2.
- cladding, 9.27.3.1.
- crawl spaces, 9.18.5.
- disposal, 5.6.2.2. , 9.14.5.
- evacuation site, 9.14.4.3
- floors, 5.8.1. , 9.16.3.3.
- floors-on-ground, 9.16.3.
- footings, 9.14.
- foundations, 5.8.1. , 9.14.
- garage, 9.35.3.3.
- granular layers, 9.12.3.1. , 9.14.2.1. , 9.14.4.
- granular material, 9.14.4.1.
- housing and small buildings, 9.14.
- installation of granular layer, 9.14.4.2. , 9.14.4.4.
- installation of tiles and pipes, 9.14.3.3.
- pipes, 9.14.
- roofs, 5.6.2.2. , 7.4.10.4. , 9.26.1.1. , 9.26.18.
- soil, 9.12.2.2.
- surface water, 5.7. , 9.12.3.2. , 9.14.6.
- tile, 9.14.
- underground ducts (of), 6.3.2.12.
- Drainage equipment, 7.4.6.3.
Drainage fittings
- Drainage joint, caulked lead, 7.3.2.1.
- Drainage pans, 7.4.2.1. , 7.6.1.7.
- Drainage of water piping, 7.6.1.2.
Drainage piping,
Drainage systems,
- arrangement of piping, 7.4.6.
- cleanouts, 7.4.7.
- connections to, 7.4.2. , 7.4.3.4
- definition, 1.4.1.2. [A]
- hydraulic loads, 7.4.10.
- location of fixtures, 7.4.3.
- minimum slope and length of pipes, 7.4.8.
- sanitary, 7.4.4.1. , 7.4.7.1.(1)
- separation, 7.3.5.7.
- size of pipes, 7.4.9.
- storm, 7.4.2.1.(1) , 7.4.5.2. , 7.4.7.1.(1)
- testing of, 7.3.6.
- traps, 7.4.5.
- treatment of sewage and wastes, 7.4.4. , 8.1.3.1.(3)
- Drainage systems, sanitary (see also Plumbing), 3.7.4.1. , 9.31.
Drains
- Drilled and tapped joints, 7.3.3.1.
- Drinking fountain bubblers, 7.2.10.9.
- Drinking fountains, 3.7.4.17. , 3.8.3.16. , 7.2.10.9.
- Drum traps, 7.2.3.1
- Dry standpipes, 3.2.9.2.
- Dry wells, 9.14.5.3.
- Dual vents, 1.4.1.2. [A], 7.5.1.1. , 7.5.8.2.(2) , 7.5.9.1.
- Duct-type smoke detectors, 3.2.4.12. , 9.10.18.5.
- Ductile iron pipe, 7.2.6.4.
Ducts,
- access, 6.8.1.2. , 9.33.4.4.
- access openings, 6.3.2.4.
- adhesives, 3.6.5.4.
- air filters in, 6.8.1.3.
- aluminum, 9.33.6.5.
- branch, 3.1.8.8. , 3.1.8.9. , 9.10.13.13. , 9.32.3.5. , 9.33.6.7. , 9.33.3.9.
- ceiling spaces (in), 3.1.9.5.
- cleaning, 6.2.1.6. , 9.32.3.2. , 9.33.4.4.
- clearances, 6.3.2.6. , 9.5.3.1. , 9.22.9.4.
- combustible, 3.1.5.18. , in or beneath concrete slabs, 9.33.6.7.
- connecting fire compartments, 3.1.8.7. , 9.10.13.13.
- connections, 6.3.2.4. , 9.33.6.6
- connectors, 3.6.5.1. , 6.3.2.3. , 6.3.2.18. , 9.33.6.2.
- construction, 6.3.2.6A. , 9.33.6.6
- commercial cooking equipment, 6.3.1.6.
- coverings, 3.6.5.4. , 9.10.17.12. , 9.33.6.4.
- crawl space, 9.18.1.3.
- design, 6.2.1.1. , 6.2.1.1A. , 6.3.2.1. , 9.33.6.1
- dimensions, 9.32.3.11.
- discharge, 9.32.3.10.
- drainage, 6.3.2.12.
- drain pans, 6.3.2.2.
- exhaust, 3.1.8.8. , 3.1.8.9. , 6.3.2.10. , 9.10.9.18. , 9.32.3.4. , 9.32.3.5. , 9.32.3.10. , 9.33.6.14A.
- exits (in), 3.4.4.4. , 6.9.2.4. , 9.9.4.2.
- fire dampers (in), 3.1.8.7. , 6.9.2.1. , 9.10.13.13.
- fire rated assemblies (in), 3.1.9.5. , 9.10.5.1. , 9.10.9.6.
- fire stops, 3.6.5.4. , 6.3.2.6A. , 9.33.6.6.
- fittings, 6.3.2.3. , 9.32.3.11. , 9.33.6.2. , 9.33.6.5.
- horizontal service space access (in), 3.6.4.5.
- installation, 6.3.2.6A. , 9.33.6.6. , 9.33.6.7.
- insulation, 3.1.5.15. , 3.6.5.4. , 6.3.2.5. , 9.32.3.11. , 9.33.6.7.
- interconnection, 6.3.2.7.
- joints, 6.2.3.3. , 9.33.6.3. , 9.33.6.6. , 9.33.6.7.
- leakage, 9.32.3.11.
- linings, 3.1.5.18. , 3.6.5.4. , 6.3.2.5. , 9.10.17.12. , 9.33.6.4.
- materials, 6.3.2.3. , 9.32.3.11.
- metal, 6.3.2.3.
- noncombustible, 3.1.8.8. , 3.1.8.9. , 9.33.6.2. , 9.33.6.6. , 9.33.6.13.
- noncombustible construction, 3.1.5.18.
- penetrating fire separations, 3.1.8.7. , 3.1.9.1. , 3.1.9.2. , 9.10.9.6.
- penetrating fire stops, 3.1.11.7. , 9.10.16.4.
- return, 9.33.6.6. , 9.33.6.12. , 9.33.6.13.
- sealing, 6.3.2.19. , 9.33.6.3. , 9.33.6.7.
- size, 6.2.1.1. , 9.32.3.11.
- slabs (in or beneath), 9.33.6.7.
- smoke detectors in, 6.9.2.2.
- supply, 6.3.2.9. , 9.32.3.4. , 9.32.3.11. , 9.33.6.6 , 9.33.6.9. , 9.33.6.11.
- systems, 6.3.2. , 9.33.6.
- trunk, 6.3.2.6A. , 9.32.3.5. , 9.32.3.11. , 9.33.6.7.
- underground, 6.3.2.12. , 9.33.6.6.
- ventilation, 6.3.2. , 9.32.3.4. – 9.32.3.7. , 9.32.3.11.
- Duct-type smoke detectors, 3.2.4.12.
- Dumbwaiters, 3.5.1.1. , 3.5.3.2.
- Dusts, hazardous, 3.3.1.21. , 3.3.5.3. , 6.9.1.2.
Dwelling units,
- alarm audibility, 3.2.4.18.
- combustible projections, 3.2.3.6. , 9.10.14.5. , 9.10.15.5.
- definition, 1.4.1.2. [A]
- doors in means of egress, 9.9.6.
- door swing, 3.4.6.12.
- doorways, 9.5.5. , 9.9.6.2. , 9.9.6.3.
- egress, 3.3.4.4. , 9.9.9.
- electrical outlets, 9.34.2.2.
- exception for combustible projections, 3.2.3.6. , 9.10.14.5. , 9.10.15.5.
- fire alarms, 3.2.4.1. , 9.10.18.2.
- fire alarm systems, 3.2.4.1.
- fire detectors, 3.2.4.10.
- fire protection, 3.2.2.47. – 3.2.2.55. , 9.10.8.1.
- fire-protection closures, 3.1.8.5.
- fire-resistance rating, 9.10.8.10.
- fire separations, 3.3.4.2. , 9.9.4. , 9.10.9.4. , 9.10.9.13. , 9.10.9.14. , 9.10.9.16.
- firewalls, 9.10.11.2.
- floors-on-ground, 9.16.1.3.
- guards, 3.3.4.7. , 9.8.8.
- handrails, 3.3.4.7. , 9.8.7.
- hallways, 9.5.4.1.
- height of rooms and spaces, 3.7.1.1. , 9.5.3.
- landings, 9.8.6.
- manual fire alarm stations, 3.2.4.16.
- ramps, 9.8. , 9.8.5.2.
- in self-service storage buildings, 3.9.3.1.
- shared egress facilities, 9.9.9.3.
- occupant load (for), 3.1.17.1.
- pull stations, 3.2.4.18.
- smoke alarms, 3.2.4.22. , 9.10.19.
- sound control, 3.3.4.6. , 5.9. , 9.11.
- spatial separation between houses, 9.10.15.
- sprinkler systems, 3.2.5.13.
- stairs, 3.3.4.7. , 9.8.
- travel limit to exits, 9.9.9.1.
- uniformity of runs in flights with mixed treads, 9.8.4.5.
- window areas, 3.7.2.1. , 9.7.2.3.
- window protection, 3.3.4.8.
E
- Early warning and evacuation, Table 11.4.3.3 .
Earthquake design, 4.1.8.
- accidental torsional effects, 4.1.8.1. , 4.1.8.12.
- additional performance requirements, 4.1.8.23.
- additional system restrictions, 4.1.8.10.
- analysis, 4.1.8.1. , 4.1.8.7.
- anchorage of building frames, 9.23.6.1.
- bracing to resist lateral loads, 9.23.13.
- building strength and stability, 4.1.3.2.
- deflections, 4.1.8.13.
- dynamic analysis, 4.1.8.12.
- equivalent static force analysis, 4.1.8.11.
- fasteners for sheathing or subflooring, 9.23.3.5.
- foundations, 4.1.8.15. – 4.1.8.17.
- general requirements, 4.1.8.3.
- joints in top plates of loadbearing walls, 9.23.11.4.
- masonry walls, 9.20.1.2. , 9.20.15.
- notation, 4.1.8.2.
- roof sheathing, 9.23.16.1.
- seismic force modification factors and general restrictions, 4.1.8.9.
- seismic isolation, 4.1.8.19. , 4.1.8.20.
- site designation, 4.1.8.4.
- site properties, 4.1.8.4.
- structural irregularities, 4.1.8.6. , 4.1.8.10.
- structural separation, 4.1.8.14.
- supplemental energy dissipation, 4.1.8.21. , 4.1.8.22.
- Eave projections, 3.2.3.6. , 3.2.3.16. , 9.10.14.5. , 9.10.15.5.
Eave protection, 9.26.5.
- Eavestroughs (see gutters, or roofs)
- Egress doorways, 3.3.1.5. , 3.3.1.6. , 9.9.6. , 9.9.7.3. , 9.9.8.6.
- Egress from dwelling units, 3.3.4.4. , 9.9.9.
- Ejectors for sumps, 7.4.6.3.(7)
- Electric space heating, 1.4.1.2. [A],
Electrical conductors
- Electromagnetic locking device, 3.3.1.13. , 3.4.6.16. , 3.4.6.18. , 9.9.6.7.
Electrical
- Electrical insulation at piping supports, 7.3.4.3.
- Elevating devices, 3.8.2.1. , 3.8.3.5.
- Elevator cables, 3.1.5.22.
- Elevator cars, flame-spread rating, 3.1.13.11.
Elevators, 3.1.5.22. , 3.2.6.5. , 3.2.6.7. , 3.2.8.5. , 3.3.1.7. , 3.5.1.1. , 3.5.2.1. , 3.13.8.3. , 3.13.8.4.
- barrier-free path of travel, 3.3.1.7. , 3.5.2.2. , 3.8.2.1. , 3.8.3.5.
- combustible travelling cables for elevators, 3.1.5.22.
- design, construction, installation and alteration, 3.5.
- dimensions, 3.5.4.1.
- earthquake design, 4.1.8.18.
- emergency operation, 3.2.6.4. , 3.2.7.9.
- emergency recall, 3.2.4.14. , 3.2.6.4.
- firefighters, 3.2.6.5.
- fire protection, 9.10.1.3.
- flame-spread rating, 3.1.13.7. , 3.1.13.11.
- high buildings, 3.2.6.4. , 3.2.6.5.
- hoistways, 3.2.6.4. , 3.2.6.6. , 3.2.8.4. , 3.5.3.1. , 3.5.3.3. , 3.5.4.2. , 9.10.18.4.
- limited-use/limited-application, 3.5.4.1.
- machine rooms, 3.2.1.1. , 3.2.2.14. , 3.2.5.12. , 3.5.3.3.
- not a means of egress, 9.9.2.3.
- smoke detectors, 3.2.4.11. , 3.2.4.14.
- standards, 3.5.2.1. , 3.8.3.7
- recall, 3.2.4.14. , 3.2.6.4. , 3.13.8.4.
Elevator pits, 7.4.3.6.
- drains serving 7.4.3.6.
- Enamelled fixtures, 7.2.2.2.
- Emergency cables and conductors, 3.2.7.10.
- Emergency elevators, 3.2.6.4. , 3.2.6.5. , 3.2.7.9.
- Emergency floor drains, 7.5.2.1.
- Emergency generator, 3.2.7.8. , 3.2.7.9. ,
- Emergency lighting, 3.2.7.3. , 3.2.7.4. , 3.2.7.10. , 9.9.12. , 9.9.12.3.
Emergency power supply
- Emergency return, elevators, 3.2.4.14. , 3.2.6.4.
Encapsulated mass timber construction, 3.1.6.
- building fire safety, 3.2.1.2. , 3.2.2.48. , 3.2.2.57. , 3.2.2.93.
- combustible components in exterior walls, 3.1.6.10.
- combustible elements in partitions, 3.1.6.15.
- combustible flooring elements, 3.1.6.12.
- combustible interior finishes, 3.1.6.14.
- combustible roofing materials, 3.1.6.7.
- combustible stairs, 3.1.6.13.
- combustible window sashes and frames, 3.1.6.8.
- determination of encapsulation ratings, 3.1.6.5.
- encapsulation of mass timber elements, 3.1.6.4.
- encapsulation materials, 3.1.6.6.
- exposed construction materials and components in
- concealed spaces, 3.1.6.16.
- exterior cladding, 3.1.6.9.
- materials permitted, 3.1.6.2.
- nailing elements, 3.1.6.11.
- penetration by outlet boxes, 3.1.6.17.
- spatial separation and exposure protection, 3.2.3.7. , 3.2.3.19.
- structural mass timber elements, 3.1.6.3.
- Energy efficiency, 12.2.
- Engineered wood as siding, 5.9.1.1.
- Entrances, barrier-free, 3.8.1.2.
- Environmental loads, 5.1.4.1. , 5.2.1. , 5.2.1.3. , 5.9.3.2.
Environmental separation
- air leakage, 9.25. , 9.25.3.
- application of Code, Part 5
- compliance with standards, 5.9.1.1.
- condensation control, 9.25.
- crawl spaces, 9.18.
- dampproofing, 9.13. , 9.13.2.
- fire (see Fire separations)
- heat transfer, 9.25. , 9.25.2.
- roof spaces, 9.19.
- soil gas control, 9.13. , 9.13.4.
- sound control, 5.8.1. , 9.11.
- waterproofing, 9.13. , 9.13.3.
- Entrances, barrier-free, 3.8.1.2.
Equipment, 1.2.2. [A]
- Escalators, 3.2.8.2. , 3.5.1.1. , 3.8.1.4. , 3.8.2.1. , 3.13.2.1. , 3.13.4.2.
- Evaporative air coolers, 6.3.2.16.
- Evaporative heat rejection systems, 6.3.2.15.
Excavations,
- backfill, 9.12.3.
- definition, 1.4.1.2. [A]
- depth, 9.12.2.
- design of, 4.2.4.1.
- erosion, 4.2.5.6.
- grading, 9.14.4.3.
- housing and small buildings, 9.12.
- native soil, 9.12.1.1.
- organic material, 9.12.1.1.
- protection from freezing, 9.12.1.3.
- structural design, 4.2.5.
- support of, 4.2.5.3.
- water control, 4.2.5.
- water in, 9.12.1.2.
Exhaust
- capacity, 9.32.2.3 , 9.32.3.3. , 9.32.3.4. , 9.32.3.5. , 9.32.3.6. , 9.32.3.7.
- discharge, 6.3.2.10. , 6.3.2.10. , 9.32.1.3. , 9.32.3.11. , 9.32.3.13. , 9.33.6.14A.
- ducts, 6.3.2.10.
- fans, 9.32.3.3. , 9.32.3.10.
- garages (to), 6.3.2.10.
- intakes, 6.3.2.9. , 9.32.3.3. , 9.32.3.5. , 9.32.3.7. , 9.32.3.11. , 9.32.3.13 , 9.33.6.10A.
- outlets, 6.3.2.10. , 6.3.2.10. , 9.32.3.5. , 9.32.3.13.
- systems, 3.2.6.6. , 3.2.8.7. , 3.3.1.19. , 9.32.3.4. , 9.32.3.5.
- Exhaust air openings, 6.3.2.9.
Exhaust ducts (see ducts), 3.6.3.4. , 9.10.9.20.
- combining, 6.3.2.10.
- condensation, 6.3.2.10. , 9.33.6.14A.
- connection, 6.3.2.10.
- containing air from conditioned spaces, 6.3.2.10.
- definition, 1.4.1.2. [A]
- fire dampers in, 9.10.13.13.
- fire dampers waived, 3.1.8.8.
- insulation, 6.3.2.10.
- interconnection, 6.3.2.10.
- laboratory enclosures, 6.3.4.3.
- of non-mechanical ventilating systems, 6.3.2.10.
- serving cooking equipment, 3.1.8.8. , 6.3.1.6. , 6.3.2.10. , 9.10.1.4.
- serving laundry equipment, 6.3.2.10.
- serving rooms containing WC, urinals, showers, slop sinks, 6.3.2.10.
- serving more than one fire compartment, 9.10.9.20.
- smoke dampers waived, 3.1.8.9.
- vertical service spaces, 3.6.3.4.
- Exhibition, 3.1.2.3. , 3.1.17.1. , 3.2.2.29. , 3.2.2.30 , 3.2.2.32.
- Existing buildings, application of Code, 1.3.3.3A. [A], 1.3.3.3B. [A], 1.3.3.3C. [A],
Exit
- level, 1.4.1.2.[A], 3.2.6.2.
- storey, 1.4.1.2.[A], 3.2.6.2.
Exits, 3.1.13., 3.2.4.11., 3.2.4.16., 3.2.8.4., 3.16.1.7., 3.4., 9.9.
- access, 3.4.6.18., 9.9.7.
- aggregate width, 3.4.3.1., 3.4.3.2.
- appliances, 3.4.4.4., 9.9.5.7.
- balconies, 3.4.4.1.
- capacity, 3.4.1.2., 3.4.3.1., 3.13.4.4.
- combustible glazing restrictions, 3.4.1.10.
- convergence, 3.4.1.2.
- cumulative width, 3.2.8.4., 3.4.1.2., 3.4.3.1., 3.4.3.2., 3.13.4.4.
- definition, 1.4.1.2.[A]
- distance between, 3.4.2.3.
- door hardware, 3.4.6.16.
- doors, 3.1.8.12., 3.2.3.13., 3.4.3.4., 3.4.6.11., 3.4.6.12., 3.4.6.16., 9.9.6.
- door swing, 3.4.6.12.
- ducts in, 6.9.2.4.
- dwelling units, 3.3.4.4., 9.9.9.
- emergency access, 3.4.6.18.
- emergency lighting, 3.2.7.3., 9.9.12.3.
- exterior passageways, 3.4.1.5.
- finish, interior, 9.10.17.3.
- fire alarm systems, 3.2.4.1.
- fire hose connections, 3.2.5.10.
- fire separations, 3.4.4.1., 9.9.4.2.
- floor loads, 4.1.5.3., 9.8.9.1.
- from floor areas, 9.9.8.
- general requirements, 9.9.2.
- glass block, 3.1.8.16., 9.9.4.3. – 9.9.4.6.
- glass doors, 9.6., 9.9.4.3.
- glass and transparent panels and doors, 3.4.1.8.
- guards, 3.4.6.6.
- hardware, 3.4.6.13., 3.4.6.16., 9.9.6.7.
- headroom clearance, 3.4.3.4., 9.9.3.4.
- horizontal, 1.4.1.2.[A], 3.4.1.6., 9.9.2.1.
- housing and small buildings, 9.9.
- illumination, 3.2.7.1., 9.9.11.2.
- integrity, 3.4.4.4., 9.9.2.2.
- interconnected floor space, 3.2.8.4., 3.4.3.2., 3.4.4.2.
- landings, 9.8.1.3.
- level, lowest, and smoke contamination, 3.2.6.2.
- levels, 1.4.1.2.[A], 3.2.6.2.
- lighting, 3.2.7.1., 9.9.12.2.
- loads on floor or roof, 4.1.5.3.
- lobbies (through), 3.4.4.2., 9.9.8.5.
- location, 3.4.2.5., 9.9.8.4.
- manual fire alarm stations, 3.2.4.16.
- from mezzanine, 3.4.2.2., 9.9.8.6.
- minimum number, 3.4.2.1.
- mirrors restricted, 3.4.1.9., 9.9.5.6.
- number, 3.4.2.1., 9.9.2.1., 9.9.8., 9.9.9.
- obstructions, 9.9.5., 9.9.6.1.
- obstructions permitted, 3.4.3.3., 9.9.5.5.
- protected floor space, 3.2.8.5.
- purpose, 9.9.2.2.
- ramps, 3.4.6.6., 3.4.6.7., 9.8.5.
- revolving doors, 3.4.6.15.
- rooms opening into, 3.4.4.4., 9.9.5.9., 9.9.8.5.
- secondary suites, 9.9.9.
- separation, 3.4.1.2., 3.4.4.1., 3.4.4.4.
- service rooms under, 3.6.2.2., 9.9.5.8.
- signs, 3.4.5.1., 3.4.5.2., 9.9.11.
- smoke detectors, 3.2.4.11.
- stairs, 3.4.5.3., 3.4.6.8., 3.4.6.9., 9.8.1.3., 9.8.2.1., 9.8.3.1.
- storage garages, 9.9.6.4.
- storeys, 1.4.1.2.[A], 3.2.6.2.
- tactile signs, 3.4.5.2., 3.4.6.16., 3.4.6.18., 3.8.3.18.
- travel distance, 3.4.2.1., 3.4.2.3. – 3.4.2.5., 9.9.8.1., 9.9.8.2.
- types, 3.4.1.4., 9.9.2.1.
- visibility, 9.9.11.2.
- wall openings near, 9.9.4.4.
- weather protection, 3.4.6.11.
- width, 3.4.3, 9.9.3.2., 9.9.8.3.
- windows, 3.2.3.13., 9.6.1.4., 9.9.4.
- wired glass in, 3.2.3.13., 3.4.4.4., 9.9.4.3. – 9.9.4.6.
Expansion and contraction
- elements in environmental separators, 5.2.2.1.
- heating and cooling systems, 6.2.1.3., 9.33.4.6., 9.33.8.1.
- metal and vinyl siding, 9.27.5.6.
- piping, 6.7.1.1., 7.3.3.9.
- structural, 4.1.2.1.
- Explosion venting, 3.3.1.21.
Exposing building face, 3.1.5.5., 3.2.3.2., 3.2.3.3., 3.2.3.7., 3.2.3.10. – 3.2.3.12., 3.2.3.14., 9.10.14., 9.10.15.
- area, 3.2.3.2., 9.10.14.2., 9.10.15.2.
- area and location, 9.10.14.2., 9.10.15.2.
- construction, 3.2.3.7., 9.10.14.5., 9.10.15.5.
- definition, 1.4.1.2.[A]
- exits, 3.2.3.13.
- fire resistance waived, 9.10.14.5., 9.10.15.5.
- first storey facing a street, 9.10.14.4.
- garage serving a dwelling unit, 9.10.14.5., 9.10.15.5.
- glazed openings, 9.10.15.4.
- limiting distance, 3.2.3.5., 3.2.3.6., 3.2.3.7., 9.10.14.5., 9.10.15.5.
- low-hazard industrial occupancy (Group F, Division 3), 3.2.3.11.
- in noncombustible construction, 3.1.5.5.
- protection of, 3.2.3.8.
- restrictions on combustible projections, 3.2.3.6., 9.10.14.5., 9.10.15.5.
- spatial separation between buildings, 9.10.14., 9.10.15.
- structural members, 3.2.3.9.
- unlimited openings, 3.2.3.10., 9.10.14.4., 9.10.15.4.
- unprotected openings, 3.2.3.1., 3.2.3.7., 3.2.3.10., 3.2.3.12., 9.10.14.4.
- Exposure of materials, 7.2.1.1.
- Exterior areas, loads on, 4.1.5.5.
- Exterior insulation finish systems, 5.9.4., 9.27.14.
Exterior ornamentations
- earthquake loads, 4.1.8.1., 4.1.8.18.
- wind loads, 4.1.7.11.
- Exterior walks, barrier-free path of travel, 3.8.3.2.
Exterior walls
- fire-resistance rating, 3.1.7.2., 3.1.7.3., 3.2.3.7., 9.10.3.1., 9.10.3.3., 9.10.14.5., 9.10.15.5.
- radiation, 3.1.7.2., 9.10.3.3.
- restrictions on combustible projections, 3.2.3.6., 9.10.14.5., 9.10.15.5.
- Extinguishers, portable, 3.2.5.16., 3.9.3.5., 9.10.20.4., 9.10.21.8.
- Extracted tees, 7.3.3.2.
F
- Fabrics, for canopies and marquees, 3.1.16.1. , 3.14.1.6.
Factories
- Factory-built chimneys, 1.4.1.2. [A], 9.21.1.3.
- Factory-constructed buildings, 1.1.1.1. [A]
- Falsework, 4.1.1.3.
Fans, 3.2.6.2. , 3.2.7.9. , 3.2.8.7. , 6.3.2.17.
- access, 6.2.1.6.
- auxiliary, 9.32.3.7.
- bathrooms, 9.32.3.7.
- capacity, 9.32.3.3. – 9.32.3.7. , 9.32.3.10.
- controls, 9.32.3.3.
- dehumidistat, 9.32.3.3. , 9.32.3.7.
- emergency power supply, 3.2.7.9.
- emergency stoppage, 3.2.6.2.
- exhaust, 6.3.2.10. , 9.32.1.3. , 9.32.3.1. , 9.32.3.4. – 9.32.3.5. , 9.32 , 3.7. , 9.32.3.11.
- housing and small buildings, 9.32.
- installation, 6.3.2.17. , 9.32.3.2.
- kitchens, 9.32.3.10.
- location, 6.3.2.17.
- noise, 9.32.3.10.
- range-top (cooktop), 9.32.3.7. , 9.32.3.10.
- sound ratings, 9.32.3.10.
- standards for, 9.32.3.10.
- supplementary exhaust, 9.32.3.7.
- supply, 9.32.3.5. , 9.32.3.6. , 9.32.3.8. , 9.32.3.10.
- vibration, 9.32.3.2.
Farm buildings, 3.18.1.1. , 9.41.1.1. , 12.2.1.2. , 12.2.2.1. , 12.2.3.1.
- application of Code, 1.3.3.1A. [A], 2.1.2.
- definition, 1.4.1.2. [A]
- automatic sprinkler systems, 2.2.4.2.
- classification, 2.1.4.1.
- change of use, 10.1.1.2. , 10.3.2.1. , 10.3.2.2.
- dangerous goods storage, 2.2.8.7.
- design of bins and silos, 2.3.1.1.
- electrical wiring and equipment, 2.2.1.15.
- exhaust ventilation and explosion venting, 2.2.8.2.
- farm machinery and vehicles, 2.3.2.4.
- fire detectors, 2.2.3.7.
- geotechnical design parameters, 2.3.1.1.
- liquid manure storage tanks, 2.2.8.5. , 2.3.1.1. , 2.3.2.5.
- loads due to earthquakes, 2.3.4.
- loads due to snow, 2.3.3.
- loads due to use and occupancy, 2.3.2.
- loads supported on a floor or suspended from a ceiling, 2.3.2.1.
- location of heating appliances, 2.4.3.1.
- means of egress, 2.2.6.1.
- minimum lighting requirements, 2.2.5.1.
- occupant load, 2.2.1.17.
- required ventilation, 2.4.2.1
- renovation, 11.4.1.1. , 11.4.2.3.
- separation of occupancies, 27.2.1.4.
- small farm buildings, 2.1.2.3.
- unobstructed slipper roofs, 2.3.3.1.
Fasteners
Fastening
- cladding, 9.27.5.4. , 9.27.5.7.
- furring, 9.29.3.2.
- gypsum board, 9.29.5.8. , 9.29.5.9.
- hardboard finish, 9.29.7.3.
- plywood finish, 9.29.6.3.
- sheathing, 9.23.3.5.
- shingles, 9.26.7.4. – 9.26.7.6. , 9.26.8.4. , 9.26.8.5.
- siding, 9.27.5.4.
- steel framing, 9.24.3.6.
- steel studs (to), 9.24.1.4.
- stucco lath, 9.28.4.6.
- subflooring, 9.23.3.5.
- underlay, 9.30.2.3.
- wood frame construction, 9.23.3.
- wood shingles and shakes, 9.26.9.5. , 9.26.10.4.
- Ferrous pipe and fittings, 7.2.6.
- Faucets and other bathroom accessories, 3.8.3.8. , 3.8.3.12. , 3.8.3.16.
Fenestration (see also Windows)
Fibreboard
- fastening, 9.23.3.5. , 9.29.8.3.
- installation, 9.29.8.3. , 9.29.8.4.
- as insulating finish, 9.29.8.
- material standard, 9.29.8.1.
- nailing, 9.29.8.3.
- as roof sheathing, 9.23.16.7.
- thickness, 9.29.8.2.
- wall sheathing, 9.23.17.2. , 9.23.17.3. , 9.23.17.5.
Fill (see also Backfill),
- Filters, air, 6.3.2.13. , 9.33.6.14.
- Final tests, 7.3.6.1. , 7.3.6.2. , 7.3.6.6.
Fire alarm and detection systems, 3.2.4. , 3.2.6.8. , 3.2.7.8. , 9.10.18.
- annunciators, 3.2.4.8.
- audibility, 3.2.4.18.
- audible alert and alarm signals, 3.2.4.17.
- central alarm and control facility, 3.2.6.7.
- central vacuum shutdown, 3.2.4.13.
- continuity, 3.2.4.2.
- design, 9.10.18.3.
- and door hold-open devices, 3.1.8.14.
- electrical supervision, 3.2.4.9.
- emergency power supply, 3.2.7.
- fire detectors, 3.2.4.4. , 3.2.4.10.
- fire separations for, 3.6.2.8.
- heat detectors, 3.2.4.11. , 9.10.18.
- hold-open devices, 3.1.8.11.
- installation, 3.2.4.5. , 9.10.18.3.
- manual stations, 3.2.4.16.
- requirements, 9.10.18.
- residential fire warning systems, 3.2.4.21. , 9.10.19.8.
- signal devices, 3.2.4.17. , 3.2.4.18. , 3.2.4.19.
- signal to fire department, 3.2.4.7.
- silencing, 3.2.4.6.
- single stage systems, 3.2.4.3. , 3.2.4.4. , 3.2.4.7.
- smoke alarms, 3.2.4.20.
- smoke alarms interconnection, 9.10.19.5.
- smoke detectors, 3.2.4.11. , 3.2.4.12. , 9.10.18. , 9.10.18.5.
- sprinkler systems, 3.2.4.8.
- testing, 3.2.4.5.
- two stage systems, 3.2.4.3. , 3.2.4.4. , 3.2.4.8.
- types, 3.2.4.3.
- central vacuum systems, 9.10.18.7.
- verification, 3.2.4.5.
- visual signal devices, 3.2.4.19. , 3.2.4.21. , 3.2.4.20.
- voice communication systems, 3.2.4.22. , 3.2.4.23.
- waterflow trigger, 3.2.5.14.
- where required, 9.10.18.
- Fire and sound resistance of walls, floors and ceilings, 3.1.7.1. , 3.3.4.6. , 9.10.3.1. , 9.11.
Fire blocks,
- in concealed spaces, 3.1.11. , 3.1.11.5. , 9.10.16.
- in crawl spaces, 3.1.11.6.
- definition, 1.4.1.2. [A]
- in eave overhangs, 3.2.3.16.
- in encapsulated mass timber construction, 3.1.11.3. , 3.1.11.5. , 3.1.11.7.
- in floor assemblies, 3.1.11.5.
- in mansard and gambrel roofs, 3.1.11.5. , 9.10.16.1.
- materials, 3.1.11.7. , 9.10.16.3.
- in noncombustible construction, 3.1.5.2. , 3.1.11.3.
- pipes and ducts in, 9.10.16.4.
- in roof assemblies, 3.1.11.5. , 3.1.11.7.
- between vertical and horizontal spaces, 3.1.11.4.
- in walls/wall assemblies, 3.1.11.2. , 9.10.16.2
Fire chambers, 9.22.4.
- dimensions, 9.22.4.1.
- Fire compartments, 1.4.1.2. [A], 3.1.8.6. , 3.1.8.13. , 3.1.9.4. , 3.2.1.5. , 3.2.3.1. , 3.2.3.2. , 3.2.3.12. , 3.2.3.13. , 3.2.4.8. , 3.2.5.14. , 3.6.3.4.
- Fire curtains, 3.3.2.14.
Fire dampers
- Fire department, 3.2.4.7. , 3.2.4.8. , 3.2.5.4. – 3.2.5.6. , 3.2.6.5. – 3.2.6.7.
- Fire department connection to buildings, 3.2.5.5. , 3.2.5.15.
- Fire detectors, 1.4.1.2. [A], 3.2.4.4. , 3.2.4.10.
Fire escapes, 3.4.1.4. , 3.4.7. , 9.9.2.1.
- access, 3.4.7.3.
- balconies, 3.4.7.3.
- closures, 3.4.7.4.
- construction, 3.4.7.2.
- dwelling units, 3.4.7.3.
- existing buildings, 3.4.7.1. , 9.9.2.3.
- guards, 3.4.7.6.
- handrails, 3.4.7.6.
- headroom, 3.4.7.5.
- landings, 3.4.7.7.
- loads on, 4.1.5.3.
- means of egress, 9.9.2.4.
- protection of, 3.4.7.4.
- scope of Code, 3.4.7.1.
- stairs, 3.4.7.5.
- Fire extinguishers, (see extinguishers, portable)
- Fire extinguishing systems, industrial occupancies, 3.3.5.2.
- Firefighters, 3.2.6.2. , 3.2.5.5. , 3.2.6.5. – 3.2.6.7. , 3.2.6.17.
Firefighting
- Firefighting services (see Fire department)
- Fire hose cabinets, 3.2.5.11.
- Fire hose nozzles, 3.2.5.11.
- Fire hose stations, 3.2.5.11. , 9.10.21.9.
- Fire load, 1.4.1.2. [A], 3.2.2.91. , 3.2.3.11.
Fireplaces, 3.6.2.1. , 6.9.4.2. , 9.22. , 9.32.3.8.
- chimneys, 9.21.2.4.
- clearances, 9.22.9.
- combustion air, 9.22.1.4.
- concrete materials, 9.22.1.2.
- dampers, 9.22.6.1.
- factory-built, 9.22.8.
- fire chamber, 9.22.4.
- footings, 9.22.1.3.
- hearth, 9.22.5.
- housing and small buildings, 9.22. , 9.33.5.4.
- inserts, 9.22.10.
- liners, 9.22.2. , 9.22.3.
- masonry materials, 9.22.1.2.
- openings, 9.22.4.1.
- protection against depressurization, 9.32.3.8.
- smoke chambers, 9.22.7.
- walls, 9.22.3
Fire protection, 3.2.3.8. , 3.2.5. , 9.10.
- building classification, 3.1.2.
- combustible construction, 3.1.4.
- commissioning of life safety and fire protection systems, 9.10.18.10.
- construction camps, 9.10.21.
- cooktops, 9.10.22.
- crawl spaces, 9.18.7.
- dwelling units, 9.10.
- electric ranges, 9.10.22.
- electrical conductors, 3.2.7.10.
- exceptions, 3.2.2.3.
- exits, 9.9.4.
- fire-resistance ratings, 3.1.7.
- fire safety plan, 1.1.4.
- gas ranges, 9.10.22.
- limiting distance and spatial separation between buildings, 3.2.3.1.
- multiple occupancy requirements, 3.1.3.
- noncombustible construction, 3.1.5.
- ovens, 9.10.22.
- penetrations in fire separations and fire-rated assemblies, 3.1.9.1.
- propane ranges, 9.10.22.
- structural members, 3.2.3.9.
- testing of integrated fire protection and life safety systems, 9.10.1.2.
- tests, 3.2.9.1.
Fire-protection rating
- of closures, 3.1.8.4. , 3.1.8.5.
- definition, 1.4.1.2. [A]
- of doors, 3.1.8.12.
- exceptions, 9.10.13.2. , 9.10.13.5. , 9.10.13.7.
- of fire dampers, 3.1.8.7.
- tests, 3.1.8.4. , 9.10.3.1.
- Fire protection systems, 3.2.5.17.
- Fire pumps, 3.2.5.18.
Fire-resistance rating, 3.1.7. , 3.2.3.7.
- about, 9.10.3.
- arena-type building roof assemblies, 3.2.2.17.
- ceilings construction, 9.10.3.4.
- definition, 1.4.1.2. [A]
- determination, 3.1.7.1. , 9.10.3.1.
- doors, 5.3.1.2.
- encapsulated mass timber construction, 3.1.7.5.
- exemptions, 3.1.7.2. , 9.10.8. , 9.10.8.11.
- exits, 9.9.4.2.
- exposing building face, 3.2.3.7.
- exterior walls, 3.1.7.3. , 3.2.3.7. , 9.10.3.3.
- fire separations, 3.1.7.3
- firewalls, 3.1.7.3. , 3.1.10.2. , 9.10.3.3.
- floor assemblies, 3.1.7.3. , 3.2.1.4. , 9.10.3.1. , 9.10.8. , 9.10.9.4.
- grease duct enclosures, 3.6.3.5.
- interior walls, 3.1.7.3. , 9.10.3.3.
- loadbearing walls, 3.1.7.5. , 9.10.8.3.
- membrane ceilings, 9.10.3.4.
- minimum, 3.1.7.4.
- rating of walls, floors, ceilings, 9.10.3.3.
- relation to occupancy and height, 9.10.8.
- roofs, 9.10.8.
- separations of suites, 3.3.1.1. , 9.10.9.14. , 9.10.9.15. , 9.10.9.16.
- steel framing, 9.24.2.4. , 9.24.3.2.
- support of assemblies having, 9.10.8.3.
- supporting construction, 3.1.7.5. , 9.10.8.3.
- test methods, 3.1.7.1. , 9.10.3.1.
- vertical fire separations 1.3.3.4. [A], 9.10.3.3.
- waived, 3.2.2.17. , 9.10.8.2. , 9.10.14.5 , 9.10.15.5.
- walls, 9.10.3.3.
- walls, exterior, 3.1.7.2. , 3.1.7.3. , 3.2.3.7. , 3.2.3.11. , 9.10.3.1. , 9.10.3.3. , 9.10.14.5. , 9.10.15.5.
- walls, interior, 9.10.3.1. , 9.10.3.3.
- walls, loadbearing, 3.1.7.5. , 9.10.8.3.
- windows, 5.3.1.2.
Fire-retardant treated wood (see also Wood, fire-retardant
Fire safety
Fire separations,
- airtightness of windows and doors in, 5.4.1.2. , 5.9.2.3.
- barrier-free floor areas, 3.3.1.7.
- between openings, 3.2.3.17.
- between zones in hospitals or nursing homes, 3.3.3.5.
- boarding and lodging houses, 9.10.9.16.
- building face (on), 3.2.3.2.
- building services, 3.1.9.1. , 3.1.9.3. , 3.1.9.4. , 9.10.9.6.
- business and personal services occupancy, 3.3.1.1.
- care or detention occupancy, 3.3.3.2.
- closures, 3.1.8.1. , 3.1.8.5. , 9.10.13.
- in combustible construction, 3.1.8.2.
- construction camps, 9.10.21.2.
- containment in basements, 3.2.1.5.
- continuity, 3.1.8.3. , 9.10.9.2. , 9.10.11.2.
- crawl spaces, 3.2.2.9. , 9.10.9.4.
- definition, 1.4.1.2. [A]
- and door hold-open devices, 3.1.8.14.
- dumb waiters, 3.5.3.2.
- dwelling units, 3.1.3.1. , 3.3.4.2. , 9.10.9.13. , 9.10.9.14. , 9.10.9.16.
- elevator machine rooms, 3.5.3.3.
- elevators, 3.2.6.5. , 3.5.3.1.
- exits, 3.4.4.1. , 9.9.4.
- fire dampers in, 3.1.8.7.
- fire-resistance rating, 3.1.7.3.
- firestops, 3.1.9.1.
- firewalls, 3.1.10.2. , 9.10.11.
- floor assemblies, 3.2.2. , 3.3.4.2.
- floors over basements, 3.2.1.4.
- garages, 3.3.5.5. , 3.3.5.6. , 9.10.4.3. , 9.10.9.18. , 9.10.9.19.
- grease duct enclosures, 3.6.3.5.
- hold-open devices, 3.1.8.12.
- horizontal, 3.1.8.8.
- in horizontal service spaces, 3.1.8.3. , 3.6.4.2. , 9.10.9.12.
- industrial occupancy (Group F), 9.10.9.14. , 9.10.9.15. , 9.10.9.18. , 9.10.9.19.
- integrity, 9.10.9.2.
- interconnected floor spaces, 9.10.9.5.
- interior walls, 9.10.3.3.
- laboratory ventilation enclosures, 3.3.1.21
- libraries, 3.3.2.13.
- major occupancy, 3.1.3.1. , 9.10.9.13. , 9.10.9.14.
- meeting of two exterior walls, 3.2.3.14. , 9.10.12.3.
- mercantile occupancy (Group E), 3.1.3.1. , 3.3.1.1.
- mezzanines, 3.1.3.1. , 3.2.8.1.
- multiple occupancies, 3.1.3.1. , 9.10.9.15. ,
- between openings, 3.2.3.17.
- openings in, 3.1.8.1. , 3.1.8.6. , 3.1.8.14. , 3.2.8. , 9.10.13. , 9.24.3.7.
- openings protected by glass blocks or wired glass, 3.1.8.16.
- operating, recovery and delivery rooms, 3.3.3.6.
- penetrations, 3.1.9.3.
- process plants, 3.3.6.9.
- protected floor spaces, 3.2.8.4.
- public corridors, 3.3.1.4. , 9.10.9.17.
- rating, 3.1.7.3. , 9.10.3.
- repair garages, 3.3.5.5. , 9.10.9.19.
- residential occupancy (Group C), 3.1.3.1. , 3.2.2.47. 3.2.2.55. , 3.2.2.93. , 3.3.4.2. , 9.10.9.13. , 9.10.9.14. , 9.10.9.16.
- roof-top enclosures, 3.2.2.14.
- between rooms and spaces within buildings, 9.10.9.
- secondary suites, 9.10.9.4. , 9.10.9.16. , 9.10.9.17. , 9.10.10.4. , 9.10.11.2. , 9.10.12.3.
- self-closing devices, 3.1.8.11.
- self-service storage buildings, 3.10.3.1.
- service penetrations, 3.1.9.1. – 3.1.9.4. , 9.10.9.6.
- service rooms, 3.6.2.1. , 9.10.10.
- soffit protection, 9.10.12.4.
- stages, 3.3.2.12.
- steel framing, 9.24.2.4. , 9.24.3.7.
- storage of dangerous goods, 3.3.6.2.
- storage garages, 3.2.1.2. , 3.3.4.2. , 3.3.5.6. , 9.10.9.18.
- storage rooms, 3.3.4.3. , 3.6.2.5.
- storeys below ground, 3.2.2.15.
- suites, 3.3.1.1. , 9.10.9.14. – 9.10.9.16.
- theatre stages, 3.3.2.14.
- thermal breaks in windows and doors in, 5.3.1.2.
- temperature rise and area limits, 3.1.8.15. , 3.1.8.17.
- twenty-minute closures, 3.1.8.12.
- vehicular passageways, 3.2.3.18.
- vertical, 1.3.3.4. [A], 3.1.8.3. , 3.1.8.8.
- vertical service spaces, 3.6.3.1.
- in vertical shafts, 3.1.8.3.
- vestibules, 3.2.8.4. , 3.2.8.5.
- walkways, 3.2.3.19. , 3.2.3.20.
- wall exposed to another wall, 3.2.3.14.
- watertightness of windows and doors in, 5.9.2.3.
- between zones in hospitals or long-term care, 3.3.3.5
- Fire service mains, 7.2.11.
- Fire service pipes, 1.4.1.2. [A], 7.6.2.4.
- Fire stop flaps, 1.4.1.2. [A], 3.6.4.3. , 9.10.13.14.
- Fire stopping, 1.4.1.2. [A], 3.1.5.2. , 3.1.5.19. , 3.1.9.1. , 3.1.9.3. – 3.1.9.5. , 3.1.11.7. , 3.6.4.3. , 9.10.9.6.
Firewalls, 1.3.3.4. [A], 3.1.9.1. , 3.1.10. , 3.2.4.2. , 9.10.11.
- combustible projections, 3.1.10.7.
- construction, 9.10.11.3.
- continuity, 3.1.10.3.
- definition, 1.4.1.2. [A]
- exterior walls, 3.1.10.6.
- exemptions, 9.10.11.2.
- exterior walls meeting, 3.1.10.6.
- and fire alarm systems, 3.2.4.2.
- fire-resistance rating, 3.1.7.3. , 3.1.10.2. , 9.10.3.3. , 9.10.11.3.
- maximum openings in, 3.1.10.5.
- mezzanines, 3.2.8.1.
- parapets, 3.1.10.4.
- party walls as, 9.10.11.1.
- penetrations in, 3.1.9.1.
- separating buildings, 1.3.3.4. [A]
- structural stability, 3.1.10.1. , 4.1.5.17.
- support of, 3.1.10.1.
- First storey, 1.4.1.2. [A], 3.2.2.15. , 3.2.5.1. , 3.2.8.2. , 9.9.4.7.
- 90° elbows, 7.2.4.3.
- ABS, 7.2.5.9.
- acid and corrosive, 7.2.8.1.
- brass or bronze, 7.2.7.2., 7.2.7.3.
- butt-fusion (polyethylene), 7.2.5.5.
- cast iron, 7.2.6.1., 7.7.6.2., 7.2.6.5.
- cellular core PVC, 7.2.5.16.
- cleanouts, 7.2.10.3., 7.4.7.1., 7.4.7.4.
- composite, 7.2.5.13., 7.2.5.14.
- concrete, 7.2.5.3.
- corrosion-resistant, 7.2.8.1.
- couplings, 7.2.6.8., 7.2.10.4., 7.3.2.6.
- CPVC hot and cold water pipe, 7.2.5.7.
- cross, 7.2.4.1.
- crosslinked polyethylene, 7.2.5.6.
- drainage, 7.5.4.3.
- ferrous, 7.2.6.
- fibrocement, 7.2.5.1.
- flanged, 7.2.7.2.
- flared joint, 7.2.7.7.
- hub and spigot, 7.3.2.1.
- increasers, 7.3.3.5.
- installation of pipe, 7.3.2.1.
- lead, 7.2.7.8.(1)
- malleable iron, 7.2.6.6.
- marking of, 7.2.1.3.
- minimum pressure, 7.2.1.5.
- non-ferrous, 7.2.7.
- non-metallic, 7.2.5.
- PE/AL/PE, 7.2.5.12.
- PE-RT, 7.2.5.15.
- PEX/AL/PEX, 7.2.5.13.
- plastic, 7.2.5.9. , 7.2.5.10. , 7.2.5.12.
- polyethylene, 7.2.5.4.
- polypropylene, 7.2.5.14.
- PVC, 7.2.5.7.
- reducers, 7.3.3.5.
- restrictions on use of, 7.2.4. , 7.2.5.2. , 7.2.5.3.(4) , 7.2.5.16. , 7.2.5.4. , 7.6.4.1.
- sanitary, T, 7.2.4.2.
- screwed and threaded, 7.2.6.3. , 7.2.6.5. , 7.2.6.6. , 7.2.7.3.
- shower valves, 7.6.4.1. , 7.6.5.2.
- solder-joint, 7.2.7.5. , 7.2.7.6.
- supply and waste, 7.2.10.6. , 7.6.4.1.
- stainless steel butt weld, 7.2.6.11.
- stainless steel threaded, 7.2.6.13.
- T, 7.2.4.1.
- used in buildings, 7.2.5.11.
- used underground, 7.2.5.9.
- vitrified clay, 7.2.5.4.
- Fixed seats, 3.3.2.4.
Fixtures, 7.2.2.
- connections of, 7.4.2.1. , 7.4.2.3.
- construction of, 7.2.2.
- definition, 1.4.1.2. [A]
- hydraulic load from, Table 7.4.9.3 ., 7.4.10.
- indirectly connected, 7.3.3.11. , 7.4.2.1.(1)
- installation of, 7.1.6.1. , 7.3.4.1. , 7.4.3.1.
- location of, 3.7.6.3. , 7.1.6.1. , 7.1.6.2. , 7.4.3.
- specifications for, 7.2.2. , 7.6.4.2.
- used, 7.2.1.2.
Fixture drains
- cleanouts for, 7.4.7.1.
- connections to circuit vents, 7.5.3.1.
- connections of, to wet vents, 7.5.2.1.
- definition, 1.4.1.2. [A]
- directly connected, 7.4.2.3.
- fixture traps for, 7.5.6.1.(1)
- for floor outlet fixtures, 7.3.3.8.
- indirectly connected, 7.3.3.11.
- minimum slope of, 7.4.8.1.
- protection of, from backflow, 7.4.6.4.(2)
- size of, Tables 7.4.10.2. , 7.4.10.5.
- venting of traps for, 7.5.1.1.
Fixture outlet pipes definition, 1.4.1.2. [A]
- as cleanouts, 7.4.7.1.
- developed length of, 7.4.8.2.
- directly connected, 7.4.2.3.
- for indirectly connected fixtures, 7.4.2.3.(2)
- size of, 7.4.9.3.
Fixture units
- Fixed seats, bench type without arms, 3.3.2.8.
Flame-spread rating, 3.1.5.12. , 3.1.5.19. , 3.1.5.20. , 3.1.13. , 9.10.17. , 9.10.21.6.
- bathrooms, 3.1.13.3.
- bathrooms within suites of residential occupancy, 3.1.13.3. , 9.10.17.11.
- business and personal services occupancy, 9.10.17.
- combustible glazing, 3.1.5.4.
- combustible insulation, 3.1.4.2. , 3.1.5.14. , 9.10.17.10.
- combustible piping, 3.1.5.20.
- combustible skylights, 3.1.5.4. , 9.10.17.9.
- corridors, 9.10.17.2. , 9.10.17.5.
- crawl spaces, 9.18.7.1.
- definition, 1.4.1.2. [A]
- determination, 3.1.12.1. , 9.10.3.2.
- diffusers and grills, 6.3.2.9. , 9.33.6.10.
- doors, 3.1.13.2. , 9.10.17.1.
- ducts, sealants, linings and coverings, 3.6.5.4. , 6.3.2.3. , 9.10.17.12. , 9.33.6.10 , 9.33.6.13
- elevator cars, 3.1.13.7. , 3.1.13.11.
- exits, 3.1.13.2. , 3.1.13.7. , 3.1.13.8. , 9.10.17.2. , 9.10.17.3.
- exterior exit passageways, 3.1.13.10. , 9.10.17.4.
- fire-retardant treated wood, 3.1.4.5.
- firewalls, 9.10.11.3.
- foamed plastic insulation, 3.1.4.2. , 3.1.5.14. , 9.10.17.10.
- glazing and skylights, 3.1.5.4. , 3.1.13.2. , 9.10.17. , 9.10.17.1. , 9.10.17.6. , 9.10.17.9.
- gypsum board, 9.29.5.2.
- high buildings, 3.1.13.7.
- industrial occupancy, 9.10.17.
- insulation, 3.1.5.14. , 9.10.17.10. , 9.25.2.2.
- insulation in concealed spaces, 9.10.17.
- insulation in noncombustible construction, 3.1.5.14. , 3.1.5.15.
- interior finishes, 3.1.5.12. , 3.1.13.1. , 9.10.17.
- light diffusers and lenses, 3.1.13.4. , 9.10.17.6. , 9.10.17.8.
- lobbies, 3.1.13.2.
- mercantile occupancy, 9.10.17.
- pipe insulation and coverings, 6.5.1.1.
- public corridors, 3.1.13.6. , 9.10.17.2. , 9.10.17.5.
- residential occupancy, 3.1.13.2. , 3.1.13.3. , 3.1.13.7.
- service rooms, 3.1.13.7.
- skylights, 3.1.5.4. , 3.1.13.2. , 9.7.2.2. , 9.10.17. , 9.10.17.1. , 9.10.17.6. , 9.10.17.9.
- tests, 3.1.12.1. , 9.10.3.2.
- vehicular passageways, 3.1.13.2.
- ventilated laboratory enclosures, 6.3.4.4.
- vestibules, 3.1.13.7.
- windows, 9.7.2.2.
- Flared joints, 7.3.2.5.
- Flared joint fittings, 7.2.7.7. , 7.3.3.12.
- Flammable gases (see Combustible gases)
Flammable liquids
Flashing, chimney, 9.26.4.6.
- caps, 9.21.4.6.
- junctions with other materials, 9.21.4.10.
- Flashing, doors, 9.7.6.2.
Flashing, roof, 5.6.2.1. , 9.26.4.
- built-up-roofing at cant strips, 9.26.11.10.
- built-up-roofing to masonry, 9.26.4.6.
- built-up-roofing to other than masonry, 9.26.4.7.
- at intersections, 9.26.4.
- materials, 9.3.3.2. , 9.26.4.2.
- protection, 9.26.1.2.
- sealing and drainage, 5.6.2.1.
- shingles to masonry, 9.26.4.4
- shingles to other than masonry, 9.26.4.4.
- valley, 9.26.4.3.
- Flashing vent pipe, 7.2.10.14. , 7.5.6.5.
- Flashing, skylights, 9.7.6.2.
Flashing, wall, 5.6.2.1. , 9.27.3.
- cavity walls, 9.20.13.3. , 9.20.13.6.
- fastening, 9.20.13.2.
- installation, 9.20.13.3. , 9.20.13.4. , 9.27.3.1.
- masonry veneer, 9.20.13.5. – 9.20.13.7.
- masonry walls, 9.20.13.
- materials, 9.3.3.2. , 9.20.13.1. , 9.27.3.7.
- sealing and drainage, 5.6.2.1.
- stucco, 9.28.1.5.
- Flashing, windows, 9.7.6.2. , 9.20.13.3. , 9.20.13.4.
- Flash point, 1.4.1.2. [A]
- Flat roofs, wind loads, 4.1.7.6.
- Flat wall insulating concrete forms, 5.9.1.1.
- Flexible water connectors, 7.2.10.18.
- Flight, 1.4.1.2. [A] (see also Stairs)
Floor areas, 9.5.1.1A.
- barrier-free design, 9.5.2.
- barrier-free path of travel, 3.3.1.7.
- care or detention occupancy, 3.3.3.
- combination rooms, 9.5.1.2.
- definition, 1.4.1.2. [A]
- emergency access, 3.4.6.18.
- general requirements, 3.3.1.
- occupant load, 3.1.17. , 9.9.1.3.
- self-service storage buildings, 3.10.2.4.
- separation of suites, 3.3.1.1.
- termination, 9.10.12.1.
Floor drains (see also drains)
- Floor outlet fixtures, drain connections, 7.3.3.8.
Flooring, 9.30.
- ceramic tile, 9.23.15.5. , 9.30.6.
- dangerous goods, 3.3.6.7.
- parquet, 9.30.4.
- resilient, 9.23.15.6. , 9.30.5.
- supports, 9.30.1.3.
- underlay, 9.30.2.
- water resistant, 9.30.1.2.
- wood strip, 9.23.15.5. , 9.30.3.
Floor numbers, 9.9.11.5.
Floors
- acting as diaphragms, 4.1.8.15.
- air barrier systems, 9.25.3.
- anchorage of intersecting, 9.20.11.1.
- cantilevered, 9.23.9.9.
- combustible elements permitted, 3.1.5.8.
- concrete topping, 9.23.4.4.
- construction camps, 9.10.21.3.
- dampproofing, 9.13.2.1.
- drains, 9.31.4.3.
- fire separations, 9.10.9.4.
- framing, 9.23.4.
- fire-resistance rating, 9.10.8.1.
- garages, 9.35.2.2.
- heavy timber construction, 3.1.4.7.
- joists, 9.23.4.1. , 9.23.4.4. , 9.23.9.
- loads due to use of, 4.1.5.
- loads on, 9.23.1.1. , 9.23.4.1. , 9.23.4.2. , 9.23.4.4.
- loads, 4.1.5. , 9.23.1.1. , 9.4.
- ratings, 9.10.3.1.
- subfloors, 9.23.15.
- supports, 3.1.4.6. , 3.2.1.4.
- thermal insulation, 9.25.1.1.
- vibrations, 4.1.3.6.
Floors-on-ground, 9.16.
- Flow, peak demand, 7.6.3.1. , 7.6.3.4.
- Flow control roof drain, 1.4.1.2. [A], 7.4.10.4.
- Flue (see also Flues, chimney), 1.4.1.2. [A]
- Flue collars, 1.4.1.2. [A]
- Flue pipes, 1.4.1.2. [A], 9.21.1.3. , 9.21.1.4.
Flues, chimney, 9.21.2.
- Flush cycle, 7.6.4.2.
- Flushing devices, 7.2.10.8. , 7.6.1.6. , 7.6.1.11.
- Fluxes, 7.2.9.2.
- Food premises, 3.7.6. , 9.1.1.6.
- Food preparation sinks, overflows, 7.2.2.4.
- Footbridges, 4.1.5.3.
Footings, 9.15.
- area and width, 9.15.3.3. – 9.15.3.7.
- chimneys, 9.15.3.1. , 9.21.4.3.
- design, 9.4.4.1.
- dimensions, 9.15.3.
- drainage, 9.14.
- fireplaces, 9.15.3.1. , 9.22.1.3.
- granular drainage layer, 9.14.4.
- housing and small buildings, 9.15.
- insulating concrete forms, 9.15.3.5.
- non-loadbearing masonry walls, 9.15.3.5. , 9.15.3.6.
- projections, 9.15.3.8.
- size, 9.15.3.
- stepped, 9.15.3.9.
- strip sizes, for exterior walls, 9.15.3.4. , 9.15.3.5.
- thickness, 9.15.3.8.
- trenches, 9.12.4.1.
- width, 9.15.3.3. , 9.15.3.4. , 9.15.3.5. , 9.15.3.6. , 9.15.3.8.
- Forced-air furnace, 1.4.1.2. [A]
- Forced-air heating systems (see also Ducts, Heating systems and equipment)
- Formwork, 4.1.1.3.
- Foundation unit, 1.4.1.2. [A]
- adfreezing, 1.4.1.2. [A], 4.2.4.4.
- backfilling, 4.2.5.8.
- cottages, 9.37.2.2.
- capacity in weaker soil or rock, 9.4.4.2.
- of concrete, 4.2.3.5. , 9.3.1.6. , 9.3.1.7. , 9.15.1.1. , 9.15.2. , 9.15.4.
- of concrete block, 9.15.4.2.
- dampproofing, 9.13.2.
- deep, 1.4.1.2. [A], 4.2.7.
- definition, 1.4.1.2. [A]
- deformation-resistant buildings, 9.12.2.2. , 9.15.1.3.
- depth, 9.12.2.
- design, 4.1.1.3. , 4.2.4. , 9.4.4. , 9.4.4.2. , 9.15.1.1.
- drainage, 5.8.1. , 9.14.
- dynamic loading, 4.2.4.7.
- earthquake design, 4.1.8.16. , 4.1.8.17.
- eccentric loading, 4.2.4.6.
- equivalent approaches to design, 4.1.1.5.
- excavations, 4.2.5. , 9.12.
- extension above ground, 9.15.4.6.
- filled ground (on), 4.2.4.13.
- of flat insulating concrete forms, 5.9.1.1. , 9.15.1.1. , 9.15.3.3. , 9.15.4. , 9.15.4.5.
- footing size, 9.15.3.
- frost action, 4.2.4.4. , 9.12.2.2.
- frost jacking, 4.2.4.4.
- frozen ground (on), 9.12.1.3.
- garages and carports, 9.35.3.
- granular drainage layer, 5.8.2. , 9.14.4.
- and groundwater level, 4.2.4.9. , 9.4.4.3.
- for housing and small buildings, 9.15.
- hydrostatic pressure, 4.2.4.8. , 5.8.1.1. , 5.8.2.2. , 9.13.3.1. , 9.16.3.2.
- insulating concrete forms, 9.15.4.1. , 9.15.4.3. , 9.15.4.5.
- insulation, 9.25.2.3.
- lateral support, 9.12.3.4. , 9.15.4.2.
- limit states design, 4.1.3. , 4.2.4.4.
- loads, 4.2.4.
- masonry, 4.2.3.3. , 4.2.3.4.
- materials, 4.2.3. , 9.15.2.
- movement, 4.2.4.1. , 4.2.4.11. , 9.4.4.4. , 9.12.2.2.
- organic soils (on), 4.4.5.1. , 9.12.1.1.
- permafrost (on), 4.2.4.10. , 9.15.1.2.
- pier type, 9.15.2.3.
- protection from freezing, 9.12.1.3.
- protection from surface water, 5.7.1.1.
- review, 4.2.2.2.
- rock (on), 9.4.4.2. , 9.15.3.1. , 9.15.3.2.
- shallow, 1.4.1.2. [A], 4.2.6.
- site stability, 4.1.8.17.
- sloping ground (on), 4.2.4.5.
- special, 4.2.8.
- stairs, 9.12.2.2.
- steel, 4.2.3.6. – 4.2.3.8.
- structural design, 4.2.4.14.
- subsurface investigation, 4.2.4.2.
- swelling and shrinking soils (on), 4.2.4.11. , 9.4.4.4. , 9.35.3.2.
- thickness, 9.15.4.2. , 9.15.4.7.
- trenches beneath, 9.12.4.
- vertical reinforcement, 9.15.4.5.
- walls, 9.4.4.6. , 9.15.4.
- wood, 4.2.3.1. , 4.2.3.2.
- wood-frame construction, 9.15.2.4
- Foundation units definition, 1.4.1.2. [A]
Framing
- anchorage, 9.23.6.
- ceiling, 9.23.14.
- drilling, 9.23.5.1.
- log, 9.38.
- maximum spans, 9.23.4.
- notching and drilling, 9.23.5.
- over openings, 9.23.12.
- plank frame wall construction, 9.3.2.1.
- post, beam and plank construction, 9.3.2.1.
- roof, 9.23.14.
- sheet steel stud, 9.24.
- supported on masonry or concrete, 9.20.8.
- trusses, 9.23.14.11.
- wood-frame, 9.23.
- Freezers, walk-in, 3.1.4.2. , 3.1.5.7. , 9.10.17.10.
Freezing
Freezing, protection from
- concrete, 9.3.1.9.
- excavations, 9.12.1.3.
- fire protection systems, 3.2.5.17. , 9.10.20.5. , 9.10.21.9.
- foundations, 9.12.1.3.
- gypsum board, 9.29.5.10.
- heating, ventilating and air-conditioning systems equipment, 6.2.1.6.
- hose stations, 9.10.21.9.
- masonry, 9.20.14.1.
- piping, 7.3.5.4.
- stairs, 9.8.10.3.
- stucco, 9.28.6.1.
- Fresh air inlets, 1.4.1.2. [A], 7.5.1.1. , 7.5.5.4. , 7.5.6.5.
- Frost penetration, depth, 4.2.4.4. , 9.12.2.2.
- Fuel supply shut-off, 3.2.7.7.
Furnaces, 1.4.1.2.[A], 12.3.1.5.
Furring
G
Gable roofs
- Galvanized sheet metal, 9.3.3.2.
Gambrel roof
- fire blocks, 9.10.16.1.
- venting, 9.19.1.4.
- Galvanized steel or iron pipe and fittings, 7.2.6.7. , 7.3.3.3. , 7.3.4.5.
- Gaming premises, 1.4.1.2. [A], 3.3.1.13. , 3.4.6.16. , 3.18.1.1.
Garages, 3.3.5.4. – 3.3.5.7. , 9.35.
- carbon monoxide detectors (for), 6.3.1.3. , 6.9.3.1. , 9.32.3.9.
- clear height, 3.3.5.4. , 9.5.3.3. , 9.9.3.4.
- columns, 9.35.4.2. , 9.35.4.3.
- detached, 9.10.11.4. , 9.10.14.5. , 9.10.15.5. , 9.35.3.3.
- doors, 9.10.13.15.
- dwelling units (for), 9.10.9.18. , 9.35.
- exhaust discharge into, 6.3.2.10.
- floor loads, 4.1.5.3.
- foundations, 9.35.3.
- guards and guardrails, 9.8.8.4.
- interconnection of duct systems, 9.33.6.11.
- lighting, 9.34.2.6.
- loads on floor or roof, 4.1.5.3.
- open air, 3.2.3.10.
- repair, 3.3.5.4. , 9.10.9.19.
- resistance to forced entry, 9.7.5.2.
- separation, 3.3.5.5. , 3.3.5.6. , 9.10.9.18. , 9.10.9.19.
- storage, 3.3.5.4. , 9.10.4.3. , 9.10.9.18. , 9.32.1.1.
- ventilation, 3.3.5.4. , 6.3.1.3. , 9.32.1.1.
- walls, 9.35.4.1. , 9.35.4.3.
- Garbage grinders, 7.4.3.3. , 8.1.3.1.
- Gas-burning equipment, installation standard, 6.2.1.5.
- Gases, hazardous, 6.9.1.2.
- Gases, hazardous, 3.3.1.2. , 3.3.6.3. , 6.9.1.2.
Gas vents
- definition, 1.4.1.2. [A]
- materials and installation, 9.33.10.1.
- sealing around, 9.25.3.3.
- Girders, in heavy timber construction, 3.1.4.7.
Glass (see also Transparent panels)
- area limit, maximum, 3.1.8.17. , 3.1.8.18. , 9.6.1.3.
- area limit, minimum, 3.7.2.1. , 9.7.2.3.
- design, 4.3.6.1. , 9.6.1.3.
- doors, 3.3.1.20. , 9.6.1.4. , 9.7.5.1.
- doors and sidelights, 3.3.1.20. , 9.6.1.4.
- earthquake design, 4.1.8.18.
- exit enclosures, 3.4.1.8.
- fire separations, 3.1.8.16. – 3.1.8.20. , 9.10.13.5. , 9.10.13.7.
- guards, 9.8.8.7. , 3.1.20.1.
- panels, 3.3.1.20.
- public areas, 9.6.1.4.
- safety, 3.3.1.20. , 3.7.4.10. , 9.6.1.4. , 9.8.8.7.
- sidelights, 9.6.1.4.
- spandrel, 5.9.1.1.
- standards for, 3.3.1.20. , 9.6.1.2. , 9.6.1.4.
- structural design basis, 4.3.6.
- structural sufficiency, 9.6.1.3.
- thermal breaks, 5.3.1.2. , 5.10.2.4. , 9.7.3.3.
- thickness, 9.6.1.3.
- types of, 9.6.1.4
- wired, 3.1.8.16. , 3.2.3.5. , 3.2.3.12. , 3.3.1.20. , 9.9.4.3. – 9.9.4.6. , 9.10.13.5. , 9.10.14.4. , 9.10.15.4.
Glass block, 3.1.8.5. , 3.1.8.16. , 3.1.8.17. , 3.1.8.18. , 3.2.3.5. , 3.2.3.12. , 9.9.4.3. – 9.9.4.6. , 9.10.13.7. , 9.10.14.4. , 9.10.15.4.
- Glass-reinforced polyester roofing, 9.26.14.1.
- Glazed architectural structures (see Fenestration)
- Glazed openings, 9.10.15. , 9.10.15.2. , 9.10.15.4.
Glazing
Glued-laminated timber
- beams, 9.23.4.2.
- flooring, 3.1.4.7.
- lintels, 9.23.12.3.
Grab bars, 3.7.4.13. , 3.8.3.8. , 3.8.3.12. , 3.8.3.13. , 9.31.2.3.
- Grade, 1.4.1.2. [A], 3.2.3.2 , 3.2.3.19. , 3.2.5.1. , 9.10.14.2. , 9.10.15.2.
Grading, site
Granular material
- Grease duct enclosures, 3.6.3.5.
- Grease interceptors (see Interceptors)
- Groove and shoulder mechanical pipe couplings, 7.2.10.4. , 7.3.2.6.
Ground cover
- Groundwater (see also Groundwater level), 1.4.1.2. [A]
- Groundwater level, 1.4.1.2. [A], 4.2.4.9. , 9.4.4.3. , 9.14.5.3. , 9.16.3.2.
- Group A occupancy (see Assembly occupancy)
- Group B occupancy (see Care or Detention occupancy)
- Group C occupancy (see Residential occupancy)
- Group D occupancy (see Business and personal services occupancy)
- Group E occupancy (see Mercantile occupancy)
- Group F occupancy (see Industrial occupancy)
Guarding
Guards,
- balconies, 3.3.1.18. , 3.3.2.8. , 3.3.4.8. , 9.8.8.1. , 9.8.8.2. , 9.8.8.3. , 9.8.8.5.
- balconies in residential occupancy, 9.8.8.1. , 9.8.8.2. , 9.8.8.3. , 9.8.8.5. , 9.8.8.6.
- definition, 1.4.1.2. [A]
- doorways, 9.8.8.1.
- dwelling units, 3.3.4.7. , 9.8.8.
- exits, 3.4.6.6.
- fire escapes, 3.4.7.6.
- fixed seats, 3.3.2.9.
- garages, 3.3.5.4. , 9.8.8.4.
- glass, 3.1.21.1. , 9.8.8.7.
- height, 3.3.1.18. , 3.3.2.9. , 3.3.5.4. , 3.4.6.6. , 9.8.8.3.
- housing and small buildings, 9.8.8.
- industrial occupancies, 3.3.5.10.
- landings, 3.4.6.6. , 9.8.8.3.
- loads, 4.1.5.14. – 4.1.5.15. , 9.8.8.2.
- means of egress, 9.9.1.1.
- to not facilitate climbing, 9.8.8.6.
- openable windows, 3.3.4.8.
- openings through, 3.3.1.18. , 3.4.6.6. , 3.4.7.6. , 9.8.8.5.
- porches, 9.8.8.1. , 9.8.8.2. , 9.8.8.3. , 9.8.8.5.
- as protection for vehicles, 4.1.5.15.
- ramps, 3.4.6.6. , 3.8.3.4. , 9.8.8.1. , 9.8.8.2. , 9.8.8. ,3., 9.8.8.4. , 9.8.8.5.
- secondary suites, 9.8.1.2.
- retaining walls (over), 4.4.3.1.
- stairs, 3.3.1.18. , 3.4.6.6. , 9.8.8.1. , 9.8.8.2. , 9.8.8.3. , 9.8.8.5.
- where required, 3.3.1.18. , 9.8.8.1.
- windows in exits, 3.4.6.6.
- windows in public areas, 3.3.1.20.
- windows in residential occupancy, 3.3.4.8. , 9.8.8.1.
- Gutters, roof, 7.4.10.10.
Gypsum board, 3.1.5.13. , 3.1.5.14. , 3.1.11.7. , 3.1.14.2. , 3.2.3.16. , 3.2.5.14.
- application, 9.29.5.1.
- on exposing building face, 3.2.3.7.
- fasteners, 9.29.5.5. – 9.29.5.7.
- fastening, 9.29.5.8. , 9.29.5.9.
- as firestop, 3.1.11.7.
- installation, 9.29.5.3. – 9.29.5.5. , 9.29.5.8. , 9.29.5.9.
- interior finish, 9.29.5.
- material standard, 9.29.5.2.
- in noncombustible construction, 3.1.5.13.
- standards, 9.10.9.2.
- thermal barrier, 3.1.5.14.
- wall sheathing, 9.23.16.2. , 9.23.17.3.
- Gypsum lath, 9.29.4.1.
- Gypsum panel, 5.9.1.1.
H
- Hallways, width within dwelling units, 9.5.4.1.
Handrails, 9.8.7.
- in aisles with steps, 3.3.2.10.
- attachment, 9.8.7.7.
- continuity, 3.4.6.5. , 9.8.7.2.
- design, 9.8.7.7.
- dwelling unit, 3.3.4.7. , 9.8.7.1.
- ergonomic design, 9.8.7.5.
- graspability, 3.4.6.5. , 9.8.7.5.
- height, 9.8.7.4.
- in housing and small buildings, 9.8.7.
- loads, 3.4.6.5. , 4.1.5.14. , 9.8.7.7.
- long term care homes (in), 3.3.3.8.
- means of egress (in), 9.9.1.1.
- projection, 9.8.7.6.
- projecting into means of egress, 3.4.3.3.
- projecting into stair or ramp, 9.8.7.6.
- ramps, 3.4.6.5. , 3.8.3.4. , 9.8.7.1.
- stairs, 3.4.6.4. , 9.8.7.
- termination, 3.4.6.5. , 9.8.7.3.
- Hangers, pipe, 7.3.4.3. , 7.3.4.5. , 7.3.4.6.
Hardboard, 9.29.7.
- as cladding, 9.27.2.4. , 9.27.3.6. , 9.27.5.
- fastening, 9.29.7.3.
- installation, 9.29.7.3. , 9.29.7.4.
- as insulating finish, 9.25.5.1.
- interior finish, 9.29.7.
- material standards, 5.10.1.1. , 9.29.7.1. , 9.30.2.2.
- nailing, 9.29.7.3.
- siding, 9.27.9.
- thickness, 9.3.2.7. , 9.27.9.2.
- underlay, 9.30.2.2.
- as wall sheathing, 9.25.5.1.
Hardware for doors, (see also doors), 3.1.8.5. , 3.1.8.13. – 3.1.8.15. , 3.4.6.16. , 3.8.3.8. , 3.8.3.12. , 9.9.6.7. , 9.9.6.8.
- access to exit, 3.3.1.13.
- automatic locking devices, 3.3.4.5.
- bolts, 9.7.5.2.
- closers in barrier-free path of travel, 3.8.3.3.
- closers, 3.8.3.3.
- door viewers, 3.8.2.4. , 9.7.2.1.
- door release devices, 3.3.1.13. , 3.3.2.7. , 3.4.6.16. , 9.9.6.7.
- height, 3.4.6.16.
- hinges, 9.7.5.2.
- hold-open devices, 3.1.8.14. 9.10.13.11.
- locks and latches, 3.1.8.15. , 3.4.6.16. , 9.7.5.2. , 9.9.6.8. , 9.10.13.9.
- power operators, 3.8.3.3.
- resist forced entry, 3.3.4.10. , 9.7.5.2.
- self-closing devices, 3.1.8.13. , 3.3.1.9. , 3.3.3.2. , 3.3.4.2. , 3.3.5.7. , 3.4.6.13. , 9.10.13.10. , 9.10.13.15.
- strikeplates, 9.7.5.2.
- on transparent doors and panels, 3.3.1.20.
- universal washrooms, 3.8.3.12.
- Hazard Index, 1.4.1.2. [A], Table 11.2.1.1.-B . to Table 11.2.1.1.-N
- Hatchways, 9.19.2.1. , 9.25.3.3.
Hazardous substances, 3.2.4.10. , 3.3.1.2. , 3.3.1.21. , 3.3.5.3. , 9.10.1.3. , 9.10.18.4.
- Headers, 1.4.1.2. [A], 7.5.7.2.
Headroom clearance
- Healthcare facilities, 7.2.10.6. , 7.2.10.7. , 7.4.7.4. , 7.7.1.1.
Hearths, fireplace, 9.22.5.
- Heat detectors (see also Fire detectors, Smoke detectors), 1.4.1.2. [A], 3.2.4.11. , 9.10.18.4.
Heating appliances
- Heating coils, service water heaters, 9.31.6.5.
Heating systems and equipment
- access, 6.2.1.6. , 6.8.1.1. , 9.33.4.4.
- asbestos in, 6.2.1.7. , 9.33.4.8.
- capacity, 9.33.5.1.
- cleaning, 6.2.1.6. , 9.33.4.4.
- design, 6.2.1.1. , 6.4.1.2. , 9.33.1.1. , 9.33.4.1. , 9.33.5.3.
- earthquake design, 4.1.8.18.
- fire safety characteristics, 6.9.1.1. , 9.33.6.2. – 9.33.6.4.
- installation, 6.2.1. , 9.33.1.1. , 9.33.4.1.
- installation standards, 6.2.1.1. , 6.2.1.5. , 9.33.4.1. , 9.33.5.2. , 9.33.5.3.
- location, 6.4.1.1.
- protection from freezing, 6.2.1.6. , 9.33.4.5.
- in residential buildings, 9.33.2.1.
- solid-fuel-burning, 6.2.1.5. , 9.33.5.3.
- structural movement, 6.2.1.4. , 9.33.4.7.
- system pressure, 6.2.1.3. , 9.33.4.6.
Heat recovery ventilators, 9.32.3.12.
- balancing, 9.32.3.12.
- capacity, 9.32.3.10.
- condensate, 9.32.3.12.
- installation, 9.32.3.12.
- standards for, 9.32.3.10.
Heat transfer
- application of Code, 5.1.1.1.
- calculations and analyses, 5.2.1.3.
- exterior insulation finish systems, 5.9.4.1.
- performance in doors, windows and skylights, 5.9.2.4. , 9.7.3.2.
- performance in other fenestration assemblies, 5.9.3.3.
- and required thermal insulation, 9.25.2.1.
- thermal resistance of assemblies, 5.3.1. , 5.3.1.2.
- Heating coils service water heaters, 9.31.6.5.
Heating, ventilating and air-conditioning (HVAC) systems
- and equipment, Part 6, 9.32.3. , 9.33.
- access, 6.2.1.6. , 6.8.1.1. , 6.2.3.3.
- air duct systems, 6.3.2.
- application of Code, Part 6
- asbestos in, 6.2.1.7.
- capacity, 9.32.3.10. , 9.33.5.1.
- cleaning, 6.2.1.6.
- contaminant transfer prevention, 9.33.4.9.
- design, 6.2.1.1. , 6.4.1.2. , , 9.32.3.2. , 9.33.1.1.
- earthquake design, 4.1.8.18.
- fire safety characteristics, 6.9.1.1. , 9.33.6.2. – 9.33.6.4.
- installation, 6.2. , 9.33.1.1.
- installation standards, 6.2.1.5.
- location, 6.4.1.1.
- outdoor design conditions, 6.2.1.2.
- protection from freezing, 6.2.1.6.
- residential buildings (in), 9.33.2.1.
- solid-fuel burning, 6.2.1.5. , 9.33.5.3.
- structural movement, accommodation of, 6.2.1.4. , 9.33.4.7.
- system pressure, 6.2.1.3.
Heavy timber construction, 1.4.1.2. [A], 3.1.4.6. , 3.1.4.7. , 3.2.2.16. , 3.2.2.21. , 3.2.2.30. , 3.2.2.31. , 3.2.2.35. , 3.2.2.73. , 3.2.2.89. , 3.2.2.90. , 3.2.3.9. , 9.10.6.2.
- construction of exposing building faces, 9.10.14.5. , 9.10.15.5.
- dimensions, 3.1.4.6.
- exposing building faces, 9.10.14.5.
- fire-resistance, 9.10.6.2.
- fire safety requirements, 3.1.4.7.
- flame-spread rating, 3.1.13.8.
- high-hazard industrial occupancy (Group F, Division 1), 3.2.2.82.
- low-hazard industrial occupancy (Group F, Division 3), 3.2.2.89. , 3.2.2.90.
- roofs, 3.2.2.16.
- structural members, 3.2.3.9.
- walkways, 3.2.3.19.
- when permissible, 3.1.4.6. , 3.2.2.16.
Height
- access to exit, 3.3.1.8. , 9.9.3.4.
- between landings, 3.4.6.3. , 9.8.3.3.
- ceilings, 9.5.3.
- doors, 3.4.3.5. , 9.9.6.2.
- doorways, 9.5.5. , 9.9.6.2.
- exits, 3.4.3.4. , 9.9.3.4. , 9.9.6.2.
- guards, 3.3.1.18. , 3.3.2.9. , 3.4.6.6. , 9.8.8.3.
- handrails, 3.4.6.5. , 9.8.7.4.
- landings (over), 9.8.6.4.
- mezzanines, 9.5.3.2.
- over ramps, 9.8.5.3.
- rooms and spaces, 9.5.3.1.
- sleeping areas, 3.7.1.3.
- stairs (over), 3.4.3.4. , 3.4.7.5. , 9.8.2.2.
- storage garages, 3.3.5.4. , 9.5.3.3. , 9.9.3.4.
- Helicopter landing areas 3.2.4.7. , 3.2.4.16. , 4.1.5.13.
High hazard industrial occupancy (Group F, Division 1), 1.4.1.2. [A], 3.2.4.3. , 3.3.1.5.
- High importance buildings, 4.1.8.1. , 4.1.8.5. , 4.1.8.10. , 4.1.8.13. , 4.1.8.23.
- Hipped roofs, wind loads, 4.1.7.6.
- Hold-open devices, see hardware for doors.
Horizontal exits, 1.4.1.2. [A], 3.3.3.5. , 3.4.1.4. , 3.4.1.6.
- Horizontal offsets (see offsets in piping) 2.4.2.1. , 7.4.9.5. , 7.4.10.6. , 7.5.2.1. , 7.5.4.4.
- Horizontal piping, support of, 7.3.4.5. , 7.3.4.6.
Horizontal service spaces, 1.4.1.2. [A], 3.2.5.14. , 3.6.1.1. , 3.6.4.
- access, 3.6.4.5.
- fire blocks in, 3.1.11.5.
- fire separations (above), 3.1.8.3. , 9.10.9.12. , 9.10.9.12.
- fire separations for, 3.6.4.2.
- sprinkler systems, 3.2.5.13.
- Hose bibb, 7.6.2.7. , 7.6.3.2.
- Hose cabinets, 3.2.5.11.
- Hose connections, 3.2.5.15. , 3.2.5.10.
- Hose stations, 3.2.5.11.
- Hospitals, 3.1.8.13. , 3.2.7.6. , 3.3.3.3. , 3.3.3.5. , 3.4.1.6. , 3.7.4.2.
- Hot water supply, 9.31.4.2. , 9.31.6.1.
- Hot water systems, 7.2.5.7. , 7.2.5.12. , 7.2.10.7. , 7.2.10.13. , 7.4.4.2. , 7.6.1.1. , 7.6.1.8. , 9.31.4.2.
- Hot water temperature, 7.6.5.1. , 9.31.6.1A.
- Hot water waste, cooling of, 7.4.4.2.
Hotel, 1.4.1.2. [A], 3.1.8.13. , 3.11.2.1. , 9.10.13.10. , 9.11.1.1.
Housing and small buildings (see also Dwelling units)
- air leakage, 9.25.
- cladding, 9.27.
- columns, 9.17.
- concrete materials, 9.3.1.
- condensation control, 9.25.
- crawl spaces, 9.18.
- dampproofing, 9.13.
- design of areas and spaces, 9.5.
- drainage, 9.14.
- electrical facilities, 9.34.
- excavations, 9.12.
- fire protection, 9.10.
- fireplaces, 9.22.
- flooring, 9.30.
- floors-on-ground, 9.16.
- footings and foundations, 9.15.
- glass, 9.6.
- heat transfer, 9.25.
- heating and air-conditioning, 9.33.
- interior wall and ceiling finishes, 9.29.
- lumber and wood products for, 9.3.2.
- masonry and concrete chimneys, 9.21.
- masonry and insulating concrete walls, 9.20.
- materials, systems and equipment, 9.3.
- means of egress, 9.9.
- plumbing facilities, 9.31.
- roof spaces, 9.19.
- roofing, 9.26.
- sheet steel stud wall framing, 9.24.
- soil gas control, 9.13.
- sound control, 9.11.
- stairs, ramps, handrails and guards, 9.8.
- structural requirements, 9.4.
- stucco, 9.28.
- ventilation, 9.32.
- waterproofing, 9.13.
- windows, doors and skylights, 9.7.
- wood-frame construction, 9.23.
- Hub and spigot pipe, 7.3.2.1.(4)
- HVAC (see Heating, ventilating and air-conditioning systems and equipment)
- Hydrant, 3.2.5.5. , 3.2.5.7. , 3.10.3.4. , 3.10.4.5. , 9.10.20.3.
- Hydrant, frost proof, 7.6.1.9.
Hydraulic loads,
- Hydromassage bathtubs, 7.2.2.2.
Hydronic heating
- Hydrostatic pressure, 4.2.4.8. , 5.8.1.1. , 9.1.1.8. , 9.13.1.1. , 9.13.3.1. , 9.16.3.2.
I
- Iceboxes, 7.4.9.3.
- Ice, accumulation, 5.6.2.2. , 9.26.1.1.
Identification
Impeded egress zones,
- Importance categories for buildings, 4.1.2.1.
Importance factors
- Incinerator rooms, 3.6.2.4. , 9.10.10.5.
- Incinerators, design, 6.2.2.1.
- Increaser fittings, 7.3.3.5.
- Independence of support, 7.3.4.2.
- Indirect connections, 7.3.3.11. , 7.4.2.1. , 7.4.3.2. , 7.4.4.4. , 7.7.2.4.
- Indirectly connected, 1.4.1.2. [A], 7.3.3.11. , 7.4.2.1. , 7.4.5.1. , 7.4.5.5.
- Indirect service water heater (see Service water heater, indirect)
- Indirect service water heaters, 1.4.1.2. [A], 7.6.1.7. , 7.6.1.12.
- Individual vents, 1.4.1.2. [A], 7.5.1.1. , 7.5.8.2. , 7.5.9.1.
- Indoor design temperature, 5.2.1.2. , 5.3.1.2. , 5.5.1.2. , 9.33.3.1.
- Industrial occupancy (Group F) (see also High-hazard industrial occupancy, Low-hazard industrial occupancy, Medium-hazard industrial occupancy), 1.4.1.2. [A]
- building construction, 9.10.8.
- classification, 3.1.2.1. , 9.10.2.
- door thresholds, rooms with flammable liquids, 3.3.1.13. , 3.4.6.1.
- exposing building face, 9.10.14.5.
- fire alarms systems, 9.10.18.
- fire separations, 9.10.9.13. , 9.10.9.14
- flame-spread rating, 9.10.17.
- guards, 3.3.5.10. , 9.8.8.5.
- ramps and stairways, 3.3.1.14. , 3.4.6.7. , 3.4.6.8.
- self-service storage buildings, 3.9.1.3.
- standpipe and hose systems, 9.10.1.3.
- washrooms, 3.7.2.
- Inlets, fresh air, 7.5.1.1. , 7.5.5.4.
- Inspection (see Testing)
Installation of fixtures, 7.1.6.1. ,
- Institutional occupancy (see Care or detention occupancy)
- Insulating concrete forms, 9.3.1.1. , 9.13.2.3. , 9.15.1.1. , 9.15.3.3. , 9.15.3.5. , 9.15.4.1. – 9.15.4.5. , 9.20.1.1. , 9.20.17.
Insulation,
- attic or roof spaces, 9.25.2.4.
- basements, 9.25.2.2.
- combustible, 3.1.5.14.
- concealed spaces, 3.1.11.2.
- crawl spaces, 9.18.1.3.
- ducts, 3.1.5.18. , 6.3.2.6A. , 9.33.6.6.
- environmental separation, 5.1.1.1.
- exposure to exterior space on ground, 5.1.2.1.
- foamed plastic, 3.1.4.2. , 3.1.5.14. , 3.1.5.15. , 3.2.3.8. , 9.10.17.10.
- foundations, 9.12.2.2. , 9.25.2.2. , 9.25.2.3.
- installation, 5.3.1.3. , 9.25.2.3. – 9.25.2.5.
- loose-fill, 9.25.2.4.
- material standards, 5.10.1.1. , 9.25.2.2.
- noncombustible construction, 3.1.5.12. , 3.1.5.15.
- pipes, 3.1.5.18. , 6.5.1.1.
- plenums, 9.33.6.4.
- properties, 9.25.5.1.
- protection, 3.1.5.14. , 9.10.17.10. , 9.25.2.3.
- requirement for, 5.3.1.1. , 9.25.2.1.
- slabs-on-ground, 9.25.2.3.
- spray-applied, 5.3.1.3.
- supported by gypsum board, 9.29.5.4.
- thermal, 9.25.2.
- thermal resistance, 5.3.1.
- walls, 9.25.2.4.
- wall sheathing, 9.23.17.2. , 9.23.17.3.
- wires and cables, 3.1.5.21.
- Insulation, electrical, 7.3.4.3.
Interceptors
- capacity of, 7.4.4.3.(8)
- cleanouts for, 7.4.7.1.(8)
- definition, 1.4.1.2. [A]
- design of, 7.2.3.2.
- drum traps serving as, 7.2.3.1.
- gasoline, 7.4.4.3.(2)
- grease, 7.2.3.2. , 7.4.4.3.(1)
- location, 7.1.3.2.
- oil, 7.4.4.3.
- replacing traps, 7.4.5.1.
- restricted use of, 7.4.3.3.
- sand or grit, 7.4.4.3.
- venting of, 7.5.5.2.
- where required, 7.4.4.3.
- Interconnected floor space, 1.4.1.2. [A], 3.2.3.2. , 3.2.8. , 9.10.9.5.
- Interconnection of duct systems, 6.3.2.7. , 6.3.2.10. , 9.33.6.7.
Interior finishes, 3.1.13.1. , 3.1.13.2.
- bathrooms in residential suites, 3.1.13.3.
- for braced wall panels, 9.23.13.6.
- ceilings, 9.29.
- combustible, 3.1.5.10.
- dampproofing, 9.13.2.5.
- elevator cars, 3.1.13.11.
- encapsulated mass timber construction, 3.1.13.12.
- exterior exit passageway, 3.1.13.10.
- fastening to steel studs, 9.24.1.4.
- flame spread limits, 3.1.13. , 9.10.17.
- flame-spread rating, 3.1.13.2.
- floors, 9.30.
- food premises, 3.7.6.2.
- gypsum board, 9.29.5.
- hardboard, 9.29.7.
- high buildings, 3.1.13.7.
- insulating fibreboard, 9.29.8.
- light diffusers and lenses, 3.1.13.4.
- masonry walls, 9.20.13.9.
- materials, 3.1.13.1.
- in noncombustible construction, 3.1.5.14. , 3.1.13.8.
- OSB, 9.29.9.
- particle board, 9.29.9.
- plastering, 9.29.4.
- plywood, 9.29.6.
- public corridor ceilings, 3.1.13.6.
- skylights, 3.1.13.5.
- on steel studs, 9.24.1.5.
- support, 9.23.10.5. , 9.24.3.4.
- tile, 9.29.10.
- underground walkways, 3.1.13.9.
- waferboard, 9.29.9.
- walls, 9.29.
- waterproof, 9.29.2.
J
- Janitors’ rooms, 3.2.4.10. , 3.3.1.20. , 9.10.18.4.
- Jointing materials, 7.2.9.
- Joints and connections for ducts, 6.2.3.3. , 9.33.6.2. , 9.33.6.3. , 9.33.6.6. , 9.33.6.7.
- Joints, pipe, 7.3.2. , 7.3.3. , 7.2.1.5. , 7.2.5.2. , 7.2.5.3. , 7.2.6.4. , 7.3.2. , 7.3.3.
Joists, 9.23.9.
- bearing, 9.20.8.3. , 9.23.9.1. , 9.23.13.3.
- cantilevered, 9.23.9.9.
- ceilings, 9.4.2.4. , 9.23.14.1. – 9.23.14.3. , 9.23.14.7. 9.23.14.10.
- continuity, 9.23.14.1.
- dimensions, 9.23.4.1. , 9.23.14.7. , 9.23.14.10.
- end bearing length, 9.23.14.3.
- floors, 9.23.4.1. , 9.23.4.2. , 9.23.4.4. , 9.23.9.
- framing around openings, 9.23.14.2.
- header, 9.23.9.5. , 9.23.9.7.
- lumber grade, 9.3.2.1. , 9.3.2.2.
- nailing, 9.23.3.4. , 9.23.9.3. , 9.23.14.9.
- preservative treatment, 9.23.2.2. , 9.23.2.3.
- roofs, 9.23.4.5. , 9.23.14.1. – 9.23.14.3. , 9.23.14.7. , 9.23.14.9.
- size, 9.23.4.1. , 9.23.13.7. , 9.23.13.10.
- spans, 9.23.4.1. , 9.23.4.4. , 9.23.4.5. , 9.23.14.7. , 9.23.14.10.
- strapping and bridging, 9.23.9.4.
- support, 9.23.9.7. , 9.23.14.7.
- supported on beams, 9.23.9.2.
- supported on masonry or concrete, 9.20.8.2. , 9.20.8.3. , 9.21.5.3. , 9.23.2.2. , 9.23.2.3.
- supported on insulating concrete form walls, 9.20.17.5.
- supporting walls, 9.23.9.8.
- tail, 9.23.9.7.
- trimmer, 9.23.9.6.
- undersized, 9.3.2.8.
- wood, 9.3.2.
- Junction boxes, electrical, 3.1.5.2. , 9.10.9.6.
K
Kitchens
L
Laboratories
Landings
- barrier-free, 3.8.3.4.
- configurations, 9.8.6.3.
- dimensions, 3.4.6.4., 9.8.6.3.
- doorways (at), 3.4.3.3., 3.4.6.3., 9.8.6.2., 9.8.6.3., 9.9.6.1.
- fire escapes, 3.4.7.7.
- guards, 9.8.8.1.
- height between, 3.4.6.3., 9.8.3.3., 9.8.4.4., 9.8.5.5.
- height over, 3.4.6.4.
- in housing and small buildings, 9.8.6.
- omitted, 3.4.6.3.
- openings in, 3.4.6.4.
- as part of exit, 9.8.1.3.
- on ramps, 3.4.6.3., 3.8.3.4., 9.8.6.3.
- slip-resistance, 3.4.6.1., 9.8.9.6.
- on stairs, 3.4.6.3., 9.8.6.2.
Lath, stucco,
- Lattice structures, ice loading, 4.1.6.15
- Laundry facilities in dwelling units, 9.31.4.1A.
- Laundry-drying equipment, 9.32.1.3.
- Laundry rooms, 3.2.4.10. , 3.3.1.22. 9.10.18.4.
- Laundry trays, 7.2.3.1. , 7.4.5.1. , 7.4.9.3. , 7.7.2.2.
- Lavatories, 7.2.3.1. , 7.2.10.6. , 7.4.9.3. , 7.6.3.2. , 3.7.4.2. – 3.7.4.5. , 3.7.4.15 , 3.7.6.4. , 3.8.3.11 , 3.8.3.12. , 3.10.2.7. , 3.11.9.1. , 3.13.6.2.
Lead
- Lead content of solders and fluxes, 7.2.9.2.
Leaders (or downspouts)
- Lead waste pipe and fittings, 7.2.7.8. , 7.3.4.5.
- Lead water-closet bends, 7.2.7.8. , 7.4.2.1.
- Lead water-closet stubs, 7.3.3.8.
- Libraries, 3.3.2.11. , 4.1.5.3.
Licensed beverage establishments
- Life safety systems, 3.2.9.1. , 9.10.1.2.
- Light diffusers and lenses, 3.1.13.4. , 9.10.17.6. , 9.10.17.8.
Lighting
- basements, 9.34.2.3. , 9.34.2.4.
- elements, 3.1.13.1. , 9.10.17.6. , 9.10.17.8.
- entrances, 9.34.2.1
- emergency, 3.2.7.3. , 3.2.7.4. , 9.9.12.3. , 9.34.3.
- exits, 3.2.7.1. , 9.9.12.
- exterior, 9.34.2.1.
- fixtures, recessed, 3.2.7.2. , 9.34.1.4.
- garages and carports, 9.34.2.6.
- levels, 3.2.7.1. , 9.9.12.2. , 9.9.12.3. , 9.34.2.7.
- levels, minimum, 3.2.7.1
- means of egress, 9.9.12.
- natural, 3.7.2.1. , 9.7.2.3.
- outlets for, 3.2.7.1. , 9.34.2.
- public corridors, 3.2.7.1. , 9.9.12.2. , 9.9.12.3.
- public and service areas, 9.34.2.7.
- rooms, 7.1.6.1.(1) , 9.34.2.2.
- public and service areas, 9.34.2.7.
- stairways, 9.34.2.3.
- Lighting of rooms, 7.1.3.1.
- Limited-use/limited-application elevators, 3.5.4.1.
- Limiting distance, 3.1.7.2. , 3.2.3.1. , 3.2.3.5. , 3.2.3.7. , 3.2.3.10. , 3.2.3.11. , 3.2.3.14. , 9.10.14. , 9.10.15.
Limiting distance
- between construction camp buildings, 9.10.21.5.
- definition, 1.4.1.2. [A]
- exposing building face, 3.2.3.5. , 3.2.3.6. , 3.2.3.7. , 9.10.14.5. , 9.10.15.5.
- exterior walls, 9.10.3.3.
- fire department response time, 3.2.3.1.
- fire-resistance rating exception, 3.1.7.2.
- less than 1.2 m, 3.2.3.5.
- low-hazard industrial occupancy (Group F, Division 3), 3.2.3.11.
- maximum concentrated area, 3.2.3.1.
- spatial separation between buildings, 3.2.3.1. , 9.10.15.
- unprotected openings, 3.2.3.1. , 3.2.3.10.
- wall exposed to another wall, 3.2.3.14.
Limit states design, 4.1.3.
- Linen chutes, 3.6.3.3. , 9.10.1.3.
Liners, chimney, 9.21.3.
Liners, fireplace, 9.22.2.
Lining
Lintels
- dimensions, 9.23.12.3.
- fireplaces, 9.22.1.2.
- insulating concrete form walls (for), 9.20.17.4.
- nailing, 9.23.12.3.
- size, 9.23.12.3.
- spans, 9.23.12.3.
- steel, 3.2.2.3. , 9.10.7.1. , 9.20.5.2.
- supporting masonry over openings, 9.20.5.2.
- wood, 9.23.12.
- Liquids, combustible (see Combustible liquids)
- Liquids, flammable (see Flammable liquids)
- Liquids, hazardous, 3.3.6.4. , 6.9.1.2.
- Loadbearing, 1.4.1.2. [A]
- Live loads (see Loads)
Loads
- attics (in), 9.4.2.4.
- bearing pressure for soil or rock, 9.4.4.1.
- climatic, 5.2.1.1.
- combinations, 4.1.3.2.
- concentrated, 4.1.5.9.
- crane, 4.1.2.1. , 4.1.5.11.
- dead, 4.1.4. , 9.4.3.1.
- deflections under, 4.1.3.5. , 9.4.3.
- design requirement, 4.1.1.3.
- dining areas, 4.1.5.6
- drainage, 5.8.1.2.
- due to crane, 4.1.3.2. , 4.1.5.11.
- due to earthquakes, 4.1.3.2. , 4.1.8.
- due to ice, 4.1.6.15.
- due to partitions, 4.1.4.1.
- due to resonance, 4.1.3.6.
- due to snow and rain, 4.1.6. , 4.1.6.4. , 9.4.2.2. , 9.4.2.3.
- due to sway forces, 4.1.5.10.
- due to use and occupancy, 4.1.5.
- during construction, 4.1.1.3.
- earthquake, 4.1.8.
- eccentric, on foundations, 4.2.4.6.
- environmental, 5.1.4.1. , 5.2.1. , 5.2.2.1.
- environmental, calculation, 5.2.2.1.
- exterior areas (on), 4.1.5.5.
- firewalls (on), 4.1.5.17.
- floors (on), 9.23.1.1. , 9.23.4.1.
- foundations (on), 9.4.4.
- footings, 9.4.4.1.
- full and partial, 4.1.5.3.
- grab bars (on), 3.7.4.14. , 3.8.3.8. , 9.31.2.3.
- guards (on), 4.1.5.14. , 9.8.8.2.
- handrails (on), 3.4.6.5. , 4.1.5.14. , 9.8.7.7.
- hydraulic, 7.4.9.3. , 7.4.10. , 7.5.2.1. , 7.5.3.1. , 7.5.8.1. , 7.5.8.3. , 7.6.3.2. , 7.6.3.4.
- and helipads, 4.1.5.13.
- hydraulic, 7.4.10.
- hydrostatic, 4.2.4.8. , 5.8.1.1. , 5.8.2.2. , 5.8.2.3. , 9.13.3.1. , 9.16.3.2.
- impact of machinery and equipment, 4.1.5.11.
- interior walls and partitions (on), 4.1.7.4.
- limit states, 4.1.3.
- live, 1.4.1.2. [A], 4.1.5.
- with more than one occupancy, 4.1.5.7.
- not specified, 4.1.2.2
- partitions (due to), 4.1.4.1.
- permanent, 4.1.3.2
- rain, 4.1.6.4. , 9.4.2.2.
- on ramps, 9.8.9.1.
- residential balconies (on), 4.1.5.3. , 9.4.2.3.
- resonance (due to), 4.1.3.6.
- retaining walls (on), 9.4.4.6.
- snow, 4.1.6. , 9.4.2.2. , 9.4.2.3.
- soil bearing pressure, 9.4.4.1. – 9.4.4.3.
- specified, 4.1.2. , 9.4.2.
- stairs (on), 9.8.9.1
- structural, 4.1. , 9.4.
- structural, on environmental separators, 5.1.4.1. , 5.2.2.
- and structural strength, 5.2.2.
- sway forces (due to), 4.1.5.10.
- use and occupancy (due to), 4.1.5.
- variation with tributary area, 4.1.5.8.
- vehicle guardrails, 4.1.5.15.
- vibration, 4.1.3.3. , 4.1.3.6.
- walls acting as guards (on), 4.1.5.16.
- from walls, isolation of piping from, 7.3.5.2.
- wind, 4.1.7. , 5.2.2. , 9.4.1.1. , 9.21.4.5.
- Lobbies, 3.4.4.2. , 9.9.8.5. , 9.10.17.3.
- Location of Fixtures 7.4.2.
Locking devices
- Locks deadbolt, 9.7.5.2.
- Long term care homes, 3.1.8.13. , 3.1.8.14. , 3.1.8.15. , 3.2.4.8. , 3.3.3.5. , 3.3.3.8. , 3.4.1.6. , 3.4.1.11. , 3.4.6.5.
- Low buildings, wind loads, 4.1.7.5. , 4.1.7.6.
- Lowest exit level, 3.2.6.2. , 3.4.3.2. , 3.4.5.3. , 9.9.11.4
- Low fire load, 3.2.2.91. , 3.2.3.11.
Low-hazard industrial occupancy (Group F, Division 3), 1.4.1.2. [A]
- Lowest exit level, 3.2.6.2.
Lumber, 9.3.2.
- dimensions, 9.3.2.6. , 9.3.2.8.
- fire block, 3.1.11.7. , 9.10.12.4. , 9.10.16.3.
- grades, 9.3.2.1. – 9.3.2.3.
- for housing and small buildings, 9.3.2.
- moisture content, 9.3.2.5.
- protection from termites and decay, 9.3.2.9.
- sheathing, 9.23.16.5.
- siding, 9.27.6.
- structural uses, 9.3.2.9.
- undersized, 9.3.2.8.
M
- Main entrances (see Principal entrances)
Machinery rooms
- building height exception, 3.2.1.1. , 9.10.4.4.
- fire separations, 3.2.2.14. , 3.6.2.1. , 9.10.10.2. , 9.10.10.3.
- Macerating toilet systems, 7.2.2.2. , 7.4.3.5. , 7.4.9.2. , 7.4.9.3. , 7.5.7.7.
Major occupancy, 1.4.1.2. [A], 3.2.2.6.
- and building classification, 3.1.2.1. , 9.10.2.
- building area determination, 3.2.2.5.
- classification, 3.1.2.1. , 9.10.2.
- exceptions, 3.2.2.8.
- fire separations, 3.1.3.1.
- exceptions, 3.2.2.8.
- multiple occupancies, 3.1.3. , 3.2.2.4. , 3.2.2.6. , 9.10.2. , 9.10.9.13. , 9.10.9.18. , 9.10.9.19.
- superimposed occupancies, 3.2.2.7.
Make-up air
- and depressurization protection, 9.32.3.8.
- fans, 9.32.3.10.
- requirements, 6.3.2.8.
- for subfloor depressurization, 9.13.4.3.
- venting of laundry-drying, 6.3.2.10.
- Make-up water connections, 6.3.2.15. , 6.3.2.16.
- Malleable iron water fittings screwed, 7.2.6.6.
Manholes, 7.4.7.1.(4) , 7.4.7.2. , 7.4.7.3.
Mansard roof
- fire blocking, 3.1.11.5. , 9.10.16.1.
- sheathing, 9.23.17.6.
- venting, 9.19.1.4.
- Manual stations, fire alarm systems, 3.2.4.4. , 3.2.4.16.
- Manually operated valves, 7.2.10.6.
- Manufactured buildings, foundations, 9.12.2.2. , 9.15.1.3.
- Marking pipes and fittings, 7.2.1.3. , 7.7.2.1.
Marquees, 3.1.5.23. , 3.1.16.1.
- fascia, 3.1.5.25.
Masonry
- bonding, 9.20.9. , 9.20.11.2.
- chases and recesses, 9.20.7.
- chimneys (see Chimneys, masonry), 1.4.1.2. [A], 6.3.3.2. , 9.21. , 9.33.10.3.
- cold weather requirements, 9.20.14.
- columns, 9.17.5.
- corbelling, 9.20.12.
- dampproofing, 9.13.2.3.
- design basis, 4.3.2.1.
- earthquake reinforcement, 9.20.1.2. , 9.20.15.
- exposure to weather, 9.20.2.6.
- flashing, 9.20.13. , 9.26.4.2. – 9.26.4.8.
- flues, 9.21.
- foundations, 4.2.3.3. , 4.2.3.4. , 9.15.2. , 9.15.4. , 9.15.4.10.
- grout, 9.20.3.2.
- installation, 9.15.2.2. , 9.20.
- joints, 9.20.4. , 9.20.9.1.
- lateral support, 9.20.10.
- material standards, 5.10.1.1. , 9.15.2.2. , 9.17.5.1. , 9.20.2.1. , 9.20.2.6.
- mortar, 9.20.3.1. , 9.20.3.2.
- protection of exterior building face, 3.2.3.8.
- parapet walls, 9.20.6.5.
- for pilasters, 9.15.5.3.
- solid, 1.4.1.2. [A]
- structural design basis, 4.3.2.1.
- stucco on, 9.28.1.3.
- supporting beams, 9.15.5.2.
- supporting floor joists, 9.15.5.1.
- support of loads, 9.20.5. , 9.20.8.
- supporting stucco, 9.28.1.3.
- thermal barrier, 3.1.5.12.
- ties, 9.20.9.5.
- tying, 9.20.9. , 9.20.11.2.
- units, 1.4.1.2. [A], 9.20.2. , 9.20.2.1.
- used brick, 9.20.2.2.
- veneer, 9.20.6.4.
- walls, 9.20.
- weep holes, 9.20.13.8.
- Masonry or concrete chimney (see Chimneys, masonry or concrete)
Materials,
- braced wall panels, 9.23.13.6.
- characteristics, 1.2.2. [A]
- cladding, hardboard, factory-finished, 9.27.9.1.
- cladding, lumber, 9.27.6.1.
- cladding, OSB and waferboard, 9.27.10.1.
- cladding, plywood, 9.27.8.1.
- cladding, strip steel, 9.27.11.1.
- cladding, vinyl, 9.27.12.1.
- columns, unit masonry, 9.17.5.1.
- columns, wood, 9.17.4.2.
- combustible, in noncombustible construction, 3.1.5.2. , 9.10.6.1.
- concrete, 9.3.1.
- dampproofing, 9.13.2.2.
- design requirements, 4.3.
- drainage tile and pipe, 9.14.3.1.
- ducts, 6.2.4.2. , 6.3.2.3.
- eave protection, 9.26.5.2.
- exterior insulation finish systems, 9.27.14.
- fibreboard, insulating, 9.29.8.1.
- fire block, 3.1.11.17. , 9.10.16.3.
- fire stop, 3.1.9.1.
- flashing, 9.20.13.1. , 9.26.4.2. , 9.27.3.7.
- foundations, 4.2.3.
- glass, 9.6.1.2.
- granular, beneath floors, 9.16.2.
- gypsum products, 9.29.5.2.
- hardboard, 9.29.7.1.
- for housing and small buildings, 9.30.
- lumber and wood products, 9.3.2.
- metal, 9.3.3.
- particleboard finish, 9.29.9.1.
- pipes for heating and cooling systems, 6.2.9.1. , 9.33.8.1.
- roofing, 9.26.2.1.
- roof sheathing, 9.23.16.2.
- sealants, 9.27.4.2.
- shingles and shakes, 9.27.7.1.
- standards, 5.9.1.1.
- steel studs and runners, 9.24.1.2.
- storage, 9.10.1.3.
- subflooring, 9.23.15.2.
- testing, 4.1.1.5.
- underlay, panel-type, 9.30.2.2.
- waterproofing, 9.13.3.2. , 9.29.2.2.
Materials, appliances, systems and equipment
Materials and equipment
- characteristics, 1.2.2.1. [A]
- corrosion-resistant, 7.2.8. , 7.2.10.2.
- defects, 1.2.2.1. [A]
- dissimilar, 7.3.3.6.
- exposure, 7.2.1.1.
- fixtures, 7.2.2.
- identification, 7.2.1.3. , 7.7.1.2.
- for jointing, 7.2.9.
- minimum pressure, 7.2.1.5.
- miscellaneous, 7.2.10.
- pipe fittings, 7.2.4.
- pipe and fittings, ferrous, 7.2.6.
- pipe and fittings, non-ferrous, 7.2.7.
- pipe and fittings, non-metallic, 7.2.5.
- traps and interceptors, 7.2.3.
- used, 7.2.1.2.
Means of egress (see also Exits)
- from care, treatment or detention occupancy, 3.3.3.3.
- definition, 1.4.1.2. [A]
- dimensions, 3.3.1. , 9.9.3.
- from dwelling units, 3.3.4.4. , 9.9.9.
- exterior passageways as, 3.2.2.12.
- and fire hose cabinets, 3.2.5.11.
- within floor areas, 3.3.1.3.
- from housing and small buildings, 9.9.
- lighting of, 9.9.12.2.
- mezzanine, 3.3.1.3. , 9.9.8.6.
- obstructions, 3.3.1.24. , 3.4.3.3. , 9.9.5. , 9.9.5.5. , 9.9.11.2.
- from outdoor places of assembly, 3.3.2.11.
- from secondary suites, 9.9.9.
- shelf and rack storage systems, 3.16.1.7.
- sliding doors in, 3.3.1.12.
- tents, 3.14.1.3.
- transparent panels or doors in, 3.3.1.20. , 9.6.1.4.
- with two separate exits, 9.9.9.2.
- Measurement, rooms and spaces, 9.5.1.1.
- Mechanical couplings, 7.2.10.4.
- Mechanical damage, protection against, 7.3.5.4.
Mechanical joints, 7.3.2.6.
- Mechanical systems and equipment (see Heating, ventilating and air-conditioning systems and equipment)
- Mechanical ventilation (see Ventilation)
- Medical gas piping, 3.7.5.2.
Medium hazard industrial occupancy (Group F, Division 2), 1.4.1.2. [A]
- Membrane fire protection, openings, 3.1.9.5. , 9.10.5.
Mercantile occupancy (Group E), 1.4.1.2. [A]
- building construction, 9.10.8.
- classification, 3.1.2.1. , 9.10.2.
- exit stairs, 9.9.4.7.
- exposing building face, 9.10.14.5.
- fire alarm systems, 3.2.4.1. , 9.10.18.
- fire protection, 3.2.2.66. – 3.2.2.71. , 3.2.2.93.
- fire-resistance rating, 9.10.8.
- fire safety within floor areas, 3.3.1.
- flame-spread rating, 3.1.13. , 9.10.17.
- occupant load, 3.1.17.1.
Metal, 9.3.3.
- Metal roof deck assembly, 3.1.14.2.
Mezzanines, 1.4.1.2. [A],
- application of requirements to exterior passageways, 3.2.2.12.
- assembly occupancy (Group A, Division 1), 3.2.2.20. – 3.2.2.22.
- assembly occupancy (Group A, Division 2), 3.2.2.23. – 3.2.2.26. , 3.2.2.93.
- assembly occupancy (Group A, Division 3), 3.2.2.29. – 3.2.2.32.
- and building height, 3.2.1.1. , 9.10.4.1. , 9.10.4.2.
- business and personal services occupancy (Group D), 3.2.2.56. - 3.2.2.65. , 3.2.2.93.
- care occupancy (Group B, Division 3), 3.2.2.42. – 3.2.2.46. , 3.2.2.93.
- care and treatment occupancy (Group B, Division 2), 3.2.2.38. – 3.2.2.41.
- detention occupancy (Group B, Division 1), 3.2.2.36. , 3.2.2.37.
- exits, 3.4.2.2. , 9.9.8.6.
- fire-resistance rating, 3.2.2.17. , 9.10.8.6. , 9.10.9.4.
- fire separations, 3.2.8.1. , 3.2.8.2. , 9.10.12.1.
- guards, 9.8.8.1.
- gymnasiums, swimming pools, arenas and rinks, 3.2.2.17.
- height, 9.5.3.2.
- high-hazard industrial occupancy (Group F, Division 1), 3.2.2.72.
- loads on floor or roof, 4.1.5.3. , 4.1.5.4.
- low-hazard industrial occupancy (Group F, Division 3), 3.2.2.82. – 3.2.2.86. , 3.2.2.93.
- means of egress, 3.4.2.2. , 9.9.8.6.
- medium-hazard industrial occupancy (Group F, Division 2), 3.2.2.76. – 3.2.2.79. , 3.2.2.93.
- mercantile occupancy (Group E), 3.2.2.66. – 3.2.2.69. , 3.2.2.93.
- occupant load, 3.1.17.1.
- openings in floor assemblies, 3.2.8.2.
- residential occupancy (Group C), 3.2.2.47. – 3.2.2.55. , 3.2.2.93.
- Retirement home (Group C), 3.2.2.55A - 3.2.2.55E.
- termination, 9.10.12.1.
- Micro-organisms, minimizing growth, 6.3.1.5. 6.3.2.2. , 6.3.2.15. , 6.3.2.16.
- Mild climate indicator, 9.25.4.2. , 9.25.5.1.
- Millwork, combustible, 3.1.5.7.
Mirrors
- Misters, 6.3.2.16.
Mobile homes, 9.39.
- Mobile home parks, sanitary facilities, 3.7.4.10.
Mobile homes, 9.1.1.9.
- foundations, (see Foundations, deformation resistant buildings)
Moisture
Mortar,
- aggregate for, 5.9.1.1. , 9.20.3.1. , 9.20.3.2. , 9.29.10.2.
- as base for ceramic wall tile, 9.29.10.2.
- cement, 7.2.9.1.
- cement jointing for pipes, 7.2.9.1.
- cement lining, 7.2.6.4.
- ceramic wall floor, 9.30.6.
- chimney liner (for), 9.21.3.9.
- cold weather requirements, 9.20.14.
- foundation wall, (parged), 9.13.2.4. , 9.13.3.4.
- joints, 9.20.4.
- material standards, 9.15.2.2. , 9.20.3.1.
- mixes, 9.20.3.2.
- standard for, 9.20.3.
- tying, (for), 9.20.9.4.
- uses, 9.20.3.2.
Mortuaries
- Motion sensors, 12.2.4.1.
Movement, differential, 6.2.1.4.
- Moving walks, 3.2.8.2. , 3.8.1.4. , 9.8.1.4.
Multiple occupancies,
- and building classification, 9.10.2.
- building size and construction requirements, 3.2.2.4.
- fire separations, 3.1.3.
- requirements decided by most restricted occupancy, 3.2.2.6.
- separation of repair garages, 9.10.9.19.
- separation of residential occupancies, 9.10.9.13.
- separation of storage garages, 9.10.9.18.
- separation, (of), 3.1.3.1. , 9.10.9.
- Multi-storey venting, 7.5.4.
N
Nailing
- bracing, 9.23.10.2.
- built-up beams, 9.23.8.3.
- cladding, 9.27.5.4.
- columns, 9.17.4.2.
- fibreboard finish, 9.29.8.3.
- framing, 9.23.3.4.
- furring, 9.29.3.2.
- gypsum board, 9.29.5.5. , 9.29.5.8.
- hardboard finish, 9.29.7.3.
- joists, 9.23.9.2. , 9.23.9.3. , 9.23.14.9.
- lintels, 9.23.12. , 9.23.12.3.
- OSB finish, 9.29.9.3.
- particleboard finish, 9.29.9.3.
- pattern, 9.23.3.3.
- plywood finish, 9.29.6.3.
- prevention of splitting, 9.23.3.3.
- rafters, 9.23.14.4.
- roofing, 9.26.2.3.
- runners, 9.24.3.1.
- shakes, 9.27.7.3.
- sheathing, 9.23.3.5.
- shingles, 9.26.7.4. , 9.26.7.6. , 9.26.8.5. , 9.27.7.3.
- siding, 9.27.5. , 9.27.5.4. , 9.27.7.3.
- stucco, 9.28.3.2.
- subflooring, 9.23.3.5. , 9.23.15.6.
- underlay, 9.30.2.3.
- waferboard finish, 9.29.9.3.
- wall plates, 9.23.11.3.
- wood-frame construction, 9.23.3.
- wood shingles and shakes, 9.26.9.5. , 9.26.10.4.
- wood strip flooring, 9.30.3.3.
Nailing and supporting elements
Nails
- for cladding, 9.27.5. , 9.27.5.4. , 9.27.7.3.
- diameters, 9.23.3.1.
- dimensions, 9.23.3.5. , 9.26.2.3. , 9.27.5.4.
- fibreboard finish (for), 9.29.8.3.
- gypsum board (for), 9.29.5.6.
- length, 9.23.3.2.
- OSB finish (for), 9.29.9.3.
- particleboard finish (for), 9.29.9.3.
- roofing, 9.23.3.5. , 9.26.2.3.
- shingles (for), 9.26.7.4.
- siding, 9.27.5.4.
- size, 9.23.3.5. , 9.27.5.4.
- standard for, 9.23.3.1. , 9.26.2.2. , 9.29.5.6.
- underlay (for), 9.30.2.3.
- waferboard finish (for), 9.29.9.3.
- Neutralizing and Dilution Tanks 7.4.4.4.
- Neutralizing tanks for corrosive or acid waste, 7.4.4.4. , 7.5.5.3. , 7.5.7.7.
- Nitrate storage, 3.3.1.2. ,
- Noise, protection from, 5.8. , 9.32.3.10.
Nominally horizontal
Nominally vertical
- Noncombustible cladding, 3.1.4.8. , 3.1.5.5. , 3.2.3.7. , 3.2.3.8. , 9.10.14.5. , 9.10.15.5.
Noncombustible construction, 3.1.5. , 9.10.6.1.
- assembly occupancy (Group A, Division 1), 3.2.2.20. , 3.2.2.21.
- assembly occupancy (Group A, Division 2), 3.2.2.23. , 3.2.2.24.
- assembly occupancy (Group A, Division 3), 3.2.2.29. – 3.2.2.31.
- assembly occupancy (Group A, Division 4), 3.2.2.35.
- business and personal services occupancy (Group D), 3.2.2.56.
- care occupancy (Group B, Division 3), 3.2.2.42. , 3.2.2.43.
- care and treatment occupancy (Group B, Division 2), 3.2.2.38. , 3.2.2.39.
- detention occupancy (Group B, Division 1), 3.2.2.36. , 3.2.2.37.
- combustible elements, 3.1.5.8. , 3.1.5.19. , 9.10.6.1.
- combustible finishes in, 3.1.5.12.
- combustible flooring in, 3.1.5.10.
- combustible insulation in, 3.1.5.14.
- combustible piping materials, 3.1.5.22.
- combustible plumbing fixtures, 3.1.5.20.
- combustible stairs in, 3.1.5.11.
- decorative wood cladding, 3.1.5.24.
- definition, 1.4.1.2. [A]
- ducts (combustible) in, 3.1.5.18.
- exposing building face, construction of, 3.2.3.7.
- exterior walls, 3.1.5.5. , 3.1.5.6.
- factory-assembled panels, 3.1.5.7.
- fire blocks, 3.1.11.3.
- firewall collapse prevention, 3.1.10.1.
- firewalls, 3.1.10.2.
- flame-spread rating, 3.1.13.8.
- glazing and skylights, 3.1.5.4.
- high-hazard industrial occupancy (Group F, Division 1), 3.2.2.72. ,
- low-hazard industrial occupancy (Group F, Division 3), 3.2.2.82. – 3.2.2.84. , 3.2.2.91. - 3.2.2.92. , 3.2.3.11.
- materials permitted in, 3.1.5.1.
- medium-hazard industrial occupancy (Group F, Division 2), 3.2.2.82. , 3.2.2.83.
- mercantile occupancy (Group E), 3.2.2.66.
- metal roof decks, 3.1.14.2.
- minor combustible components, 3.1.5.2.
- nailing elements, 3.1.5.8.
- noncombustible materials, 3.1.5.1.
- non-metallic raceways in, 3.1.5.23.
- partitions in, 3.1.5.16.
- plumbing fixtures, 3.1.5.20.
- residential occupancy (Group C), 3.2.2.47. , 3.2.2.49.
- roofing materials, 3.1.5.3.
- support, 3.1.7.5. , 9.10.8.4.
- vehicular passageways, 3.2.3.19.
- walkways, 3.2.3.19. , 3.2.3.20.
- wires and cables, 3.1.5.21. , 3.1.5.22.
Noncombustible (material), 1.4.1.2. [A]
- Noncombustible piping, 7.2.5.12.(5)
- Non-ferrous pipe and fittings, 7.2.7.
- Non-metallic pipe and fittings, 7.2.5.
Nonmetallic raceway, 3.1.4.3. , 3.1.5.23. , 3.1.9.3. , 3.6.4.3.
- noncombustible construction (in), 3.1.5.20.
Non-potable rainwater harvesting systems
Non-potable water systems, 7.7.
- Notching of framing members, 9.23.5.2.
- Nuts, 7.2.10.2. , 7.2.10.3.
O
- Objectives of the Code, 1.2.1.1. [A], 1.4.1.2. [A], 2.2. [A]
Obstructions, 3.2.5.3. , 3.3.1.9. , 3.3.1.24. , 3.8.1.3. , 3.8.3.2. , 3.11.3.1. , 3.15.5.1. , 9.9.5.
Occupancy,
- Occupancy combinations, prohibition, 3.1.3.2. , 3.10.2.1. , 9.10.9.13.
Occupant load, 3.1.17. , 3.2.1.1. , 3.2.6.1. , 9.10.18.2.
- Odour removal equipment, 6.3.2.13. , 6.8.1.3. , 9.33.6.14.
- Office areas, 4.1.5.3.
Offset relief vents
Offsets in piping, 1.4.1.2. [A]
- Oil interceptors (see interceptors)
- Oil-burning equipment, 9.33.5.2.
- Open-air storage garages, 9.10.18.8.
Openings
- in barrier-free path of travel, 3.8.3.2.
- care, treatment or detention occupancy, 3.3.3.2.
- ducts, 3.1.8.8. , 3.1.9.5. , 6.3.2.9. , 6.9.2.4. , 9.10.5.1. 9.33.6.10.
- escalators, 3.2.8.2.
- in exposing building face, 9.10.14. , 9.10.15.
- exterior walls, (see also unprotected openings), 3.2.3. , 9.9.4.4. – 9.9.4.6. , 9.10.12.1. , 3.2.3.13. , 3.2.3.17. , 9.10.12. , 9.10.14. , 9.10.15.
- fire dampers (for), 9.24.3.7.
- fire separations, 3.1.8.1. , 3.1.8.6. , 3.1.9.5. , 3.3.3.2. , 3.4.4.4. , 9.10.5. , 9.10.9.3. , 9.10.13. , 9.10.13.8.
- firefighting access (for), 3.2.5.1. – 3.2.5.2. , 9.10.20.
- floor assemblies (through), interconnected floor spaces, 3.2.8. , 9.10.1.3.
- in garage floors, 3.3.5.4.
- guards, 3.3.1.18. , 3.3.2.9. , 3.4.6.6. , 9.8.8.5. , 9.8.8.6.
- membrane ceilings, 3.1.9.5. , 9.10.5.
- moving walks, 3.2.8.2.
- natural ventilation, 9.32.2.2.
- near exterior exits, 9.9.4.4. – 9.9.4.6.
- onto landings, 3.4.6.4.
- repair garages, 3.3.3.2.
- soffit (above door/window), 3.2.3.16. , 9.10.12.4.
- stairways, 3.2.8.2.
- support of masonry above, 9.20.5.2. , 9.22.1.2.
- vehicular passageways, 3.2.3.18.
- walls above adjoining roof, 3.2.3.15. , 9.10.12.2.
- in walls exposed to adjoining roof, 3.2.3.15.
- Operating rooms, 3.3.3.6. , 4.1.5.3.
- Oriented strand board (see OSB)
- Organization, 1.3.2. , 1.5.2. [A]
OSB
- cladding, 5.10.1.1. , 9.27.10.
- fire blocking, 3.1.11.7. , 9.10.16.3.
- fire protection of soffits, 9.10.12.4.
- firestopping, 3.1.11.7.
- interior finish, 9.29.9.
- material, 9.3.2.4.
- material standard, 5.9.1.1. , 5.10.1.1. , 9.23.15.2. , 9.23.16.2. , 9.23.17.2. , 9.27.10.1. , 9.29.9.1. , 9.30.2.2.
- roof sheathing, 9.3.2.4. , 9.23.16.2. , 9.23.16.3.
- siding, 5.10.1.1. , 9.27.10.
- subflooring, 9.3.2.4. , 9.23.15.2. , 9.23.15.5.
- thickness, 9.29.9.2.
- tolerances, 9.3.2.7.
- underlay, 9.30.2.2.
- wall sheathing, 9.3.2.4. , 9.23.3.5. , 9.23.10.2. , 9.23.13. , 9.23.17.2. , 9.23.17.5.
Outdoor
- Outdoor assembly, 3.3.2.11.
- Outdoor pool, 1.3.3.2. [A], 1.3.1.1. [A]., 1.4.1.2. [A], 3.11.
Outlet boxes, electrical, 3.1.5.2. ,
- Outlets for non-potable water system, 7.7.1.2. , 7.7.1.4. , 7.7.3.2.
- Ovens, fire protection, 9.10.22.
Overflows
P
Paint, 3.1.5.2. , 9.17.3.3. , 9.20.5.2. , 9.23.8.2. , 9.28.4.1.
- Paper, 3.1.5.13.
Parapets, 3.1.5.3.
Parging
Parking area
- Parking decks on roofs, 4.1.5.5.
- Parking structures design basis, 4.4.2.1.
Particleboard
- interior finish, 9.29.9.
- material standard, 9.29.9.1.
- subflooring, 9.23.15.2. , 9.23.15.5.
- thickness, 9.29.9.2.
- underlay, 9.30.2.2.
Partitions, 1.4.1.2. [A], 3.1.8.1. , 3.1.13.1. , 3.2.1.1. , 3.3.1.12.
Party walls,
- definition, 1.4.1.2. [A]
- fire separations, 9.10.9.
- as firewalls, 9.10.11.1.
- not as firewalls, 9.10.11.2.
Passageways, exterior
- as access to exit, 9.9.9.3.
- exemptions, 3.4.4.3.
- as exits, 3.3.1.15. , 3.4.1.5.
- fire-resistance rating, 9.10.8.8.
- fire separations, 9.9.4.2.
- flame-spread rating, 9.10.17.4.
- interior finishes, 3.1.13.10.
- as means of egress, 3.2.2.12.
- Passenger elevating device dimensions, 3.5.4.1.
- Passenger loading zones, 3.8.2.2.
- Passenger pickup areas, barrier-free, 3.8.2.2.
Path of travel, barrier-free
- apartment buildings, 3.8.2.1. , 9.5.2.3.
- application of Code, 3.8.1.1.
- doors and doorways, 3.8.3.3.
- drinking fountains, 3.8.3.16.
- elevators, 3.3.1.7. , 3.8.1.3. , 3.8.3.5.
- exterior, 3.8.1.2. , 3.8.1.3. , 3.8.2.2. , 3.8.3.2. ,
- floor areas, 3.3.1.7. , 9.5.2.2.
- parking areas, 3.8.2.2.
- protruding building elements, 3.3.1.8.
- signs, 3.8.3.1.
- storage garage, 3.8.2.2.
- universal shower and dressing room, 3.8.3.13.
- universal washrooms, 3.8.3.12.
- walkways, 3.8.1.2.
- wheelchair spaces, 3.8.2.1. , 3.8.3.6.
- width, 3.8.1.3.
- Patients’ bedrooms, 4.1.5.3.
- Paved surfaces, hydraulic loads, 7.4.10.1. , 7.4.10.4.
- PE/AL/PE (polyethylene/aluminum/polyethylene) pipe and fittings, 7.2.5.12. , 7.3.4.5.
- Peak demand flow, 7.6.3.4.
- Peak electrical demand, 7.2.3.1.
- Pedestrian thoroughfares, 3.2.3.20. , 3.15.5.2.
- Penetrations in fire assemblies, 3.1.4.2. , 3.1.5.23. , 3.1.9.
- Penthouses, 3.2.1.1. , 3.6.1.1. ,
- Perched groundwater, 1.4.1.2. [A], 3.1.19.1.
- Permafrost, 4.2.4.10. , 9.15.1.2.
- Personal hygiene devices, 7.2.2.2.
- PE-RT (polyethylene of raised temperature) tube and fittings, 7.2.5.15. , 7.3.4.5.
- PEX/AL/PEX (crosslinked polyethylene/aluminum/cross-linked polyethylene) composite pipe and fittings, 7.2.5.13. , 7.3.4.5.
Piers
- carport, 9.35.3.4.
- anchoring to, 9.20.11.6.
- dimensions, 9.35.3.4.
- Pier-type foundations, 9.15.2.3.
- Pilasters, 9.15.5.3. , 9.20.8.4.
- Piles, 1.4.1.2. [A], 4.1.8.16. , 4.2.3.8. , 4.2.4.1.
Pipe
- ABS, 7.2.5.10. , 7.3.4.5.(2)
- acid and corrosive, 7.2.8.1.
- applications, summary of, 7.2.5. , 7.2.7.
- asbestos-cement, 7.2.5.1. , 7.3.4.5.(2) , 7.3.5.2.
- bell and spigot, 7.3.2.7.
- brass, 7.2.7.1.(2) , 7.2.7.2. , 7.3.4.5.(2)
- cast-iron, 7.2.6.1. , 7.2.6.4. , 7.3.3.3. , 7.3.3.8. , 7.3.4.5.
- cast iron soil, 7.2.6.1. , 7.2.6.2. , 7.3.3.3. , 7.3.4.5.(2)
- cast iron water, 7.2.6.4. , 7.3.4.5.(2)
- cellular core PVC, 7.2.5.16.
- chlorinated poly (vinyl chloride) (CPVC), 7.2.5.9. , 7.3.4.5.(3)
- combustible, 7.2.5.10.(4)
- concrete, 7.2.5.3.
- copper, 7.2.7.1.(1) , 7.3.4.5.(2)
- corrosion-resistant, 7.2.8.
- corrugated steel, 7.2.6.8.
- crosslinked polyethylene, 7.2.5.6.
- ductile-iron water, 7.2.6.4.
- ferrous, 7.2.6.
- fibrocement, 7.2.5.1.
- flanges and fittings, brass or bronze, 7.2.7.2. , 7.2.7.3.
- hangers, 7.3.4.3. , 7.3.4.5.
- hub and spigot, 7.3.2.1.(4)
- hydraulic loads, 7.4.10.1.
- joints and connections, 7.3.2. , 7.3.3.
- lead waste, 7.2.7.8. , 7.3.4.5.(2)
- marking of, 7.2.1.3. , 7.7.2.1.
- noncombustible, 7.2.5.10.
- non-ferrous, 7.2.7.
- non-metallic, 7.2.5.
- open end, 7.4.6.1.(2)
- PE/AL/PE, 7.2.5.12. , 7.3.4.5.
- PEX/AL/PEX, 7.2.5.13. , 7.3.4.5.
- plastic, 7.2.5.9. , 7.2.5.10. , 7.3.4.5.(2) , 7.6.1.10.
- polyethylene water, 7.2.5.5.
- poly (vinyl chloride) (PVC), 7.2.5.8. , 7.3.4.5.
- protection of, 7.3.5. , 7.4.4.
- sheet metal, 7.2.6.9.
- size of, 7.4.9.
- steel, 7.2.6.7. , 7.2.6.8. , 7.3.3.3. , 7.3.4.5.(2) , 7.2.6.7. , 7.2.6.8. , 7.2.6.10. , 7.2.6.15. , 7.3.3.3. , 7.3.4.5.
- subsoil drainage, 7.4.5.3. , 7.4.6.4.(5)
- underground, 7.3.4.6. , 7.3.5.1.
- vitrified clay, 7.2.5.4. , 7.3.5.2.
- water service, 7.2.1.6. , 7.6.1.3. , 7.6.1.5. , 7.6.1.10. , 7.6.3.4.
- water supply, 7.6. , 7.7.
- welded and seamless steel, 7.2.6.7.
Pipes
- clearances, 6.7.1.2. , 9.33.8.3.
- combustible, 3.1.5.19. , 3.1.9.4. , 9.10.9.6. , 9.10.9.7.
- coverings, 6.5.1.1.
- drain, waste, and vent, 3.1.9.4. , 9.10.9.7.
- drainage, 9.14.3.
- expansion and contraction, 6.7.1.1.
- heating and cooling systems (for), 6.7.1.1.
- insulation, 6.5.1.1.
- materials, 6.7.1.1.
- metal, 9.14.3.1. , 9.31.2.2.
- in noncombustible construction, 3.1.5.19. , 3.1.5.20.
- penetrating fire separations, 3.1.9.1. , 3.1.9.2. , 3.1.9.4. , 9.10.9.6. , 9.10.9.7.
- plumbing, 9.31.2.2.
- polypropylene, 3.1.5.19.
- protection from corrosion, 9.31.2.2.
- shafts (in), 6.7.1.5.
- sleeves, 6.7.1.4.
- standards for drainage, 9.14.3.1.
- support, 6.7.1.1.
Piping
- combustible, 7.2.5.11.
- construction and use of joints, 7.3.2.
- contraction accommodation, 7.3.3.9.
- CPVC design temperature and pressure, 7.2.5.8.
- drainage of, 7.6.1.2.
- expansion accommodation, 7.3.3.9.
- horizontal, 7.3.4.5. , 7.3.4.6.
- installation of, 7.3.3 9., 7.3.3.10. , 7.3.5.3.
- joints and connections, 7.3.3.
- maximum pressure on, 7.2.1.5.
- minimum pressure, 7.2.1.5.
- noncombustible, 1.4.1.2. [A], 7.2.5.11.
- nominally horizontal, 7.3.4.5. , 7.3.4.6.
- protection of, 7.3.5. , 7.4.4.
- service, 7.1.6.2.
- support of, 7.3.4.
- system, design temperature and pressure of (CPVC), 7.2.5.9.(2)
- testing of, in drainage and venting systems, 7.3.6.
- testing of, potable water systems, 7.3.7.
- vertical, 7.3.4.4.
- Plank construction, 9.3.2.1.
- Plaster material standard, 9.29.4.1.
- Plastering, 9.29.4.
- Plastic light diffusers and lenses, 3.1.13.4. , 9.10.17.8.
- Plastic fixtures, 7.2.2.2.
- Plastic pipe and fittings, 7.2.5.9. , 7.2.5.10.
Plates
- Platform equipped passenger-elevating device, 3.8.3.5.
- Platforms, serving as roofs, 9.26.1.1.
- in air duct systems, 3.6.5.1. , 6.3.2.3.
- ceiling assemblies used as, 3.1.9.6.
- ceilings used as, 3.6.4.3.
- clearances, 6.3.2.6.
- connectors, 9.33.6.2.
- construction, 6.3.2.3. , 6.3.2.6A. , 9.33.6.6
- coverings, 9.33.6.4.
- crawl spaces used as, 9.18.7.1.
- definition, 1.4.1.2. [A]
- fittings, 6.3.2.3. , 9.33.6.2.
- furnace, 9.33.6.6. , 9.33.6.7. , 9.33.6.8.
- insulation, 6.3.2.5. , 9.33.6.4.
- linings, 3.6.5.4. , 6.3.2.5. , 9.33.6.4.
- materials, 6.3.2.3. , 9.33.6.2. , 9.33.6.3.
- in noncombustible construction, 3.1.5.18.
- return air, 3.6.4.3. , 9.32.3.4.
- tape used for, 6.3.2.19.
- Plumbing facilities, 7.1.4.1. , 9.31.
Plumbing, (see also Fixtures), Part 7
- Plumbing services, Part 7
- Plumbing fixtures 7.4.3.1.
Plumbing systems
Plywood
- cladding, 5.10.1.1. , 9.27.2.4. , 9.27.3.6. , 9.27.5. , 9.27.8.
- fastening, 9.29.6.3.
- fire block, 3.1.11.7. , 9.10.16.3.
- fire protection of soffits, 9.10.12.4.
- firestops, 3.1.11.7.
- grooved, 9.29.6.2.
- installation, 9.29.6.3. , 9.29.6.4.
- interior finish, 9.29.6.
- lapped strips, 9.27.8.5.
- material, 9.3.2.4.
- material standards, 5.10.1.1. , 9.23.15.2. , 9.23.16.2. , 9.23.17.2. , 9.27.8.1. , 9.30.2.2. ,
- nailing, 9.29.6.3.
- roof sheathing, 9.3.2.4. , 9.23.16.1. - 9.23.16.3.
- siding, 5.10.1.1. , 9.27.8.
- stapling, 9.29.6.3.
- subflooring, 9.23.15.2. , 9.23.15.5.
- thickness, 9.29.6.1.
- underlay, 9.30.2.2.
- wall sheathing, 9.23.3.5. , 9.23.10.2. , 9.23.13. , 9.23.16.2. , 9.23.17.2. , 9.23.17.5.
- Police stations, 3.1.2.4.
- Polyethylene/aluminum/polyethylene (PE/AL/PE) pipe and fittings, 7.2.5.12. , 7.3.4.5.
- Polyethylene pipe and fittings, 7.2.5.4. , 7.2.5.5. , 7.3.4.5
- Polyethylene water pipe, 7.2.5.5.
- Polypropylene pipe and fittings, 7.2.5.14. , 7.3.4.5.
- Poly (vinyl chloride) (PVC) pipe and fittings, 7.2.5.8. , 7.3.4.5.(2)
- Porcelain-enamelled fixtures, 7.2.2.2.
- Portable fire extinguishers, (see Extinguishers, portable)
Post-disaster buildings,
- Potable, definition, 1.4.1.2. [A]
Potable water systems, 7.6.
- arrangement of piping for, 7.6.1.
- connections of, to potable and non-potable water systems, 7.6.2.1. , 7.7.1.1.
- design of, 7.3.4.2. , 7.6.3.
- drainage, 7.6.1.2.
- lead content, restrictions on use, 7.2.9.2.
- protection of, from contamination, 7.6.2.
- required, 9.31.3.
- size and capacity of pipes, 7.6.3.
- solar heating, 7.2.10.13. , 7.6.1.8
- tanks for, 7.3.4.2.
- testing of, 7.3.7.
- Potato peelers, 7.4.3.3. , 7.4.9.3.
- Power operated doors, 3.8.3.3.
Precipitation, 5.6.
- Premise isolation, 7.6.2.6.
Pressure (see also Back pressure)
- Pressure reducing valves, 7.2.10.12. , 7.6.1.11. , 7.6.3.3. , 7.7.1.1. , 7.7.2.4.
- Pressure relief valves, 7.2.10.11. , 7.6.1.12.(1)
- Prestressed concrete, 4.3.3.1.
- Pressure piping, 9.33.5.2.
- Pressure vacuum breaker, 7.6.2.2. , 7.6.2.10.
- Private sewage disposal systems, 7.4.4.1. , 8.1.2.1.
- Private sewer, definition, 1.4.1.2. [A]
- Private use, 1.4.1.2. [A], 7.6.3.2. , 7.6.3.4.
- Private water supply system, 1.4.1.2. [A], 7.1.2.3. , 7.6.2.5.
Process plants
Protection from freezing, (see freezing, protection from)
- concrete, 9.3.1.9.
- concrete stairs, 9.8.10.3.
- excavations, 9.12.1.3.
- fire hose stations, 9.10.21.9.
- fire protection systems, 3.2.5.18. , 9.10.20.5.
- foundations, 9.12.1.3.
- gypsum board, 9.29.5.10.
- HVAC systems and equipment, 6.2.1.6. , 9.33.4. , 9.33.4.5.
- masonry, 9.20.14.1.
- stucco, 9.28.6.1.
- Protection from high temperature piping, 6.7.1.4. , 9.33.8.4.
- Protection of piping, 7.3.5.
Public areas (see also Corridors)
Public corridors, 3.2.7.3. , 3.3.1.1. , 3.3.1.9. , 3.3.1.13. , 3.3.4.4. , 9.9.3.3. , 9.9.5.3. , 9.9.7.2. , 9.9.9.1. - 9.9.9.3.
- access to exit, 9.9.9.1. , 9.9.9.3.
- containing occupancy, 9.10.17.7.
- definition, 1.4.1.2. [A]
- doors and door hardware, 3.3.1.13.
- doors opening onto, 9.10.13.12.
- emergency lighting, 3.2.7.3. , 9.9.12.3.
- exit signs, 3.4.5.3
- fire separations, 3.3.1.4.
- flame-spread rating, 3.1.13.6. , 3.1.13.7. , 9.10.17.
- lighting (in), 3.2.7.1. , 3.2.7.3. , 9.9.12.2. , 9.9.12.3.
- serving sprinklered buildings, 3.3.1.1.
- smoke control measures, 3.2.6.2.
- travel distance to exit, 3.4.2.5.
- travel distance, 3.4.2.4. , 3.4.2.5.
- width, 3.3.1.9.
- Public heritage buildings, 1.4.1.2. [A], Part 11
- Public pools, 1.4.1.2. [A], 3.11. , 9.1.1.10.
- Public spas, 1.4.1.2. [A], 3.12. , 9.1.1.10.
- Public thoroughfares, 3.2.3.1. , 3.2.3.9. , 3.2.5.6. , 9.10.14.2. , 9.10.15.2. , 9.10.20.3.
Public ways
- Public use, 1.4.1.2. [A], 7.2.2.5. , 7.6.3.2.
- Public washrooms, 7.2.2.5. , 7.2.10.6.
- Pumps for sumps, 7.4.6.3.
- PVC (polyvinyl chloride) pipe and fittings, 7.2.5.7. , 7.3.4.5.
Pyritic soil and rock
Q
- Quarter bend fittings, 7.2.4.3.
R
Raceways, electrical, 3.1.5.21 , 3.1.5.23. , 3.1.9.2. , 3.1.9.3. , 3.6.4.3. , 9.10.9.9.
- Radiation from interior fires, control, 3.2.3.1. , 9.10.3.3. , 9.10.14. , 9.10.15.
- Radiators, 6.7.1.3.
Radon gas infiltration, (see soil gas control)
Rafters
- anchoring to masonry, 9.20.11.4.
- bearing, 9.23.14.3. , 9.23.14.5.
- continuity, 9.23.14.1.
- deflection, 9.4.3.1.
- dimensions, 9.23.4.2. , 9.23.15.6. , 9.23.15.7.
- fastening, 9.23.3.4. , 9.23.14.4.
- framing around openings, 9.23.14.2.
- hip and valley, 9.23.14.6.
- installation, 9.23.14.4.
- lumber grade, 9.3.2.1.
- nailing, 9.23.14.4.
- ridge support, 9.23.15.8.
- shaping, 9.23.14.5.
- size, 9.23.4.1. , 9.23.4.2. , 9.23.14.6. , 9.23.14.7.
- spans, 9.23.4.1. , 9.23.4.2. , 9.23.14.7.
- support, 9.23.14.7. , 9.23.15.3. , 9.23.15.7.
- in wood frame construction, 9.23.4.2. , 9.23.15.
- Rainfall, and hydraulic load, 7.4.10.4.
- Rain loads, 4.1.6.4. , 4.1.6.12. , 9.4.2.2.
- Rain penetration control, 5.6. , 9.20.13. , 9.26. , 9.27.4. – 9.28.
- Rainwater harvesting systems, 7.7.2.
- Rainwater tanks, overflows, 7.4.2.2. , 7.7.2.4
Ramps, 3.3.1.14. , 3.4.1.4. , 9.8.5.
- barrier-free, 3.8.3.4. , 9.8.5.1. , 9.8.6.1.
- barrier-free floor areas, 3.3.1.7.
- basement, 3.4.5.2.
- doors (at), 9.8.6.3.
- for dwelling units, 9.8.1.
- exits (as), 9.9.2.1.
- exit signs, 9.9.11.4.
- finish, 9.8.9.6.
- in garages, 9.8.8.4.
- guards, 3.8.3.4. , 9.8.8.1. , 9.8.8.3.
- handrails, 3.4.6.5. , 3.8.3.4. , 9.8.7.7.
- height, 9.8.5.5.
- height over, 9.8.5.3.
- for housing and small buildings, 9.8.5.
- landings, 9.8.6.3.
- loads, 9.8.9.1.
- rise, 9.8.5.5.
- safety requirements, 3.3.1.14.
- for secondary suites, 9.8.5.
- slip-resistance, 3.4.6.1.
- slope, 3.4.6.7. , 3.8.3.4. , 9.8.5.4.
- storage garages, 9.8.8.4.
- width, 3.4.3.2. , 3.8.3.4. , 9.8.5.2.
- Receptacles, electrical, 9.34.2.2.
- Recessed lighting fixtures, 3.2.7.2. , 9.34.1.4.
- Receiving tanks, 7.4.6.3.
- Reducer fittings, 7.3.3.5.
- Reducing valves, 7.2.10.12. , 7.6.1.11.
- Reducer fittings, 7.3.3.5.
- Referenced documents, 1.5.1. [A]
Refrigerating systems and equipment, 6.2.10.
Refuse
- bins, 3.6.3.3.
- chutes, 3.6.3.3. , 5.8.1.1. 9.10.1.3.
- combustible, 9.10.10.6.
- rooms, 3.6.2.5. , 3.6.3.3. , 9.10.10.6.
Registers and outlets (see also Air outlets, Diffusers)
- exhaust, 6.3.2.10. , 9.32.3.13. , 9.33.6.14A.
- heating, 9.33.6.10A. , 9.33.6.11.
- over pipeless furnaces, 9.33.6.8.
- ventilation, 9.32.3.5. , 9.32.3.6.
- Reinforced concrete, 4.3.3.1. , 9.3.1.1. , 9.39.
Reinforcing
Relief valves
- discharge pipe for, 7.6.1.12.
- specifications for, 7.2.10.11.
Relief vents, 1.4.1.2. [A]
- Renovation, 1.3.3.3B. [A], Part 11
Repair garages, 1.4.1.2. [A]
- design, 4.4.2.1.
- fire separation requirements, 9.10.9.19.
- in industrial occupancies, 3.3.5.4.
- separation from care, treatment or detention occupancies, 3.3.3.2.
- solid-fuel burning appliances prohibited in, 3.6.2.1.
- Residential fire warning systems, 3.2.4.21. , 9.10.19.8.
- Residential full flow-through fire sprinkler/standpipe system, 1.4.1.2. [A], 7.6.2.4.
Residential occupancy (Group C), 1.4.1.2. [A]
- below ground level, 3.2.2.15.
- building construction, 9.10.8.
- classification, 3.1.2.1. , 3.1.2.5. , 9.10.2.
- convalescent and children's homes as, 3.1.2.5.
- door hold-open devices, 3.1.8.14.
- emergency power for fire alarm systems, 3.2.7.8.
- emergency power for lighting, 3.2.7.4.
- fire access route design, 3.2.5.6
- fire alarm systems, 3.2.4.1. , 3.2.4.11. , 3.2.4.18. , 9.10.18.
- fire protection, 3.2.2.47. - 3.2.2.55.
- fire-resistance rating, 9.10.8.
- fire safety within floor areas, 3.3.1. , 3.3.4.1.
- fire separations, 9.10.9.13. , 9.10.9.16.
- flame-spread rating, 3.1.13.3. , 9.10.17.
- lighting requirements, 3.2.7.1.
- location of smoke/fire dampers, 3.1.8.7.
- occupant load, 3.1.17.1.
- ramp slope maximum, 3.4.6.7.
- smoke alarms, 3.2.4.20. , 9.10.19.
- smoke control measures, 3.2.6.2.
- sprinkler piping, 3.2.5.13.
- sprinkler systems, 3.2.5.12.
- storage lockers, 3.1.5.17.
- water closets required, 9.31.4.1.
- Residential partial flow-through fire sprinkler/standpipe system, 1.4.1.2. [A], 7.6.2.4.
Resilient flooring, 9.30.5.
- Resistance to deterioration (see also Corrosion protection, Corrosion resistance, Decay, protection against), 3.7.4.11. , 4.2.3.4. , 5.1.4.2. , 9.3.2.9. , 9.20.16.1. , 9.27.2.1.
Resistance to forced entry
- Resistant design, earthquake load, 4.1.3.2.
Restaurants, (see also Food premises) 3.1.2.6. , 3.1.17.1. , 3.3.2.15. , 3.7.4.3. , 4.1.5.6. , 8.2.1.3.
- ventilation of, 6.3.1.6.
- Retirement homes, 1.4.1.2. [A], 3.2.2.55A. to 3.2.2.55E. , 3.2.4.7. , 3.2.5.12. , 3.2.6.8. , 3.18.1.1. , 10.1.1.2. , 10.3.2.2. , 11.3.3.1. , 11.3.3.2. , 11.4.2.3. , 11.4.3.4. , 1.3.1.4. [C]
- Return air inlets, 9.33.6.12.
- Return air systems (see also Air inlets, Ducts), 3.6.5.8. , 6.3.2.11. , 9.33.6.12. , 9.33.6.13.
- Return ducts (see also Ducts, return), 1.4.1.2. [A]
- Review (general), 1.2.2. [C]
- Revolving doors, 3.4.6.15. , 9.9.6.4.
Rim joists
Risers, plumbing
Risers, stair
- Rock, 1.4.1.2. [A], 9.4.4.1. , 9.4.4.2. , 9.12.2.2.
Rock, pyritic
- Roof aggregate, 9.26.11.1. , 9.26.11.4.
Roof assemblies
- fire-resistance rating, 3.1.7.5. , 3.2.2.17. , 3.2.2.25. , 3.2.2.35. , 3.2.2.50. , 3.2.2.53. , 3.2.2.58. , 3.2.2.62. , 3.2.2.68. , 3.2.2.78. , 3.2.2.83. , 3.2.2.85.
- fire-retardant-treated wood roof systems, 3.1.14.1.
- gymnasiums, swimming pools, arenas and rinks, 3.2.2.17.
- metal roof deck assemblies, 3.1.14.2.
- non-contiguous, 3.1.15.2. , 3.2.2.51. , 3.2.2.60.
Roof and ceiling framing,
- bearing on cavity walls, 9.20.8.2.
- earthquake design, 4.1.8.18.
- fire-resistance rating, 3.1.7.3.
- in heavy timber construction, 3.1.4.7.
- loads on, 9.4.2.2. , 9.4.2.4.
- in noncombustible construction, 3.1.5.3.
- sheathing (see also Sheathing, roof), 3.1.5.3. 9.3.2.4. , 9.23.16.
- trusses, 9.4.2.4. , 9.23.5.5. , 9.23.14.11.
- in wood-frame construction, 9.23.14.
Roof covering (see also Roofing), 3.1.15.1. , 9.26
- classification, 3.1.15.2.
Roof drains, (see also drains), 5.6.2.2. , 9.26.18.1.
- Roof gutters, 1.4.1.2. [A], 7.4.10.4.
Roof spaces, 3.1.11. , 3.8.2.1. , 9.10.16.1. , 9.19.
Roof-top
Roofing (see also Roof covering),
- asphalt-coated glass-base sheets, 5.9.1.1.
- asphalt shingles, 5.6.1.2. , 5.10.1.1. , 9.26.1.3. , 9.26.2.1. , 9.26.7. , 9.26.8.
- bituminous, 9.26.2.1.
- built-up, 5.10.1.1. , 9.26.11.
- built-up materials, 9.26.2.1.
- cedar shingles, 9.26.2.1. , 9.26.3.1. , 9.26.10.
- clay tile, 9.23.4.5.
- concrete tile, 5.10.1.1. , 9.23.4.5. , 9.26.2.1. , 9.26.17.
- definition, 9.26.1.1.
- elastomeric sheets, 5.9.1.1. , 9.26.2.1.
- fasteners, 9.26.2.2. , 9.26.2.3.
- flashing, 9.26.4.
- installation alternatives, 9.26.1.3.
- installation of materials, 9.26.2.2.
- installation standards, 5.6.1.2
- limiting slopes, 9.26.3.
- material standards, 9.26.2.1.
- metal, 9.26.13.
- nails, 9.26.2.2.
- over wood-based sheathing, 9.26.11.8.
- polyester, 5.10.1.1. , 9.26.14.
- polyvinyl chloride sheets, 5.10.1.1. , 5.6.1.3. , 9.26.2.1. , 9.26.16.
- prefabricated bituminous membranes, 9.26.2.1.
- prefabricated modified bituminous sheets, 5.10.1.1.
- requirement for, 5.6.1.1. , 9.26.1.1.
- rubberized asphalt, 5.10.1.1. , 9.26.2.1. , 9.26.15.
- selvage, 9.26.12.
- slope of, 9.26.3.
- standards for, 5.10.1.1.
- staples, 9.26.2.3.
- wood shingles and shakes, 5.10.1.1. , 9.26.9. , 9.26.10.
Roofs
- access, 3.2.5.3.
- access from, 3.3.1.3.
- acting as diaphragms, 4.1.8.15. , 4.1.8.18.
- anchorage of intersecting, 9.20.11.
- appliances mounted on, 3.6.1.5. , 6.4.1.2. , 9.10.1.4.
- arched or curved, snow loads, 4.1.6.10
- beams, 9.23.4.1.
- combustible elements permitted, 3.1.5.3.
- considered as walls, 3.2.1.3. , 9.10.1.1.
- definition, 9.26.1.1.
- deflection, 9.4.3.1.
- drains, (see roof drains)
- egress from, 3.3.1.3. , 9.9.7.1.
- fire blocks, 9.10.16.1.
- fire rating, 9.10.3.3.
- fire exposure from, 3.2.3.15. , 9.10.12.2.
- fire-resistance rating, 3.2.2. , 3.2.2.17. , 9.10.8.1. , 9.10.8.2. , 9.10.8.7.
- fire-retardant treated wood, 3.1.14.1.
- fire separation, 3.2.2.13.
- firewall termination, 3.1.10.3.
- framing, 9.23.4. , 9.23.14.
- framing around openings, 9.23.13.2.
- gable, snow loads, 4.1.6.9.
- guards, 3.3.1.18. , 9.8.8.1.
- heavy timber construction, 3.1.4.7. , 3.2.2.16.
- helipad loads, 4.1.5.13.
- hydraulic load from, 7.4.10.4
- insulation, 9.25.2.3.
- joists, 9.23.4.2. , 9.23.4.5. , 9.23.14.1. , 9.23.14.7. , 9.23.14.9.
- loads due to use, 4.1.5.
- metal decking, 3.1.14.2.
- multi-level, 4.1.6.5. , 9.4.2.2.
- in noncombustible construction, 3.1.5.3.
- parapets, 3.1.5.3. , 3.1.10.4. , 4.1.7.5. , 4.1.7.6. , 4.1.8.1. , 4.1.8.18. , 5.6.2.2. , 9.20.6.5.
- rain loads, 4.1.6. , 9.4.2.2.
- ridge support, 9.23.13.8.
- scuppers, 4.1.6.4.
- sheathing installation, 9.23.15.2. , 9.23.15.3. , 9.23.15.6.
- sheathing materials, 9.3.2.1. , 9.3.2.4. , 9.23.15.1. , 9.23.15.5. , 9.23.16.7.
- sloped, 4.1.6.12. , 9.10.1.1
- snow loads, 4.1.6. , 9.4.2.2.
- sprinklers in lieu of structural fire resistance, 9.10.8.2.
- supporting occupancy, 3.2.2.13. , 9.10.8.7.
- trusses, 9.4.2.2. , 9.23.5.5. , 9.23.14.11.
- of underground structures, 9.13.1.1. , 9.13.3.
- venting, 9.19.1.
- wind loads, 4.1.7.6. , 5.2.2.2.
- Roof spaces (see Attics or roof spaces)
Rooftop
- Rooms, height, (see height, rooms)
- Rubber gasket joints, 7.2.5.2. , 7.2.6.4.(4)
Run, stairs,
Runners, sheet steel framing
S
- Saddle hubs or fittings, 7.2.10.5.
Safety glass, 3.3.1.20. , 3.4.1.8. , 3.4.6.14. , 3.7.4.10. , 9.6.1.2. , 9.6.1.4.
Sanitary building drains or sewers (see Building drains or
- Building sewers)
- definition, 1.4.1.2. [A]
Sanitary drainage pipes
Sanitary drainage systems, 1.4.1.2. [A], 3.7.4.1. , 7.4.4.1. , 7.4.7.1. , 9.31. , 9.31.2.1. , 9.31.5.
- traps 7.4.5.1.
- Sanitary sewers, 1.4.1.2. [A], 7.1.2.1. , 7.5.4.5.
- Sanitary T fittings, 7.2.4.
Screens, 3.11.11.1. , 9.32.2.2. ,
- exhaust outlets (in), 6.3.2.9. , 9.32.3.13.
- intake openings (in), 6.3.2.9.
- in natural ventilation openings, 9.32.2.2.
Screw installation
- Screwed cast iron water fittings, 7.2.6.5.
- Screwed joints, 7.3.2.3.
- Screwed malleable iron water fittings, 7.2.6.6.
Screws
Sealants
Sealing (see also Air barrier systems, Soil gas control, Waterproofing)
- against precipitation, 5.6.2.
- air barrier systems, 5.10.1.1. , 9.10.9.20. , 9.10.9.21. , 9.25.3.3.
- chimneys (at), 9.21.5.2. , 9.25.3.3.
- ducts, 6.3.2.19. , 9.33.6.6.
- gas vents (at), 9.25.3.3.
- ground cover, 9.18.6.2.
- sill plates, 9.23.7.2.
- smoke (fire), 3.1.5.19. , 3.1.9.1. , 3.1.9.4. , 3.1.11.7. , 3.3.4.2.
- waterproofing, 9.13.3.
- windows and doors, 9.7.6. , 9.20.13.11. , 9.27.4.
- Seasonally and intermittently occupied buildings, 9.37.
Seating areas
Secondary suites
- ceiling height, 9.5.3.1.
- definition, 1.4.1.2. [A]
- doors, direction of swing, 9.9.6.5.
- doors in means of egress, 9.9.6.
- doorways, 9.5.5. , 9.9.6.2. , 9.9.6.3.
- egress, 9.9.9.
- electrical outlets, 9.34.2.3.
- fire protection, 9.10.8.
- fire-resistance rating, 9.10.8.8.
- fire separations, 9.9.4. , 9.10.9.4. , 9.10.9.16. , 9.10.9.17. , 9.10.10.4. , 9.10.12.3.
- firewalls, 9.10.11.2.
- floor area limits, 9.1.2.1.
- guards, 9.8. , 9.8.8.
- handrails, 9.8. , 9.8.7.
- heating and air-conditioning, 9.33.1.1. , 9.33.3.1. , 9.33.3.2.
- Seismic category, 4.1.8.5.
- Seismic data, 1.1.3.
Seismic isolation
- Seismic loads, 4.1.8.
- Self-closing devices, 3.1.8.13. , 3.1.8.15. , 3.4.6.13. , 9.9.6.7. , 9.10.13.10. , 9.10.13.15.
- Self-closing mechanisms, 3.4.6.13.
- Self-contained emergency lighting, 3.2.7.4. , 9.9.12.3.
- Self-service storage buildings, 3.10.
- Self-storage warehouses, 9.9.6.4.
Separation
- Separation of drainage system, 7.3.5.7.
- Separation of services, 7.1.5.4. , 7.3.5.7.
- Septic disposal beds, 9.14.6.2.
- Service piping, 7.1.5.4.
- Serviceability, 4.1.3.4.
- Service counters, barrier-free, 3.8.3.14.
Service rooms,
- access to exit, 9.9.7.5.
- application of Code, 3.6.1.1.
- and building height, 9.10.4.4.
- carbon monoxide alarms, 9.32.3.9.
- construction supporting, 9.10.8.5.
- definition, 1.4.1.2. [A]
- doors, 9.10.13.12.
- doors and door hardware, 3.3.1.13. , 3.4.6.11.
- emergency lighting, 3.2.7.3.
- exits, 3.4.4.4. , 3.6.2.2.
- fire alarm systems, 3.2.4.2.
- fire detectors, 3.2.4.10.
- fire resistance of supporting construction, 3.1.7.5.
- fire separations, 3.6.2.1. , 9.10.10.3.
- heat and smoke detectors, 9.10.18.4.
- for housing and small buildings, 9.10.10.
- loads on floor or roof, 4.1.5.3.
- opening into exit, 9.9.5.9.
- ramps and stairways, 3.3.1.14.
- rooftop, 3.2.1.1. , 3.2.2.14. , 9.10.4.4.
- service equipment in, 3.6.2.3.
- under exits, 9.9.5.8.
Service spaces,
- and building height, 3.2.1.1.
- definition, 1.4.1.2. [A]
- egress, 3.3.1.25.
- emergency lighting, 3.2.7.3.
- exits, 3.4.4.4.
- fire alarm systems, 3.2.4.18.
- horizontal (see also Horizontal service spaces), 1.4.1.2. [A], 3.6.4.
- means of egress, 3.3.1.3.
- protection of electrical conductors, 3.2.7.10.
- ramps and stairways, 3.3.1.14.
- sign, 3.3.1.25.
- sprinkler systems, 3.2.5.14.
- storage use prohibition, 3.6.1.4.
- travel distance to exit, 3.4.2.4.
- vertical (see also Vertical service spaces), 1.4.1.2. [A], 3.6.3.
Sewage
- Sewage disposal systems, 1.4.1.2. [A], 7.1.5.1. , 7.4.4. ,
- Sewage sumps, venting, 7.5.5.1. , 7.5.7.7.
- Sewage treatment and disposal systems, 7.4.4. , 8.2.2.
- Sewage Treatments 7.4.4.1.
- Sewers (see Building sewers)
Shafts
Shakes, wood
- cladding, 9.27.7.
- dimensions, 9.27.7.2.
- eave protection, 9.26.5.1.
- flashing, 9.26.10.6.
- fastening, 9.27.7.3.
- grades, 9.27.7.1.
- installation, 9.26.10.3. - 9.26.10.5. , 9.27.7.3. - 9.27.7.6.
- material standards, 9.27.7.1.
- roofing, 9.26.10.
- spacing and joints, 9.26.10.3.
- underlay, 9.26.10.2.
- walls, 9.27.7.
Sheathing (see also Subflooring)
- for braced wall panels, 9.23.13.6.
- for bracing and lateral support, 9.23.10.2.
- in exposing building face, 9.10.14.5. , 9.10.15.2.
- fastening, 9.23.3.5.
- fibreboard, 9.23.16.7.
- installation, 9.23.16.3. , 9.23.16.4. , 9.23.16.6. , 9.23.17. , 9.23.17.5.
- insulating, 9.20.13.6. , 9.27.3.4.
- low permeance, 9.25.5.1.
- lumber as, 9.3.2.1. , 9.23.15.5. , 9.23.17.4.
- mansard roofs, 9.23.17.6.
- material standards, 9.23.16.2. , 9.23.17.2. , 9.26.2.1.
- membranes, 9.23.16. , 9.23.17. , 9.27.3.1. - 9.27.3.6.
- in noncombustible construction, 3.1.5.3.
- OSB, 9.23.16.1. - 9.23.16.3. , 9.23.17.2.
- plywood, 9.23.16.1. - 9.23.16.3. , 9.23.17.2.
- roofs, 9.3.2.1. , 9.3.2.4. , 9.23.16. , 9.26.2.1.
- steel studs (on), 9.24.1.5.
- stucco (beneath), 9.28.1.1. , 9.28.4.2.
- support, 9.23.10.5. , 9.24.3.4.
- thickness, 9.23.16.7. , 9.23.17.2.
- waferboard, 9.23.16.1. - 9.23.16.3. , 9.23.17.2.
- walls, 9.3.2.4. , 9.23.17.
- Sheathing membranes (see also Sheathing)
- Sheathing paper (see also Sheathing), 9.14.3.3 , 9.20.13.9. , 9.26.6.1. , 9.27.3.5.
- Sheet lead, 7.3.2.2.
- Sheet metal leaders, 7.2.6.9.
- Shelf and rack storage systems, 3.16. , 9.1.1.11.
Shingles, asphalt
Shingles, roof
Showers and shower heads
- Shower receptors, 7.2.2.3.(1)
- Shower valves, 7.6.1.1. , 7.6.5.2. , 7.6.5.3.
- Shut-off valves, 7.4.6.3.(6) , 7.6.1.3. to 7.6.1.8.
- Sidelights, 3.3.1.20. , 9.6.1.4. , 9.7.1.1. , 9.7.2.1. , 9.9.4.3.
- Sidewalks, 3.8.3.2. , 4.1.5.3. , 4.1.5.5.
Siding (see also Cladding), 9.27.
- Siding, asphalt installation, 9.27.1.1.
Siding, hardboard, 9.27.9.
Siding, lumber, 9.27.6.
Siding, metal, 9.27.11.
- installation, 9.27.5.
- material standards, 5.10.1.1. , 9.27.11.1.
Siding, OSB and waferboard, 9.27.10.
- clearances, 9.27.10.4.
- dimensions, 9.27.10.2.
- installation, 9.27.5. , 9.27.10.3. , 9.27.10.4.
- material standards, 9.27.10.1.
Siding, plywood, 9.27.8.
Siding, vinyl, 9.27.12.
- installation, 9.27.5. , 9.27.12.2.
- material standards, 5.10.1.1. , 9.27.12.1.
- Siding, waferboard (see Siding, OSB and waferboard)
Signs, 3.15.
- barrier-free accessibility, 3.8. , 3.8.3.1. , 3.8.3.3.
- directional, 3.4.5.1. , 9.9.11.3.
- egress points, 3.3.1.25.
- elevator to accommodate stretcher (indicating), 3.5.4.1.
- emergency crossover access to floor areas, 3.4.6.18.
- exit obstruction prevention, 3.4.6.11. , 9.9.11.2.
- exits, 3.4.5.1. , 9.9.11. , 9.9.11.3.
- floor numbering, 3.4.6.18. , 3.5.4.2. , 9.9.11.5.
- graphical symbols, 3.4.5.3.
- means of egress, 3.4.5. , 3.4.6.15. , 9.9.11.
- occupant load, 3.1.17.1.
- public pools, 3.11.3.1.
- public spas, 3.12.5.1.
- revolving door, 3.4.6.15.
- roof, (clearance around), 3.2.5.3.
- service space, (in), 3.3.1.25.
- shelf and rack systems, 3.16.1.4.
- stairs and ramps, 9.9.11.4.
- tactile signs, 3.4.5.2. , 3.4.6.16. , 3.4.6.18. , 3.8.3.18.
- visual information signs, 3.4.6.16. , 3.4.6.18. , 3.8.3.1. , 9.9.11.2.
- Silencing devices, 3.2.4.6. , 3.2.4.18. , 3.2.4.20. , 3.2.4.21. , 3.2.4.22. , 3.2.6.7. , 9.10.19.6.
Sill plates, 9.23.7.
Sinks
- Site stability, earthquake design, 4.1.8.17.
Size of
- ball, for test, 7.3.6.7.
- building drains, 7.4.9.4.
- building sewers, 7.4.9.4.
- cleanouts, 7.4.7.2.(1)
- definition, 1.4.1.2. [A]
- drainage pipes, 7.4.9.
- fixture outlet pipes, 7.4.9.3.
- interceptors, 7.4.4.3.
- leaders, 7.4.9.5.
- traps and trap arms, 7.5.1.1. , 7.5.6.3.
- vent pipes, 7.5.7.1.
- water distribution systems, 7.6.3.2.
- water service pipes, 7.6.1.1.
- water supply pipes, 7.6.3.
Skylights,
- area, 9.10.17.9.
- area calculations (inclusion in), 9.10.17.6.
- combustible, in corridors, 3.1.5.4. , 9.10.17.9.
- flame-spread rating, 3.1.13.2. , 9.10.17.1.
- glass standards, 9.6.1.3.
- in housing and small buildings, 9.7.
- installation, 9.7.6.
- manufactured and pre-assembled, 9.7.4.
- in noncombustible construction, 3.1.5.4.
- performance expectations, 9.7.3.
- requirements, 9.7.2.2.
- on roof adjacent to wall with windows, 3.2.3.15.
- site-built, 9.7.5.
- standards for, 5.10.1.1. , 9.7.4.2.
- thermal characteristics, 9.7.3.3.
- unsprinklered compartments (in), 3.2.3.15. , 9.10.12.2.
Slabs-on-ground (see also Floors-on-ground), 9.16.4.
- Sleepers, 9.30.1.3.
Sliding doors,
- Slip joints, 7.3.3.4.
Slip-resistance
- Slope of drainage pipes, 7.4.8.
Smoke
Smoke alarms,
- definition, 1.4.1.2. [A]
- in housing and small buildings, 9.10.19.
- interconnection, 9.10.19.5.
- location, 9.10.19.3.
- maintenance and care instructions, 9.10.19.7.
- power supply, 9.10.19.4.
- requirements, 3.2.4.20. , 9.10.19.1.
- silencing, 9.10.19.6.
- Smoke barrier doors, 3.2.3.20.
- Smoke barriers, 3.2.3.20. , 9.10.9.2. , 9.10.9.17.
Smoke chambers,
Smoke dampers
Smoke detectors
- air handling systems (in), 3.2.4.12. , 6.9.2.2. , 9.10.18.5.
- annunciators, 3.2.4.8.
- for construction camps, 9.10.21.7.
- definition, 1.4.1.2. [A]
- design and installation, 9.10.18.3.
- duct-type, 3.2.4.12.
- in electrical equipment rooms, 3.6.2.7.
- in elevators, 3.2.4.11. , 3.2.4.14.
- in fire alarm systems, 9.10.18.
- in lieu of smoke alarms, 3.2.4.20. , 3.2.4.21. , 9.10.19.4. , 9.10.19.8.
- and release of hold-open devices, 3.1.8.14.
- requirements, 3.2.4.11. , 9.10.18.4.
Smoke developed classification
- Smoke shafts, 3.2.6.6.
- Smoke stacks, 6.3.3.3.
- Snow accumulation, 4.1.6.2. , 4.1.6.3. , 4.1.6.7. , 4.1.6.10. , 5.6.2.2.
- arch roofs, 4.1.6.10.
- areas adjacent to roof projections, 4.1.6.7.
- basic load factors, 4.1.6.2. , 9.4.2.2.
- curved roofs, 4.1.6.10.
- domes, 4.1.6.10.
- due to sliding, 4.1.6.11.
- exterior platforms, 9.4.2.3.
- full and partial, 4.1.6.3.
- gable roofs, 4.1.6.9.
- and gap between roof and higher roof, 4.1.6.6.
- multi-level roofs, 4.1.6.5. , 9.4.2.2.
- snow drift at roof corners, 4.1.6.8. , 4.1.6.13.
- specified, 4.1.6.2. , 9.4.2.2.
- and structural design, 4.1.6.
- valleys in curved or sloped roofs, 4.1.6.12.
- weight calculations for drifts, 4.1.6.13.
- Snow removal, 4.1.6.14.
Soffits
- protection, 3.2.3.6. , 3.2.3.16. , 9.10.12.4. , 9.10.14. , 9.10.14.5. , 9.10.15.5.
- venting, 9.19.1.2. , 9.19.1.3. , 9.25.2.4.
Soil gas control
Soil, pyritic
Soil, 1.4.1.2. [A]
- bearing pressure, 9.4.4.1. - 9.4.4.3.
- design properties, 4.2.4. , 9.4.4.
- erosion control, 5.6.2.2.
- excavations, 4.2.5. , 9.12.
- foundation considerations, 4.2.4. , 9.4.4.
- footings and foundations (beneath), 9.12.2.2. , 9.12.4.1. , 9.15.1.1. , 9.15.3.2.
- identification and classification, 4.2.4.3. , 9.4.4.
- subsurface investigation, 4.2.4.1. , 4.2.4.2.
- swelling and shrinking, 4.2.4.11. , 9.4.4.4. 9.12.3.3. , 9.14.2.1. , 9.14.4.1. , 9.15.3.2. , 9.16.2.2.
- temperature, 5.2.1.1. , 5.2.1.3. , 9.12.2.2. , 9.16.2.2.
Soil or waste pipes
Soil or waste stacks
- Soil pipe, cast iron, 7.2.6.1. , 7.3.3.3. , 7.3.4.5.
- Solar heating, 7.6.1.13.
- Solar collector, 3.1.5.28. , 5.6.2.3.
Solar panels
- Solder, wiping, 7.2.9.2.
- Soldered joint, 7.3.2.4.
- Solder-joint fittings, 7.2.7.5. , 7.2.7.6. , 7.2.9.2.
Solid-fuel burning appliances
- Solid masonry, 1.4.1.2. [A]
- Solid masonry units, 1.4.1.2. [A], 9.15.5.1.
- Solvent cement, transition, 7.2.5.7. , 7.2.5.11.
Sound
- control, 3.3.4.6. , 5.9. , 9.11.
- protection from, 3.3.4.6. , 5.1.1.1. , 5.8.1. , 9.11.
- rating for fans, 9.32.3.10.
- smoke alarms, 9.10.19.2.
- resistance rating of walls, floors and ceilings, 9.11.1.1.
Sound transmission class (STC)
- Space heaters, 1.4.1.2. [A], 9.33.5.3.
- Space heating appliances, 1.4.1.2. [A], 9.33.5.3.
Spans, 9.23.4.
- Spatial separation between buildings, 3.2.3. , 9.10.14. , 9.10.15.
- Special structure, 3.2.2.2.
- Special washrooms, 3.8.3.12.
- Sprinkler protected glazed wall assembly, 1.2.1.1. [C], 3.1.8.20.
Sprinkler systems, (see also Automatic sprinkler systems) 3.2.2.18. , 3.2.5.12. , 9.10.1.3. , 9.10.18.4.
Sprinklered buildings or spaces, 9.10.9.15. , 9.10.9.16. , 9.10.9.17. , 9.10.10.6.
- fire-resistance rating, 9.10.8.2. , 9.10.9.15. , 9.10.10.6.
- fire separations, 3.3.1.4. , 3.6.2.5. , 9.10.9.15. , 9.10.9.16. , 9.10.9.17. , 9.10.10.6.
- heat and smoke detection, 9.10.18.4.
- in lieu of roof rating, 9.10.8.2.
- lobbies, 3.4.4.2. , 9.9.8.5.
- openings in exposing building faces, 3.2.3.1. , 9.10.14.4. 9.10.15.4.
- openings in fire separations, 3.1.8.6. , 9.10.13.8.
- and safety within floor areas, 3.3.
- service spaces, 3.6.
- soffit protection, 9.10.12.4.
- travel distance, 3.4.2.4. , 3.4.2.5. , 9.9.8.1. , 9.9.8.2. , 9.9.8.6.
- Sprinklered, definition, 1.4.1.2. [A]
Sprinkler systems
- for arena-type buildings, 3.1.2.3.
- for assembly occupancy (Group A, Division 1), 3.2.2.20. 3.2.2.21. , 3.2.2.22.
- for assembly occupancy (Group A, Division 2), 3.2.2.23. , 3.2.2.24. , 3.2.2.26. , 3.2.2.27. , 3.2.2.93.
- for assembly occupancy (Group A, Division 3), 3.2.2.29. , 3.2.2.31. , 3.2.2.33.
- for assembly occupancy (Group A, Division 4), 3.2.2.35.
- for barrier-free floor areas, 3.3.1.7.
- for basements, 3.2.1.5.
- for business and personal services occupancy (Group D), 3.2.2.56. , 3.2.2.57. , 3.2.2.59. , 3.2.2.60. , 3.2.2.61. , 3.2.2.63. , 3.2.2.65. , 3.2.2.93.
- for care, treatment or detention occupancy (Group B, Division 1), 3.2.2.36. , 3.2.2.37.
- for care, treatment or detention occupancy (Group B, Division 2), 3.2.2.38. - 3.2.2.41.
- for care, treatment or detention occupancy (Group B, Division 3), 3.2.2.42. - 3.2.2.46. , 3.2.2.93.
- combustible pipes in, 3.1.9.4. , 3.2.5.13. , 9.10.9.6. , 9.10.9.9.
- construction of, 3.2.5.12.
- for contained use areas, 3.3.3.7.
- and controlled egress, 3.4.6.17.
- for corridors, 3.1.13.6. , 3.3.2.6.
- design, 3.2.5.12.
- and door hold-open devices, 3.1.8.14.
- and egress doorways, 3.3.1.5.
- electrical supervision, 3.2.4.9.
- exceptions for mezzanines, 3.2.8.2.
- for exposing building face, 3.2.3.2.
- and fire alarm systems, 3.2.4.1. , 3.2.4.7. , 3.2.4.8. , 9.10.18.4.
- fire department connection, 3.2.5.15.
- and firefighting access, 3.2.5.1.
- fire hose connections, 3.2.5.10.
- fire hose stations, 3.2.5.11.
- fire separations in residential occupancy, 3.3.4.2.
- flame-spread rating, 3.1.13.8.
- for garages, 3.2.1.2. , 3.3.5.4. , 3.3.5.7.
- in heavy timber construction, 3.1.4.7. , 3.2.2.16.
- for high buildings, 3.1.13.7.
- for high-hazard industrial occupancy (Group F, Division 1), 3.2.2.72. - 3.2.2.74.
- for impeded egress areas, 3.2.2.19.
- installation, 3.2.5.12. , 9.10.1.3.
- for interconnected floor space, 3.2.8.3.
- for libraries, 3.3.2.13.
- in lieu of fire detectors, 3.2.4.10.
- limiting distance, 3.2.3.1.
- for low-hazard industrial occupancy (Group F, Division 3), 3.2.2.82. , 3.2.2.84. , 3.2.2.86. , 3.2.2.88. , 3.2.2.90. , 3.2.2.93.
- for medium-hazard industrial occupancy (Group F Division 2), 3.2.2.76. , 3.2.2.77. , 3.2.2.79. , 3.2.2.81. , 3.2.2.93.
- for mercantile occupancy (Group E), 3.2.2.66. , 3.2.2.67. , 3.2.2.69. , 3.2.2.71. , 3.2.2.93.
- and metal roof deck, 3.1.14.2.
- in noncombustible construction, 3.1.5.19.
- for repair garages, 3.3.5.4.
- required, 3.2.2.18.
- for residential occupancy (Group C), 3.2.2.47. - 3.2.2.49. , 3.2.2.51. , 3.2.2.52. , 3.2.2.55. , 3.2.2.93.
- for retirement homes (Group C), 3.2.2.55A. - 3.2.2.55E.
- and separation of public corridors, 3.3.1.4.
- and separation of suites, 3.3.1.1.
- and service penetrations, 3.1.9.4.
- for service spaces, 3.2.5.14.
- and soffit protection, 3.2.3.16.
- stages, 3.3.2.14.
- and standpipes, 3.2.5.8. , 3.2.5.9.
- for storage garages, 3.2.1.2. , 3.3.5.4. , 3.3.5.7.
- for storage rooms, 3.3.4.3.
- for storeys below ground, 3.2.2.15.
- system monitoring, 3.2.4.15.
- testing, 3.2.5.12.
- for theatres, 3.3.2.14.
- for underground walkways, 3.2.3.20.
- and unprotected openings, 3.2.3.1. , 3.2.3.12. , 3.2.3.14. , 3.2.3.15. , 3.2.3.17.
- Stability, structural, 4.1.3.2.
Stacks
- Stack, hydraulic load on, 7.4.10.6.
- Stack venting, 7.5.4.1.
Stack vents
- Stages (theatrical), 1.4.1.2. [A], 3.3.2.12. , 4.1.5.3. , 4.1.5.10.
- Stainless steel butt weld pipe fittings, 7.2.6.11.
- Stainless steel fixtures, 7.2.2.2.
- Stainless steel pipe, 7.2.6.10. , 7.2.6.15. , 7.3.4.3. , 7.3.4.5.
- Stainless steel pipe flanges, 7.2.6.12.
- Stainless steel threaded fittings, 7.2.6.13.
- Stainless steel tube, 7.2.6.14. , 7.2.6.15. , 7.3.4.5.
- Stainless steel welded joints, 7.3.2.8.
Stairs
- cantilevered, 9.8.9.2. , 9.8.10.
- clear height over, 9.8.2.2.
- concrete, 9.8.9.2. , 9.8.10.
- construction, 9.8.9.
- curved, 3.3.1.16. , 3.4.6.9. , 9.8.3. , 9.8.7.1.
- dimensions, 3.4.6. , 9.8.2. , 9.8.4.
- doors near, 3.4.6.11. , 9.9.6.6.
- in dwelling units, 3.3.4.4. , 3.3.4.7. , 9.8. , 9.9.9.
- exit signs with, 3.4.1.4. , 3.4.3.2. , 3.4.6. , 9.9.11.3. , 9.9.11.4.
- exterior, 9.8.9.2. , 9.8.9.3. , 9.9.2.6.
- finishes, 3.4.6.1. , 9.8.9.6.
- fire block required, 3.1.11.4. , 9.10.16.1.
- on fire escapes, 3.4.7.5.
- foundations, 9.8.9.2. , 9.12.2.2.
- guards, 3.4.6.6. , 9.8.8.1. - 9.8.8.7.
- handrails, 3.4.6.5. , 9.8.7. ,
- headroom, 3.4.3.5. , 9.8.2.2.
- height of, 9.8.3.3.
- landings, 3.4.3.5. , 3.4.6.4. , 9.8.6.
- loads on, 9.8.9.1.
- in noncombustible construction, 3.1.5.13.
- nosings, 3.3.2.5. , 3.4.6.8. , 9.8.4.8.
- permitted configurations, 9.8.3.1.
- in restaurants, 3.3.2.15.
- rise, 3.4.6.8. , 9.8.3.3. , 9.8.4.1. , 9.8.4.4.
- risers, 3.4.6.3. , 3.4.6.8. , 9.8.3.2. , 9.8.4.1.
- run, 3.4.6.8. , 9.8.4.2. , 9.8.4.3.
- slip-resistance, 3.4.6.1. , 9.8.9.6.
- spiral, 3.3.1.16. , 9.8.3.1. , 9.8.4.7.
- treads, 3.4.6.8. , 9.8.4.2. , 9.8.4.3. , 9.8.4.4. , 9.8.9.5.
- vertical rise, 3.4.6.3. , 9.8.3.3.
- width, 9.8.2.1.
- winders, 9.8.4.6.
- wood, 9.8.9.3. - 9.8.9.5.
Stairways
- as exits, 3.2.3.13. , 3.4.1.4. , 3.4.1.11. , 3.4.2.3. , 3.4.3.3. , 3.4.6.6. , 9.9.2.2. , 9.9.4.7.
- headroom clearance, 3.4.3.4. , 9.8.2.2.
- landings, 3.4.3.3.
- lighting, 3.2.7.1. , 9.9.12.2. , 9.34.2.3.
- in means of egress, 9.9.1.1.
- mezzanine egress, 9.9.8.6.
- projections into, 9.8.7.6.
- requirements, 3.3.1.14.
- roof-top enclosures, 3.2.2.14.
- weather protection, 3.3.5.4. , 3.4.6.11.
- width, 3.4.3.2. , 3.4.3.3. , 9.8.2.1.
- Standards, materials, 1.5. [A], 5.9.1.1.
Standpipe systems
Staples
Stapling
- asphalt shingles, 9.26.7.4. , 9.26.7.6. , 9.26.8.5.
- cladding, 9.27.5.4. , 9.27.7.3.
- plywood finish, 9.29.6.3.
- roofing, 9.26.7.4. , 9.26.7.6. , 9.26.8.5. , 9.26.9.5.
- sheathing membrane, 9.23.3.5.
- shingles, 9.26.7.4. , 9.26.7.6. , 9.26.8.5.
- siding, 9.27.5.4. , 9.27.7.3.
- subflooring, 9.23.3.5.
- underlay, 9.30.2.3.
- wood frame construction, 9.23.3.
- wood shingles and shakes, 9.26.9.5.
- wood strip flooring, 9.30.3.4.
- Static pressure, 7.6.3.3. , 7.7.1.1. , 7.7.2.4.
- Static procedure, wind load calculations, 4.1.7.3.
Steel
- beams, 9.23.4.3. , 9.23.8.2.
- cold-formed, structural design basis, 4.3.4.2.
- columns, 3.2.3.9. , 9.10.14.5. , 9.10.15.5. , 9.17.3.
- design, 9.4.1.1.
- design basis, 4.3.4.
- fire protection, 3.2.2.3. , 9.10.7.
- flashing, 9.20.13.1. , 9.27.3.1.
- in foundations, high-strength tendons in, 4.2.3.9.
- framing, 9.24.
- foundations (in), 4.2.3.7. - 4.2.3.10.
- lintels, 9.20.5.2. , 9.22.1.2.
- protection from corrosion, 4.2.3.10. , 5.1.4.2. , 9.3.3.2. , 9.17.3.3. , 9.20.5.2. , 9.20.16. , 9.23.8.2.
- roofing, 5.10.1.1. , 9.26.13.1.
- runners, 9.24.1.2. , 9.24.1.3. , 9.24.2.3. , 9.24.2.4. , 9.24.3.1. , 9.24.3.2. , 9.24.3.6.
- siding, 5.10.1.1. , 9.27.11.1.
- studs, (see Studs)
Steel pipe,
Stone, 9.20.2.5.
- Stop-and-waste cocks, 7.6.1.9.
Storage
- Storage areas, theatres, 3.3.2.14.
Storage bins
Storage buildings, self-service
Storage garages, 1.4.1.2. [A], 3.1.10.3. , 3.2.1.2. , 3.2.2.82. , 3.2.2.92. , 3.2.2.93. , 3.2.3.10. , 3.2.4.1. , 3.2.8.2. , 3.3.1.8. , 3.3.4.2. , 3.3.5.4. , 3.3.5.6. , 3.3.5.7. , 3.4.2.5. , 3.6.2.1. , 9.10.2.1. , 9.10.4.3. , 9.10.17.10. , 9.10.18.8.
- access through vestibule, 3.3.5.7.
- in basements, 9.10.4.3.
- in buildings with superimposed major occupancies, 3.2.2.7.
- carbon monoxide alarms, 6.9.3.1. , 9.33.3.9. , 9.32.3.9A. , 9.32.3.9B. , 9.32.3.9C
- cladding, 9.10.14.5. , 9.10.15.5.
- construction, 9.35.
- design, 4.4.2.1.
- doors, 9.7.5.2. , 9.9.6.4. , 9.10.17.10.
- exhaust into, 6.3.2.10.
- exposing building face, 3.2.3.10. , 9.10.14.4. , 9.10.14.5.
- fire alarms, 3.2.4.1. , 9.10.18.8.
- fire separations, 3.3.5.6. , 9.10.9.18.
- headroom clearance, 3.3.1.8.
- height, 3.3.5.4. , 9.5.3.3. , 9.9.3.4.
- height, 3.3.5.4. , 9.5.3.3. , 9.9.3.4.
- interconnection of ducting, 9.33.6.7. , 9.33.6.11.
- limiting distance, 3.2.3.1. , 3.2.3.10. , 9.10.14.4.
- in low-hazard industrial occupancies (Group F, Division 3), 3.2.2.92. , 3.2.2.93.
- open-air, 9.10.14.4. , 9.10.18.8.
- openings for vehicular ramps, 3.2.8.2.
- pressure less than in adjoining occupancies, 6.3.1.3.
- as separate buildings, 3.2.1.2.
- standpipes requirement, 3.2.5.9.
- unprotected openings in, 3.2.3.10. , 9.10.14.4.
- ventilation, 3.3.5.4. , 6.3.1.3. , 9.32.1.1.
- Storage lockers, 3.1.5.14. , 3.3.4.3.
- Storage racks, design, 4.1.8.18. , 4.4.3.1.
Storage rooms, 3.1.5.17. , 3.2.4.10. , 3.2.7.1. , 3.3.2.16. , 3.3.4.3. , 3.3.6.3. - 3.3.6.5. , 3.4.4.4. , 9.9.5.9. , 9.9.8.5. , 9.34.2.5.
- fire detectors, 9.10.18.3. , 9.10.18.5.
- fire separations, 3.3.4.3. , 3.6.2.5. , 9.10.10.6.
- Storage tanks, 2.3.2.5.
- Storage-type service water heaters, 1.4.1.2. [A], 7.6.1.12. , 9.31.6.1A. , 9.31.6.2 , 9.31.6.3.
Storeys, 1.4.1.2. [A], 3.2.1.1. , 9.5.2.2.
- below ground, 3.2.2.15.
- open-air, 3.2.1.5. , 3.2.2.82. , 3.2.2.92. , 3.2.3.10. , 3.2.5.4. , 6.3.1.3. , 9.10.14.4. , 9.10.18.8.
- sprinkler system requirements, 3.2.2.18.
Storm building drains or sewers (see Building drains
- Building sewers)
- definition, 1.4.1.2. [A]
Storm drainage systems
- Storm sewers, 1.4.1.2. [A], 7.1.2.2.
- Storm water, 1.4.1.2. [A], 7.1.2.2. , 7.4.2.1. , 7.4.6.1. , 7.7.2.
Stoves
- clearances, 9.10.22.
- definition, 1.4.1.2. [A]
- design and installation standard, 9.33.5.3. , 9.33.5.4.
- hearth-mounted, 9.22.10.
- installation, 9.10.22.1. - 9.10.22.3.
- Strandboard (see OSB)
- Strapping floor joists, 9.23.9.4.
- Strapping, floor joists, 9.23.3.4. , 9.23.9.3. , 9.23.9.4
Streets, 1.4.1.2. [A], 3.2.2.10. , 3.2.3.10. , 3.2.4.9. , 3.2.5. , 9.10.14.2. , 9.10.20.
- exposing building face on, 9.10.14.4. , 9.10.15.4.
- fire access routes, 3.2.2.10.
- unprotected openings facing, 3.2.3.10.
- Stress reversal, 4.1.3.2.
Structural design, Part 4, 9.4.
- Structural drawings, 4.1.5.8.
- Structural fire protection, 3.2.2.3. , 3.2.2.20. - 3.2.2.93. , 3.2.3.9. , 9.10.8.
- Structural loads and procedures, 4.1. , 5.2.2. , 5.9.3.2. , 9.4.
Structural movement
- Structures, special, (see special structures)
- Stubs, lead water closet, 7.3.3.8. , 7.4.2.1. , 7.3.3.6.
Stucco, 9.28.
- aggregate for, 9.28.2.2. , 9.28.5.1.
- application, 9.28.6.
- fasteners, 9.28.3.1. , 9.28.3.2.
- flashing for, 9.28.1.5.
- ground clearance, 9.28.1.4.
- for housing and small buildings, 9.28.
- installation, 9.28.1.2. , 9.28.1.3. , 9.28.3.1. , 9.28.3.2.
- lath, 9.28.4.
- material, 9.28.2.1. , 9.28.2.5.
- mixes, 9.28.5.1.
- mixing, 9.28.5.3.
- nails for, 9.28.3.2.
- pigments, 9.28.5.2.
- sheathing beneath, 9.27.3. , 9.28.1.1. , 9.28.4.2.
- sheathing membrane beneath
- staples, 9.28.3.2.
- staples for, 9.28.3.
- thickness, 9.28.6.
Studs, steel, 9.24.
- bracing and lateral support, 9.24.1.5.
- dimensions, 9.24.2.1. , 9.24.2.5.
- fastening, 9.24.3.6.
- fire-rated walls (in), 9.24.3.2.
- in housing and small buildings, 9.24.
- metal thickness, 9.24.1.3. , 9.24.2.2. , 9.24.2.4. , 9.24.2.5.
- notching and drilling, 9.23.5.3.
- openings (at), 9.24.2.4. , 9.24.3.5. , 9.24.3.7.
- orientation, 9.24.3.3.
- size and spacing, 9.24.2.1. , 9.24.2.5.
- standard for, 9.24.1.2.
Studs, wood, 9.23.10.
- bracing, 9.23.10.2.
- continuity, 9.23.10.4.
- at corners and intersections, 9.23.10.5.
- dimensions, 9.23.10.1.
- lateral support, 9.23.10.2.
- lumber grade, 9.3.2.1.
- notching and drilling, 9.23.5.3.
- openings (at), 9.23.10.6.
- orientation, 9.23.10.3.
- size, 9.23.10.1.
- spacing, 9.23.10.1.
Subflooring, 9.23.15.
- depressurization, 9.13.4. , 9.13.4.3.
- direction of installation, 9.23.15.4.
- edge support, 9.23.15.3.
- installation, 9.23.15.4.
- lumber, 9.23.15.7.
- materials, 9.23.15.2.
- nailing, 9.23.15.6.
- thickness, 9.23.15.5.
- wood-frame construction, 9.23.15.
Subsoil drainage pipes
- connection of, 7.4.5.3. , 7.4.6.4.(5)
- definition, 1.4.1.2. [A]
- sumps, 7.4.6.3.
- Subsurface investigation, 1.4.1.2. [A], 4.2.2. , 4.2.4.2. , 9.4.4.1. , 9.4.4.2.
- Suds pressure zones, 7.4.2.1.
Suites, separation, 3.3.1.1. , 9.10.9.13. , 9.10.9.15. , 9.10.9.16.
- definition, 1.4.1.2. [A]
- doors and door hardware, 3.3.1.13.
- fire separations, 9.10.9.15. , 9.10.9.16.
- separation of, 3.3.1.1.
- smoke control measures, 3.2.6.2.
- Supervisory signal, 3.2.4.9. , 3.2.6.7. , 3.2.9.5.
Supply
- capacity, 9.32.2.1. , 9.33.3.3. , 9.32.3.7. , 9.32.3.8.
- diffusers, 9.32.3.7. , 9.33.6.10A.
- ducts, 1.4.1.2. [A], 6.3.2.6A. , 9.32.3.4. - 9.32.3.6. , 9.32.3.11. , 9.32.3.12.
- fans, 9.32.3.10.
- outlets, 6.3.2.9. , 9.32.3.7. , 9.33.6.10A. , 9.33.6.11. , 9.33.10.1.
- systems, 9.32.3.4. - 9.32.3.6.
- Supply and waste fittings, 7.2.10.6.
Support
Surface temperature
T
- T fittings, 7.2.4.1. , 7.2.4.2.
- Tablet arms, 3.3.2.4.
- Tanks (drainage), 7.4.6.3.
- Tank-type water closets, 7.6.2.11.
- Tape for joints in air duct systems, 6.3.2.19. , 9.33.6.3.
- Tee joints, extracted, 7.3.3.2. .
- Telephones, 3.2.4.22. , 3.2.6.7. , 3.8.3.15.
Temperature
- indoor control, 12.3.1.3.
- indoor design, 5.2.1.2. , 5.3.1.2. , 5.5.1.2 , 6.2.1.1A. , 9.33.3.1.
- outdoor design, 1.1.3.1. , 5.2.1.1. , 5.3.1.2. , 5.5.1.2. , 6.2.1.2. , 9.33.3.2.
- pipes (of), 6.7.1.4. , 9.33.8.2.
- radiators (of), 6.7.1.3. , 9.33.8.2.
- soils, 5.2.1.1. , 5.2.1.3. , 9.12.2.2. , 9.16.2.2.
- supply air, 9.33.6.11
- transfer calculations, 5.2.1.3.
- Temperature controls, 7.2.10.7. , 7.6.1.7. , 7.6.1.12.
Temperature relief valves specifications for, 7.2.10.11.
- where required, 7.6.1.12.(2)
- Tempering of make-up air, 6.3.2.8. , 9.32.3.4. , 9.32.3.5 , 9.32.3.8. , 9.32.3.11.
Tents, 3.14.1.
- Terminals vent pipe, 7.5.6.5. , 7.5.9.1.
- Termites, protection against, 4.3.1.3. , 9.3.2.9. , 9.12.1.1. , 9.15.5.1. , 9.17.4.4.
Testing of
Tests, 2.1.1.2. [C]
- automatic sprinkler systems, 3.2.5.12.
- building fire safety, 3.2.9.1. , 9.10.18.10. , 9.10.19.8.
- fire-protection rating, 3.1.8.4. , 9.10.3.1.
- fire-resistance rating, 3.1.7.1. , 9.10.3.1. , 9.33.6.3.
- fire block, 3.1.11.7. , 9.10.16.3.
- fire stop systems, 3.1.9.1 , 3.1.11.7.
- flame-spread rating, 3.1.12.1. , 3.1.13.4. , 9.10.3.2.
- load, 4.1.1.5. , 4.2.4.1. , 9.23.14.11.
- noncombustible materials, 3.1.5.1.
- vapor transmission, 9.13.2.2. , 9.25.4.2.
- roof coverings, 3.1.15.1.
- smoke developed classification, 3.1.12.1.
- smoke control, 3.2.6.9.
- smoke movement in high buildings, 3.2.6.9.
- sound transmission, 5.9.1.1. , 9.11.1.2.
- standpipe systems, 3.2.5.8.
- wires and cables, 3.1.4.3. , 3.1.5.21. , 3.1.5.25.
- Theatres, 1.4.1.2. [A], 3.3.2.14.
Thermal
Thermal barriers, 3.1.4.2.
- foamed plastic (for), 3.1.5.15. , 9.10.17.10.
- in noncombustible construction, 3.1.5.14. , 3.1.5.15.
- Thermal breaks, 5.9.2.4. , 9.7.3.3.
- Thermal bridging, 5.3.1.3. , 9.25.1. , 9.25.2. , 9.25.5.1.
- Thermal expansion of piping, 7.3.3.9. , 7.6.1.11.
- Thermal insulation systems, 6.5.
Thermal resistance
- Threaded cast iron drainage fittings, 7.2.6.3.
- Thrust block, 7.3.4.9.
- Ticket booths, 6.3.1.3.
Tile
Tile, drainage
Tile, floor, 9.30.6.
Tile, roof
Tile, wall, 9.29.10.
- installation, 9.29.10.1. - 9.29.10.4.
- moisture resistant backing, 9.29.10.4.
- Tire storage, 3.3.6.5. , 3.16.3.
- Top plates, walls, 9.23.5.4. , 9.23.11.4.
Towers
- Toxic gases, storage, 3.3.6.3.
- Trade shows, 3.1.2.3. , 3.2.2.29. , 3.2.2.30. , 3.2.2.32.
- Transformer vaults, 3.2.7.1. , 3.6.2.7. , 7.4.3.4. , 9.10.1.3.
- Transition solvent cement, 7.2.5.11.
- Transparent panels, 3.3.1.20. , 3.4.1.8. , 9.6.1.4. , 9.7.2.1.
- Transponder, for fire alarm, 3.2.7.10.
- Trap arms, 1.4.1.2. [A], 7.3.4.5. , 7.5.2.1. , 7.5.4.5. , 7.5.6.3.
- Trap dips, 1.4.1.2. [A], 7.4.7.1.
Traps
- bell, 7.2.3.1.
- cleanouts for, 7.2.3.1.(3) , 7.4.5.4.
- connections for, 7.2.3.1.(3)
- definition, 1.4.1.2. [A]
- design of, 7.2.3.1.
- drum, 7.2.3.1.(5)
- for fixtures, 7.4.5.1. , Table 7.4.9.3 .
- for floor drains, 7.4.5.2.
- interceptors, used as, 7.2.3.1. , 7.4.5.1.
- restricted locations, 7.4.3.2.
- for sanitary drainage systems, 7.4.4.4. , 7.4.5.1.
- for storm drainage systems, 7.4.5.2.
- for subsoil drains, 7.4.5.3.
- location of, 7.4.5.2. , 7.4.5.4.
- restricted locations, 7.4.3.2.
- seals, 7.4.5.5.
- size, 7.4.10.2. , 7.4.10.12. , 7.5.7.1.
- tubular, 7.2.3.3.
- venting of, 7.5.1.
- Trap seal depth, 1.4.1.2. [A], 7.2.3.1.
Trap seals
Trap standards
- Trap weirs, 1.4.1.2. [A], 7.3.3.4. , 7.4.9.3.
- Travel distance, (see also exits), 3.3.1.5. , 3.3.1.6. , 3.3.3.5. , 3.3.6.4. , 3.4.2.1. , 3.4.2.4. , 3.4.2.5. , 9.9.4.7. , 9.9.7.6. , 9.9.8.1. , 9.9.8.2. , 9.9.8.6.
Treads,
- dimensions, 3.3.1.16. , 3.4.6.8. , 9.8.4.
- finish, 9.8.9.6.
- mixed, 9.8.4.5.
- nosings, 9.8.4.8.
- rectangular, 9.8.3.1. , 9.8.4.1. , 9.8.4.2.
- slip-resistance, 3.4.6.1. , 9.8.9.6.
- tapered, 3.3.1.16. , 3.4.6.9. , 9.8.3.1. , 9.8.4.1. , 9.8.4.3. , 9.8.4.4.
- thickness, 9.8.9.5.
- uniformity and tolerances, 9.8.4.4.
- in winders, 9.8.4.6.
- wood, 9.8.9.5.
- Treatment of sewage and wastes, 7.4.4. , Part 8
- Trench, for piping of flammable liquids, 6.9.1.2.
- Trenchless technology, 7.2.5.5.
- Trim, for windows, doors and skylights, 9.7.6.2.
- Trouble signal, 3.2.4.8. , 3.2.4.9. , 3.16.1.16.
Trusses (see also Wood, design basis), 9.23.14.11.
- design, 9.4.2.2. , 9.4.2.4. , 9.23.14.11.
- lumber grade, 9.3.2.1.
- maximum deflections, 9.23.14.11.
- snow loads, 9.4.2.2.
Tube
- Tubing for pneumatic controls, 3.1.5.2.
- Turnstiles, 3.4.3.3. , 3.13.4.6. , 9.9.5.4. , 9.9.5.5.
Tying (see Anchorage)
- intersecting masonry walls, 9.20.11.2.
- masonry, 9.20.9.
- wood to masonry walls, 9.20.11.4.
U
- Underground ducts, 6.3.2.12. , 9.33.6.7.
Underground pipes
Underground walkways, 3.2.3.20. , 3.2.7.3. , 9.9.12.3.
- noncombustible finish, 3.1.13.9.
Underlay
- fastening, 9.30.2.3.
- flooring (beneath), 9.30.2.
- hardboard, 9.30.2.2.
- installation, 9.26.6.2. , 9.30.2.3. - 9.30.2.5.
- materials, 9.26.6.1. , 9.30.2.2. , 9.30.2.5.
- material standards, 9.30.2.2.
- nailing, 9.30.2.3.
- OSB, 9.30.2.2.
- particleboard, 9.30.2.2.
- plywood, 9.30.2.2.
- roofing, 9.26.6. , 9.26.10.2.
- shakes (beneath), 9.26.10.2.
- shingles (beneath), 9.26.6.
- stapling, 9.30.2.3.
- thickness, 9.30.2.2.
- Unit heaters, 1.4.1.2. [A], 6.4.2.
- Unions and slip joints, 7.3.3.4. , 7.4.6.3.(6)
Universal washrooms, 3.8.3.12.
- emergency lighting, 3.2.7.3.
Unprotected openings, (see also Exposing building face and Limiting distance), 1.4.1.2. [A], 3.2.3.1. , 3.2.3.7. , 3.2.3.10. , 3.2.3.12. , 3.2.3.14. , 9.9.4.6 , 9.10.12.3. , 9.10.14. , 9.10.15.
- in floors, 9.10.1.3.
- Unsafe conditions, 1.4.1.2. [A]
- Unstable liquids, 1.4.1.2. [A]
- Unusual structures, 3.2.2.2.
- Used materials, 7.2.1.2.
V
Vacuum breakers (see Back-siphonage preventers),
- definition, 1.4.1.2. [A], 7.2.10.11. , 7.6.1.7.
Vacuum cleaning systems, 3.2.4.13. , 9.10.18.7.
- penetrating fire separations, 9.10.9.6.
- suites served, 9.10.9.21.
- location, 7.4.3.1.
Valves
- accessibility, 7.1.3.2.
- air admittance, 1.4.1.2. [A], 7.2.10.16. , 7.5.9.
- automatic compensating, 7.2.10.6. , 7.2.10.7.
- backflow preventers, 1.4.1.2. [A], 7.2.10.10. , 7.6.1.11. , 7.6.2.1. , 7.6.2.2. , 7.7.2.4.
- backwater, 7.4.2.1. , 7.4.3.6. , 7.4.6.3. , 7.4.6.4. , 7.7.2.4.
- check, 7.2.11.4. , 7.4.2.1.(1) , 7.4.6.3.(6)
- direct flush, 7.2.10.8. , 7.4.9.3.
- manually operated, 7.2.10.6.
- pressure reducing, 7.6.1.11. , 7.6.3.3. , 7.7.1.1. , 7.7.2.4.
- pressure relief, 7.2.10.11. , 7.6.1.7.(1)(4)
- reducing, 7.2.10.12.
- shut-off, 7.4.6.3.(6) , 7.6.1.4.
- sprinkler, 3.2.4.9. , 3.2.5.12.
- tank-type water closet, 7.2.10.10.(2)
- temperature relief, 7.2.10.11. , 7.6.1.7.(2)(4)
- vacuum relief, 7.2.10.11.
Vapour
- Vapour pressure, 5.5.1.1. (see also Flammable liquids)
- Vault, 3.2.7.1. , 3.6.2.7. , 9.10.1.3.
Vehicle guardrails, 9.8.8.4.
- loads, 4.1.5.15.
Vehicular passageways, 3.2.3.18.
- flame-spread rating, 3.1.13.2.
- Vehicular ramp, 3.2.8.2. , 3.3.1.18. , 9.8.8.4.
Veneer
- flashing, 5.6.2.1. , 9.20.13.7.
- masonry, 5.6.1.2. , 5.10.1.1. , 9.20.6.4. 9.20.8.5. , 9.20.9.5. , 9.20.12.3.
- Vent connector, 1.4.1.2. [A]
- Vent headers, 1.4.1.2. [A], 7.5.1.1. , 7.5.7.2. , 7.5.8.3.
- Ventilating systems (see Heating, ventilating and air- conditioning systems and equipment)
Ventilation, 3.3.1.21. , 3.3.5.4. , 3.3.5.7. , 7.1.6.1.
- of air contaminants, 6.3.1.5.
- attic or roof spaces, 6.3.1.2. , 9.19.1.
- capacity, 9.32.3.3. - 9.32.3.5.
- crawl spaces, 6.3.1.2. , 9.18.3.
- crawl spaces, heated, 9.18.3.2.
- crawl spaces, unheated, 9.18.3.1.
- direct-vent, 9.32.3.6. , 9.32.3.8.
- dwelling units, 9.32.
- electrical equipment vaults, 3.6.2.7.
- exhaust, 3.3.1.21. , 9.10.9.20. , 9.32.3.3. , 9.32.3.6. , 9.32.3.13.
- exhaust ducts and outlets, 6.3.2.10.
- housing and small buildings, 9.32.
- laboratories, 6.3.4.
- mechanical, 3.3.1.21. , 6.3.1.1. , 6.3.1.3. , 6.3.1.5. , 6.9.1.2. , 9.32.1.2. , 9.32.3.
- natural, 6.3.1.1A. , 9.32.2.
- outlets, 9.32.3.6. , 9.32.3.13.
- parking garages, 9.32.1.1.
- requirements, 6.3.1.1. , 9.32.1.2. , 9.32.2.1. , 9.32.3.1.
- residential, 6.3.1.1.
- rooms, of, 7.1.3.1.
- secondary suites, 9.32.1.2. , 9.32.3.8. , 9.32.3.9.
- storage garages, 6.3.1.3. , 9.32.1.1.
- vaults, 3.6.2.7.
- windows for, 9.32.2.
Venting
- air space in building envelopes, 9.25.5.2. , 9.27.3.1. , 9.27.3.8.
- attic or roof spaces, 6.3.1.2. , 9.19.1.
- back, 7.5.6.1.
- chimneys, 9.21. , 9.33.10.1.
circuit,
- combustion products, 6.3.3.1. , 6.3.2.11. , 9.22.1.4. , 9.32.3.8. , 9.33.10.1.
- corrosive drain piping, 7.5.5.3
- crawl spaces, 6.3.1.2. , 9.18.3.
- crawl spaces, heated, 9.18.3.2.
- crawl spaces, unheated, 9.18.3.1.
- dilution tanks, 7.5.5.3. , 7.5.7.7.
- dual, 7.5.8.2.
- exceptions, 7.5.1.1.
- explosion and relief devices, 3.3.1.21. , 3.6.2.7.
- firefighting, 3.2.6.6.
- firefighting in high buildings, 3.2.6.6. , 3.2.6.9.
- floor drains, 7.5.1.1.
- heating appliances, 9.21. , 9.33.4.1. , 9.33.5.1. , 9.33.5.2. , 9.33.10.1.
- indoor storage of compressed gas, 3.3.6.3.
- interceptors, 7.5.5.2.
- laundry-drying equipment, 9.32.1.3.
- mansard roofs, 9.19.1.4.
- offsets, 7.5.4.4.
- sewage tanks, 7.5.5.1. , 7.5.7.7.
- sewage sumps, 7.5.5.1.
- soffits, 9.19.1.2. , 9.19.1.3. , 9.25.2.4.
stacks, 7.5.4.2.
- systems, testing of, 7.3.6.
trap to vent,
- wet, 7.5.2. , 7.5.8.1.
yoke, 7.5.4.3.
Vents
- additional circuit, 1.4.1.2. [A], 7.5.1.1. , 7.5.3.7. , 7.5.4.5. , 7.5.7.3. , 7.5.8.5.
- branch, 1.4.1.2. [A], 7.5.1.1. , 7.5.7.2. , 7.5.8.3.
- circuit, 1.4.1.2. [A], 7.5.1.1. , 7.5.3.1. , 7.5.4.5. , 7.5.7.3. , 7.5.8.3.
- continuous, 1.4.1.2. [A], 7.5.1.1. , 7.5.2.1. , 7.5.8.3.
- dual, 1.4.1.2. [A], 7.5.1.1. , 7.5.8.2. , 7.5.9.1.
- gas, 9.33.10.1.
- individual, 1.4.1.2. [A], 7.5.1.1. , 7.5.8.2. , 7.5.8.3. , 7.5.9.1.
- in stair shafts, 3.7.6.2.
- offset relief, 1.4.1.2. [A], 7.5.1.1. , 7.5.4.4. , 7.5.4.5. , 7.5.7.4. , 7.5.8.5.
- relief, 1.4.1.2. [A], 7.5.1.1. , 7.5.3.1. , 7.5.6.4. , 7.5.7.3. , 7.5.8.5.
- stack, 1.4.1.2. [A], 7.5.1.1. , 7.5.4.1. , 7.5.7.2. , 7.5.8.4.
- wet, 1.4.1.2. [A], 7.5.1.1. , 7.5.2.1. , 7.5.8.1.
- yoke, 1.4.1.2. [A], 7.5.1.1. , 7.5.4.3. , 7.5.4.5. , 7.5.7.5. , 7.5.8.5.
Venting systems
Vents for plumbing branch, 7.5.8.3.
- circuit, 7.5.3.1. , 7.5.7.3.
- combining, 7.5.3.1. , 7.5.6.5.
- connected above centre line, 7.5.6.2.
- connected above fixture, 7.5.6.4.
- continuous, 7.5.1.1. , 7.5.2.1. , 7.5.8.3.
- developed length measure, 7.5.8.3.
- extended outside, 7.5.4.1.
- header, 7.5.1.1. , 7.5.7.2. , 7.5.8.3.
- height above roof, 7.5.6.5.
- interceptors, 7.5.5.2.
- loading, Table 7.5.8.1 ., Table 7.5.8.3 ., Table 7.5.8.4 .
- location of, 7.5.6.3.
- manholes, 7.5.7.6.
- minimum size, 7.5.7.1. , 7.5.7.2.
- not required, 7.5.1.1.
- required for drain, 7.5.1.1.(2)
- sewage sumps, 7.5.5.1.(1)
- sizes for fixture tables, 7.5.7.1.
- stack, 7.5.4.1.
- terminals, distance from openings, 7.5.6.5.
- terminals, height above roof, 7.5.6.5.
- vent stack required, 7.5.4.2.
Vent pipes
- arrangement of, 7.5.6.
- cast-iron, 7.2.6.1.
- connections, 7.5.6.2.
- definition, 1.4.1.2. [A]
- for dilution tanks, 7.5.5.3. , 7.5.7.7.
- drainage, 7.5.6.1.
- fixture connections to, 7.5.2.1. , 7.5.3.1.
- flashing for, 7.2.10.14.
- for soil or waste stacks, 7.5.4.
- location of, 7.5.6.3.
- for macerating toilets, 7.5.7.7.
- for manholes, 7.5.7.6.
- minimum size of, 7.5.7.
- miscellaneous, 7.5.5.
- neutralizing tanks, 7.5.5.3. , 7.5.7.7.
- for sewage sumps, 7.5.7.7.
- sizing, 7.5.7. , 7.5.8.
- for stacks, 7.5.4.
- suds pressure zones, 7.4.2.1.
- not required, 7.5.1.1.
- size, 7.5.7.1.
- support of, above roof, 7.3.4.7.
- terminals, 7.5.6.5.
- for traps, 7.5.1.
Vent stacks
- Vertical piping, support of, 7.3.4.4.
Vertical service spaces, 1.4.1.2. [A], 3.2.8.1. , 3.5.3.2. , 3.5.3.3. , 3.6.1.1. , 3.6.3.1. , 3.6.3.4.
- flame-spread rating, 3.1.13.2.
Vestibule, 3.1.8.17. , 3.1.13.7. , 3.2.8.4. , 3.3.5.4. , 3.3.5.7. , 3.5.3.1. , 3.8.3.3.
- horizontal exits, 3.4.6.10.
Vibrations, 4.1.3.1. , 4.1.3.3. , 4.1.3.6. , 4.1.7.2. , 4.1.8.2. , 6.3.2.18.
- floors, 9.23.4.2.
- Visual disability, 3.3.1.9.
- Visible signal device, 3.2.4.19. , 3.2.4.21.
- Vitreous china fixtures, 7.2.2.2.
- Vitrified clay pipe and fittings, 7.2.5.4. , 7.3.5.2.
Voice communication systems, 3.2.4.22. , 3.2.4.23. , 3.2.6.7. , 3.2.6.8. , 3.2.7.8.
W
Waferboard
- cladding, 5.10.1.1. , 9.27.2.4. , 9.27.3.6. , 9.27.5. , 9.27.10.
- fire block materials, 3.1.11.7. , 9.10.12.4. , 9.10.16.3.
- fire protection of soffits, 9.10.12.4.
- firestops, 3.1.11.7.
- interior finish, 9.29.9.
- material, 9.3.2.4.
- material standard, 5.10.1.1. , 9.23.15.2. , 9.23.16.2. , 9.23.17.2. , 9.27.10.1. , 9.29.9.1. , 9.32.16.2.
- roof sheathing, 9.3.2.4. , 9.23.3.5. , 9.23.16. , 9.26.11.8.
- sheathing, 9.23.10.2.
- siding, 9.27.3.6. , 9.27.5. , 9.27.10.
- subflooring, 9.3.2.4. , 9.23.3.5. , 9.23.14.2. , 9.23.14.5. , 9.30.2.1.
- thickness, 9.3.2.7. , 9.23.16.7. , 9.29.9.2.
- tolerances, 9.3.2.7.
- underlay, 9.30.2.2.
- wall sheathing, 9.3.2.4. , 9.23.3.5. , 9.23.10.2. , 9.23.16.2. , 9.23.17.2. , 9.23.17.5.
- Walk-in coolers/freezers, 3.1.4.2. , 3.1.5.7. , 9.10.17.10.
Walks
Walkways, 1.4.1.2. [A]
- barrier-free path of travel, 3.8.1.3.
- between buildings, 3.2.3.19.
- construction camps, 9.10.21.5.
- exterior, 9.9.4.2. , 9.9.9.3. , 9.10.8.8. , 9.10.17.4.
- fire protection, 9.10.1.2. , 19.10.1.3.
- separation of buildings, 3.2.3.19.
- smoke detectors, 3.2.4.11.
- underground, 3.2.3.20.
- Wall membranes, 9.10.5.
Wall panels
- braced (see Braced wall panels)
- factory-assembled, 3.1.5.7.
- Wall plates, 9.23.3.4. , 9.23.11.
Walls
- air barrier systems, 9.25.3.
- anchorage, 9.20.11. , 9.23.3.4. , 9.35.4.3.
- bracing, 9.23.10.2. , 9.23.13.
- carports, 9.35.4.1. , 9.35.4.3.
- cladding, 9.27.
- exposed to adjoining roof, 3.2.3.15. , 9.10.12.2.
- exterior, at firewall, 3.1.10.6.
- exterior, exposed to another wall, 3.2.3.14. , 9.10.12.3.
- exterior, fire-resistance rating, 3.1.7.2. , 3.1.7.3. , 3.2.3.7.
- finish, 9.29.
- fire-resistance rating, 3.2.3.7. , 3.2.3.11. , 9.10.8.3. , 9.10.14.5. , 9.10.15.5.
- fire-resistance rating, exterior, 3.1.7.2. , 3.1.7.3. , 3.2.3.7. , 3.2.3.8. , 9.10.3. , 9.10.14.5. , 9.10.15.5.
- fire-resistance rating, interior, 3.1.7.3. , 9.10.3.
- fire-resistance rating, steel stud walls, 9.24.3.2.
- fire-resistance rating, walls, columns, arches, 3.1.7.5. , 9.10.8.3.
- fire blocks in, 9.10.16.2.
- firewalls, 1.4.1.2. [A], 3.1.10. , 4.1.5.17. , 9.10.11.
- foamed plastics in, 9.10.17.10.
- foundations, 4.2. , 9.15.4.
- framing, 9.23.10. - 9.23.13. , 9.24.
- garages, 3.3.4.2. , 9.10.9.16. , 9.35.4.1.
- as guards, 4.1.5.16.
- in health facilities, 3.3.3.5.
- height, 9.20.6. , 9.23.10.
- intersecting, anchorage, 9.20.11.
- lateral support, 9.20.10. , 9.23.10.2.
- loadbearing, 1.4.1.2. [A], 3.2.1.4. , 9.10.8.3. , 9.23.9.8. , 9.23.10.2. , 9.23.10.3. , 9.23.12.2. , 9.23.12.3. , 9.24.1.1.
- loads on, 4.1.10.3.
- masonry, 5.10.1.1. , 9.20.
- masonry veneer, 5.10.1.1. , 9.20.6.4.
- non-loadbearing, 9.23.12.1. , 9.24.
- openings in loadbearing, 9.23.12.2.
- openings in non-loadbearing, 9.23.9.6. , 9.23.10.4. , 9.23.10.6. , 9.23.12.1. , 9.23.14.3. , 9.24.2.4. , 9.24.3.1. , 9.24.3.5. - 9.24.3.7.
- parapets, 3.1.10.4. , 9.20.6.5.
- party wall, 1.4.1.2. [A], 9.10.11.1.
- plank frame, 9.3.2.1.
- post and beam, 9.3.2.1.
- in public corridors, 9.10.17.5.
- recesses, 9.20.7.
- retaining, 1.3.1.1. [A], 9.3.2.9. , 9.4.4.6.
- sheathing, 9.23.13. , 9.23.16 , 9.27.3.4. , 9.27.3.5.
- steel stud, 9.24.
- support on framed floors, 9.23.9.8.
- supports, 9.23.9.8.
- thermal insulation, 9.25.1.1. , 12.2.1.2.
- thickness, 9.20.6.
- wind loads, 4.1.7.5. , 4.1.7.6.
Walls, exterior
- in combustible construction, 3.1.4.8.
- enclosing attic or roof space, 3.2.3.3.
- exposed to another wall, 3.2.3.14. , 9.10.12.3.
- fire-resistance rating, 3.1.7.2. , 3.1.7.3. , 3.2.3.7. , 3.2.3.11. , 9.10.3.1. , 9.10.3.3. , 9.10.14.5. , 9.10.15.5.
- at firewall, 3.1.10.6.
- in noncombustible construction, 3.1.5.5. , 3.1.5.6.
- restrictions on combustible projections, 3.2.3.6. , 9.10.14.5. , 9.10.15.5.
- thickness, 9.20.6.1.
Walls, interior
- finish, 9.29.
- not fire separations, 9.10.12.3.
- thickness, 9.20.6.3.
- Wall studs (see Studs, steel; Studs, wood)
Warehouses
- Warm air outlets, 9.33.6.10. , 9.33.6.10A. , 9.33.6.11.
- Washers, 7.2.10.2. , 7.4.9.3. , 7.6.3.2. , 7.7.2.2.
- Washers, air, 6.2.3.14.
- Washing machines, 7.4.5.1. , 7.4.9.3. , 7.6.3.2.
- Wash fountains, circular, 3.7.2.3.
Washrooms, 3.8.3.12.
- Waste, cooling, 7.4.4.2.
- Waste pipe, lead, 7.2.7.8. , 7.3.4.5.(2)
- Waste, heated, 7.4.4.2.
- Waste, treatment of, 7.4.4.1. , Part 8.
Water
- accumulation, 3.1.19.1. , 5.6.2.2. , 5.7.1.1.
- bottle filling station, 3.8.3.16A.
- drainage, 5.6.2.2. , 5.8.1. , 9.14.
- drainage disposal, 9.14.5.
- drinking, 3.7.4.17. , 7.2.10.9. , 7.6.
- excavations (in), 4.2.5.5. , 9.12.1.2.
- flooring resistant to, 9.30.1.2.
- ingress, 5.7.1.1.
- permeance, 5.8.2.2.
- protection, 5.8.2.
- protection against, application of Code, 9.13.1.1.
- protection against, in exterior insulation finish systems, 5.9.4.1.
- protection against, in fenestration, 5.9.3.5.
- protection against hydrostatic pressure, 5.7.2.
- protection from groundwater, 5.7.3.
- resistant backing for wall tile, 9.29.10.4.
- resistant flooring, 9.30.1.2.
- required protection against, 5.7.1.2.
- surface, 3.1.19. , 5.7. , 5.7.1.1.
- temperature, 3.7.6.5. , 7.6.5.1. , 9.31.6.1A.
- Water closets, 3.7.4.2. , 3.7.4.12. , 3.7.4.14. , 3.7.6.3. , 3.8.3.8. , 3.8.3.9. , 9.31.4.1.
- Water closets, installation of, 7.2.10.2. , 7.3.3.8.
- Water closet bowls
Water coolers, 7.6.3.2.
Water distribution systems
- Water efficiency, 7.6.4. , 12.4.
- Water flow rates, 7.2.10.6.
- Water hammer arresters, 7.2.10.15.
- Water hammer, prevention of, 7.6.1.14. , 7.6.1.9.
Water heaters
Water pipe
- Water pressure tests, 7.3.6.1. - 7.3.6.4. , 7.3.7.1. - 7.3.7.3.
Water service pipe
Water supply, 3.2.7.9. , 3.7.4.1. , 7.6.3.1. , 7.6.3.2. , 9.31.3. , 9.31.4.3.
- Water tests, 7.3.6.4. , 7.3.7.3.
- Water temperature control, 7.2.10.7.
- Water treatment device, 7.2.10.17. , 7.4.2.1.
- Waterflow detecting devices, 3.2.4.9. , 3.2.4.15. , 3.2.5.14.
- Waterproof interior wall finish, 9.29.2.
Waterproofing
- criteria, 5.8.2.2. , 9.13.3.
- floors-on-ground, 5.8.2. , 9.13.3.6. , 9.16.1.4.
- installation, 5.6.1.2. , 9.13.3.
- installation standards, 5.8.2.3. , 9.13.3.3. , 9.26.15.1
- material standards, 5.10.1.1 , 9.13.3.2. , 9.26.2.1.
- preparation of surface, 9.13.3.3.
- protection from groundwater, 5.7.3.3.
- requirement for, 5.8.2.1. , 9.13.3.1.
- roofs, 5.6.1.2. , 9.13.3.1. , 9.26.2.1.
- walls, 9.13.3.1. , 9.13.3.3. , 9.13.3.4.
- Water usage per flush cycle, 7.6.1.6.
- Weep holes, 9.20.13.5. , 9.20.13.6. , 9.20.13.8.
- Welded and seamless steel pipe, 7.2.6.7.
Welded joints, 7.3.3.3.
- stainless steel, 7.3.2.8.
- Welding and cutting, 3.3.1.26.
- Welded and seamless steel pipe, 7.2.6.7.
- Welding operations room, 3.3.1.26.
Wells
Wet venting, 7.5.1.1. , 7.5.2. , 7.5.8.1.
- definition, 1.4.1.2. [A]
- Wheelchair spaces and path of travel, 3.8.2.1.
Wind loads, 4.1.7. , 5.1.4.1. , 5.2.2.1.
- and air barrier systems, 9.25.3.2.
- anchorage of building frames, 9.23.6.1.
- bracing to resist, 9.23.13.
- calculation of, 5.2.1.3. , 5.2.2.2.
- dynamic effects, 4.1.7.2.
- dynamic procedure, 4.1.7.8.
- exterior ornamentations, equipment an appendages, 4.1.7.11.
- external pressure coefficients, 4.1.7.5.
- external pressure coefficients, low buildings, 4.1.7.6.
- fasteners for sheathing or subflooring, 9.23.3.5.
- full and partial, 4.1.7.3.
- interior walls and partitions, 4.1.7.10.
- internal pressure coefficient, 4.1.7.7.
- pressure differences due to, 4.1.7.10. , 4.1.7.4.
- roof sheathing, 9.23.16.1.
- specified, 4.1.7.1.
- static procedure, 4.1.7.3.
- and structural design, 4.1.7.
- structural strength, 9.4.1.1. , 9.6.1.3.
- topographic factor, 4.1.7.4. , 9.6.1.3.
- wind tunnel procedure, 4.1.7.14.
- Winders, 9.8.4.6.
Windows, (see also glass, wired glass) 3.1.8.5. , 3.7.2.1. , 9.7. , 12.2.1.2. , 12.3.1.2.
- access for firefighting, 9.10.20.1.
- access to exit, 3.3.1.17. , 9.9.
- airtightness, 5.10.2.3. , 9.7.4.
- barriers or railings with, 3.3.1.18.
- bedrooms, 9.9.10.1.
- caulking and sealing, 9.7.4. , 9.20.13.11. , 9.27.4.1.
- cleaning (anchors for), 4.4.4.1.
- as closures, 3.1.8.5.
- dimensions, 9.32.2.2.
- energy rating, 12.2.1.2. , 12.3.1.2.
- exits, 3.2.3.13. , 9.9.4.5. , 9.9.9.1.
- exposing building faces (in), 3.2.3.1. , 3.2.3.15. , 9.10.14. , 9.10.15.
- flashing, 9.20.13.3. , 9.20.13.4. , 9.20.13.12. , 9.27.3.8.
- fire separations, (in), 3.1.8.4. , 3.1.8.5. , 3.1.8.16.
- firefighting access, 3.2.5.2. , 3.2.5.3. , 9.10.20.1. , 9.10.20.2.
- frames, combustible, 3.1.5.4. , 3.1.5.7.
- glass area, 3.7.2.1. , 9.10.14.4. , 9.10.15.4.
- glass thickness, 4.3.6.1. , 9.6.1.3.
- for housing and small buildings, 9.7.
- installation, 9.7.6.
- manufactured and pre-assembled, 9.7.4.
- as means of egress, 9.7.2.2.
- for natural ventilation, 9.32.2.2.
- in noncombustible construction, 3.1.5.4.
- not a means of egress, 9.9.2.3.
- opening into window wells, 9.9.10.1.
- openings, 9.8.8.1. , 9.9.10.1.
- performance expectations, 9.7.2.
- protection in exits, 3.4.6.6. , 9.6.1.4.
- protection in public areas, 9.8.8.1.
- protection in residential occupancy, 3.3.4.8. , 9.8.8.1.
- public spaces (in), 9.7.5.
- requirements, 9.7.2.2.
- resistance to forced entry, 3.3.4.10. , 9.7.5.3.
- sills, 9.20.13.12. , 9.27.3.8.
- site-built, 9.7.5.
- soffit protection (for), 3.2.3.16. , 9.10.12.4.
- structural design, 4.3.6.1.
- standard for, 5.10.1.1. , 9.7.4.
- thermal breaks, 5.3.1.2. , 9.7.3.3.
- thermal transmittance (U-value), 9.7.3.3. , 12.2.1.2. , 12.3.1.2.
- unobstructed opening area, 9.9.10.1. , 9.32.2.2.
- venting to aid firefighting, 3.2.6.6.
- watertightness, 5.10.2.3. , 9.7.4.
- wind load resistance, 5.2.2.2. , 9.7.4.
- Window well, 9.9.10.1. , 9.14.6.3.
- Wind tunnel procedure, 4.1.7.14.
- Wiped joint, 7.3.2.2.
- Wired glass, 3.1.8.16. , 3.1.8.18. , 3.2.3.5. , 3.2.3.12. , 3.2.3.13. , 3.13.3.1. , 3.13.3.5. , 3.13.3.6. , 3.13.4.2. , 5.9.2.1. , 6.4.1.2. , , 9.6.1.2. , 9.6.1.4. , 9.8.8.7. , 9.9.4.3. 9.9.4.6. , 9.10.13.5. , 9.10.14.4. , 9.10.15.4.
Wires and cables, 3.1.4.3. , 3.1.5.21. , 3.6.4.2.
- electrical, 3.2.6.5. , 9.34. , 9.34.1.5.
- fire/smoke alarm, 3.2.4.10. , 3.2.7.10. , 9.10.19.4.
- fire separations, 3.1.9.3. , 9.10.9.6.
- noncombustible construction, 3.1.5.21. , 3.1.5.22.
- penetrating fire separations, 3.1.9.2.
- in plenums, 3.6.4.3.
- protection of electrical conductors, 3.2.7.10.
- storage, 3.3.6.2.
Wood
- bracing, 9.23.13.
- blocking, 3.1.5.2., 9.8.7.7., 9.23.3.4., 9.23.9.3., 9.23.9.4., 9.23.9.8., 9.23.10.2.
- cant strips, 3.1.5.3., 9.26.4.6., 9.26.4.7., 9.26.11.10.
- columns, 3.1.4.7., 9.10.14.5., 9.10.15.5., 9.17.4., 9.35.4.2.
- design and construction, 3.1.4.7., 9.23.
- design basis, 4.3.1., 9.4.
- dimensions, 9.3.2.6. - 9.3.2.8.
- door frames, 9.10.13.3.
- doors, 9.7.5.2.
- fire-resistance rating, 3.1.4.6., 9.10.6.2.
- fire-retardant treated, 1.4.1.2. [A], 3.1.4.5., 3.1.5.5., 3.1.5.12., 3.1.5.24., 3.1.13.8., 3.1.14.1., 3.2.2.25., 3.2.2.32., 3.2.2.62., 3.2.2.68., 3.2.2.79., 3.2.2.85.
- floor beams, 9.23.8.1.
- floor joists, 9.23.9.
- flooring, 9.30.3., 9.30.4.
- floors-on-ground, 9.16.5.
- floor supports, 3.1.4.7., 3.1.5.8., 9.23.4.1., 9.23.4.2., 9.23.4.4., 9.23.8.3., 9.30.1.3.
- flooring, 9.30.3., 9.30.4.
- foundations, 4.2.3.1., 4.2.3.2., 9.15.1.1., 9.15.2.4.
- in heavy timber construction, 3.1.4.7.
- in noncombustible construction, 3.1.5.2., 3.1.5.3., 3.1.5.5., 3.1.5.8., 3.1.5.10.
- lockers, 3.1.5.17.
- preservative treatment, 4.2.3.2., 9.3.2.9., 9.8.9.3., 9.23.2.2., 9.23.2.3., 9.30.1.3.
- products, 9.3.2.
- roofs, 3.1.4.7., 3.1.14.1., 9.23.4.1., 9.23.4.2., 9.23.4.5., 9.23.16.
- shingles and shakes, 9.26.2.1., 9.26.2.3., 9.26.3.1., 9.26.9., 9.26.10., 9.27.7.
- siding, 9.27.6., 9.27.7., 9.27.8., 9.27.9., 9.27.10., 9.10.14.5., 9.10.15.5.
- stairs, 9.8.9.3. - 9.8.9.6.
Wood blocking
- cladding, 9.23.10.5., 9.27.5.2.
- doors, 9.7.5.2.
- with handrails, 9.8.7.7.
- interior finishing materials, 9.23.10.5.
- joists, 9.23.9.3., 9.23.9.4., 9.23.14.9.
- nailing, 9.23.3.4.
- in noncombustible construction, 3.1.5.2.
- rafters and joists, 9.23.14.7.
- roof edges, 9.23.16.6., 9.23.16.7.
- subflooring, 9.23.15.3.
- walls, 9.23.9.8., 9.23.10.2.
Wood burning appliances, (see also Solid fuel burning appliances)
- chimneys, (for), 9.21., 9.33.6.12., 9.33.6.13.
- chimney liners, 9.21.3.9., 9.22.2.3.
- chimneys and flues, 6.3.3.2., 6.3.3.3., 9.21.1.1., 9.21.2.1., 9.21.2.2., 9.33.10.1., 9.33.10.2.
- ducts serving, 3.6.5.8., 9.33.6.13.
- factory-built fireplaces, 9.22.1.4., 9.22.8.1.
- hearth-mounted stoves, 9.22.10.
- inserts and hearth-mounted stoves, 9.22.10.
- installation, 3.6.2.1.
- installation standard, 6.2.1.5., 9.22.10.2., 9.31.6.2., 9.33.5.3.
- location restrictions, 3.6.2.1.
- masonry fireplaces, 9.22.
- product standards, 9.22.2.3., 9.22.8.1., 9.22.10.1., 9.33.5.3.
- protection against depressurization, 9.32.3.8.
- return air (for), 6.3.2.11., 9.33.6.12., 9.33.6.13.
- venting, 6.3.3.1., 9.33.10.1.
Wood-frame construction
- alternative structural components, 9.23.1.1.
- beams to support floors, 9.23.8.
- bracing for earthquake and wind loads, 9.23.13.
- fasteners and connectors, 9.23.3.
- floor joists, 9.23.9.
- framing over openings, 9.23.12.
- housing and small buildings, 9.23.
- maximum spans, 9.23.4.
- notching and drilling, 9.23.5.
- roof and ceiling framing, 9.23.14.
- roof sheathing, 9.23.16.
- sill plates, 9.23.7.
- subflooring, 9.23.15.
- wall plates, 9.23.11.
- wall sheathing, 9.23.17.
- wall studs, 9.23.10.
Wood products
Y
- Yard, as access for firefighters, 3.2.5.6. , 9.10.20.3.
Yoke vent, 7.5.1.1. ., 7.5.4.3. , 7.5.4.5. , 7.5.7.5.
- definition, 1.4.1.2. [A]
Z
- Zinc, alloyed, 7.2.10.14.